Yodify Product Library
Add the Model 7720 Cryogenic Pressure Transducer to your store or catalog
Book Your Demo and See How
or create your store
Model 7720 Cryogenic Pressure Transducer
Brand: GP:50 New York Ltd
Features
- Output Signal: 0 to 5 Vdc, 0 to 10 Vdc, 4-20 mA
- Supply Voltage: 18 to 36 Vdc
- Pressure Range: 0 to 5,000 psi (0 to 344.7 bar, 0 to 34,474 kPa)
- Burst Pressure: 2 times range
- Proof Pressure: 1.5 times range
- Electrical Connections: MIL PTIH-10-6P
- Process Connection: AS4395E04
- Temperature Range:
- Process: -196° to 129°C (-320° to 265°F)
- Ambient: -40° to 85°C (-40° to 185°F)
- Compensated: -196° to 21.1°C (-320° to 70°F)
- Effect on Zero/Span:
- ±1.0% FSO at 100 °F for ranges >1,000 psi
- ±2.0% FSO at 100 °F for ranges <1,000 psi
- Static Accuracy: ±0.3% Full ScaleO
- Materials of Construction:
- Housing: 316 Stainless Steel
- Wetted Parts: 17-4 Stainless Steel
- Flex Tubing: 18" Armoured flex capillary tube
1 - 1 of 1 Part Numbers
1 - 1 of 1 Part Numbers
Specifications
Brand
Accuracy
- < ± 0.3 % of FSO
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Burst Pressure
- 2 x FSO
Circuit Protection
- EMI/RFI Protected
- Meets MIL-STD-461/462
Compensated Temperature
- -196° to 21° C (-320° to 70° F)
Electrical Connectors
- Bendix PTIH-10-6P
Enclosure, Body Material
- 316 Stainless Steel
Hysteresis
- < ± 0.2 % of FSO
Independent Linearity
- < ± 0.2 % of FSO
Output
- 0-10 Vdc
- 0-5 Vdc
- 4-20 mA
Pressure Range
- bar: 10 to 207
- kPa: 0 to 34,473
- psi: 0 to 5,000
Pressure Type
- Absolute
- Gauge
Process Temperature
- -196° to 129° C (-320° to 265° F)
Proof Pressure
- 1.5 x FSO
Repeatability
- < ± 0.1 % of FSO
Response Time
- < 4 ms
Span & Zero Effect
- < ± 2.0 % of FSO at 38° C (100° F)
- ± 1.0 % of FSO at 38° C (100° F)
Supply Voltage
- 18 V to 36 Vdc
- 9 to 36 Vdc
Wetted Materials
- 630 Stainless Steel