Brand: Trafag Sensors & Controls

Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature.
Features
  • Compact design
  • Rugged housing
  • Protection IP65
  • Any mounting position possible

1 - 12 of 1,536 Part Numbers
409 10 02 422.27.2743.0215
409 10 02 422.27.2743.0215
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Without Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Without Outdoor Application
409 10 02 422.27.2743.0215 14
409 10 02 422.27.2743.0215 14
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Without Outdoor Application
409 10 02 422.27.2743.0215 14 28
409 10 02 422.27.2743.0215 14 28
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Version - Railway Version IEC 61373, Category 2
  • Application - Without Outdoor Application
409 10 02 422.27.2743.0215 14 28 44
409 10 02 422.27.2743.0215 14 28 44
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Version - Railway Version IEC 61373, Category 2
  • Application - Outdoor Application (Vented)
409 10 02 422.27.2743.0215 14 44
409 10 02 422.27.2743.0215 14 44
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Outdoor Application (Vented)
409 10 02 422.27.2743.0215 28
409 10 02 422.27.2743.0215 28
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Without Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Railway Version IEC 61373, Category 2
  • Application - Without Outdoor Application
409 10 02 422.27.2743.0215 28 44
409 10 02 422.27.2743.0215 28 44
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Without Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Railway Version IEC 61373, Category 2
  • Application - Outdoor Application (Vented)
409 10 02 422.27.2743.0215 44
409 10 02 422.27.2743.0215 44
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Without Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Outdoor Application (Vented)
409 10 02 423.27.2743.0215
409 10 02 423.27.2743.0215
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper Nickel-Plated / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Without Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Without Outdoor Application
409 10 02 423.27.2743.0215 14
409 10 02 423.27.2743.0215 14
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper Nickel-Plated / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Without Railway Version
  • Application - Without Outdoor Application
409 10 02 423.27.2743.0215 14 28
409 10 02 423.27.2743.0215 14 28
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper Nickel-Plated / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Switchpoint - Without Switchpoint Locking
  • Version - Railway Version IEC 61373, Category 2
  • Application - Without Outdoor Application
409 10 02 423.27.2743.0215 14 28 44
409 10 02 423.27.2743.0215 14 28 44
  • Custom Build Code - External Adjustment
  • Microswitch - Small Switching Differential, Not Adjustable
  • Temperature Range - -30° to 30° C (-22° to 86° F)
  • Sensor / Fixing - Copper Nickel-Plated / Bracket, with Protection Tube Length=215 mm, Steel Nickel-Plated
  • Signal - Signal Lamp
  • Version - Railway Version IEC 61373, Category 2
  • Application - Outdoor Application (Vented)
1 - 12 of 1,536 Part Numbers

Specifications

Accuracy

  • ± 2 % of Full Scale - Typical

Applications

  • HVac Systems
  • Industrial Room Thermostat

Approvals & Certifications

  • EN 60730-1, EN 60730-2-9

Electrical Connectors

  • Cable Gland: M20 x 1.5
  • Terminal Screw: 3 x 1 to 2.5 mm²

Electrical Rating

  • 0.1 (0.1) A at 24 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 0.2 (0.02) A at 250 Vdc for Small Switching Differential, Not Adjustable
  • 0.25 (0.03) A at 250 Vdc for Average, Standard Adjustable Switching Differential
  • 0.4 (0.03) A at 125 Vdc for Small Switching Differential, Not Adjustable
  • 0.5 (0.05) A at 125 Vdc for Average, Standard Adjustable Switching Differential
  • 1 (1) A at 12 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 10 (0.75) A at 500 Vac for Average, Standard Adjustable Switching Differential
  • 10 (1.25) A at 250 Vac for Small Switching Differential, Not Adjustable
  • 10 (1.5) A at 125 Vac for Small Switching Differential, Not Adjustable
  • 15 (1.25) A at 250 Vac for Average, Standard Adjustable Switching Differential
  • 15 (1.5) A at 125 Vac for Average, Standard Adjustable Switching Differential
  • 15 (2.5) A at 14 Vdc for Small Switching Differential, Not Adjustable
  • 2 (1) A at 30 Vdc for Small Switching Differential, Not Adjustable
  • 2 (2) A at 5 Vac/Vdc for Gold-Plated Contacts, Not Adjustable
  • 6 (1.5) A at 30 Vdc for Average, Standard Adjustable Switching Differential

Enclosure, Body Material

  • Aluminum (AlSi9Cu3) Coated

Environmental Protection

  • IP65

Fill Material

  • Liquid

Gland Material

  • Screwed Cable Gland: Brass Nickel-Plated

Humidity

  • Maximum

Insulation Resistance

  • > 2 megaohms

Measuring Range

  • -30° to 60° C (-22° to 140° F)

Mounting Position

  • Any Orientation

Operating Temperature

  • -30° to 70° C (-22° to 158° F)

Repeatability

  • ± 0.5 % of Full Scale - Typical

Sensor, Probe Material

  • Sensor: Copper
  • Sensor: Nickel-Plated

Set Point - Decreasing

  • -30° to 60° C (-22° to 140° F)

Set Point - Increasing

  • -30° to 60° C (-22° to 140° F)

Storage Temperature

  • -30° to 85° C (-22° to 185° F)

Voltage

  • Dielectric Strength: 1.45 kV (U ≤ 250 V)
  • Dielectric Strength: 2 kV (U ≤ 500 V)

  • HVAC