GPL 10000 Odorization System

Brand: GPL Odorizers

The GPL 10000 is intended for high-pressure and high-volume applications at transmission companies and large city gate stations. 

The odorizer has high rangeability, achieving precision odorization over a wide operating range of volume. 

The industry-leading programmable logic controller (PLC) interfaces with the flow meter and its system components to maintain constant odorant injection proportional to the gas flow rate.
Features
A closed-loop system means no gas or odorant discharges to atmosphere
  • No smell during operation and maintenance
  • Lowers false leak calls and complaints
  • Eco-friendly; better for the environment
Does not use gas to actuate the system
  • Saves pipeline gas
Continuous odorant injection proportional to the gas flow rate
  • Eliminates under or over-odorization issues
  • Accurate and reliable odorant injection
High rangeability (100:1 turndown ratio)
  • Odorization over a wide range of flows
Few moving parts
  • Simple operation
  • Low maintenance
  • Long-lasting performance
  • No smelly pneumatic pumps to replace or maintain
Dual stroke electric-powered bellows pump
  • Back up if one pump ever fails
Modular solid-state manifold
  • Easy to replace and work on
Industry-leading PLC with large (7”), intuitive, color touchscreen and SD card data storage (Spanish mode available upon request)
  • Easy to learn and operate
  • The data stores on PLC SD Card permitting accessible audit-trail reports for regulatory or company inspections
  • Communicates real-time critical alarms and soft alarms (maintenance reminders)
  • Allows for Modbus (SCADA)
PLC Interfaces with SCADA Systems
  • SCADA systems save time and energy, increase reliability, reduces cost, improves worker safety, higher customer satisfaction, and improves utilization.
Wireless modem
  • Remote communication (using a wireless modem or Modbus) permits real-time mobile alerts and online monitoring to mobile phones and computers to prevent small problems from becoming big ones and speeds up restoration time.
Easy-to-use software provided
  • No additional software required
Class I Division 2, Groups C and D
  • Adheres to standards

Specifications

Weight

  • 194 lb (88 kg)

Power

  • Typical: 24 Vdc, 0.036 HP, 27.05 W
  • Maximum: 24 Vdc, 0.193 HP, 124.8 W
  • Optional: AC

Gas Pipeline Pressure

  • Up to 1480 psi (102 bar)

Odorant Blanket Pressure

  • 20 psi (1 to 2 bar)

Data Logging

  • Hourly archives with audit trail, FTP data retrieval, internal micro SD storage

Enclosure

  • 304 Stainless Steel

Hazardous Area Classification

  • Class I, Div. 2, Groups C and D

Overall Dimensions

  • 32½” (H) x 25⅝” (W) x 10⅞” (D), 82.55 cm x 65.09 cm x 27.62 cm

Odorant Injection Rate, Continuous

  • From 2.4 MMSCFD to 240 MMSCFD(at an injection rate of 0.5 lb/MMSCFH)

Odorant Injection Rate, Batch

  • From 480 MSCFD to 2.4 MMSCFD(at an injection rate of 0.5 lb/MMSCFH)

Connections

  • Myers hub: (2) ¾ in NPT, (1) ½ in NPT Odorant outlet, odorant return, odorant inlet: ¼ in comp

Operating Temperature Range

  • 0° to 140 ̊F (-18° to 60° C)
  • Optional: Heater assembly available for below 0° F (-18° C)

User Interface Options

  • 320 x 240 LCD Color Graphics Display with Touch Screen
  • IP Remote Communication

Documentation