Yodify Product Library
Instantly add the Model 2001RS Oxygen Analyzer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Model 2001RS Oxygen Analyzer
Brand: Advanced Micro Instruments, IncThe AMI model 2001RS is the ideal solution for measuring trace oxygen in a wide range of applications in a general-purpose environment.
In a compact size, and at low cost, it provides a comprehensive electronic package and sample system using AMI’s patented cell block technology.
In addition the 2001RS uses internal surface mount solenoid valves for sample/span gas selection and to seal off the sensor in the event of loss of power.
Unlike competitive analyzers, AMI sensor replacement requires minimal downtime due to the front panel sensor access and the patented AMI cell block.
Typical time from a one minute air exposure to 10 ppm is under 15 minutes.
Trace oxygen analyzers are essentially leak detectors.
AMI’s patented cell block allows the analyzer to be built with almost no possibility of internal leaking, with minimal volume and with front-panel sensor access.
All sample handling components – the flow meter, needle valve and the surface mount span/sample selection and seal-off solenoid valves – are integrated into two solid metal blocks.
The result is a highly reliable sample system with all necessary components provided, and a very fast “come-down” time.
When a sensor is replaced, or calibrated on air with a 1 minute exposure (at 70° F), it takes about 15 minutes for it to come down to below 10 ppm.
Competitive analyzers typically take hours. As a result, although a span gas port is provided, it is practical to accurately calibrate this analyzer on air and have it back on line within a very short time.
Features- 10 user selectable output ranges
- 3-1/2 digit LCD
- 2 fully adjustable oxygen concentration alarms
- Alarm hold off/Bypass
- RFI protected
- 4-20 mA isolated Analog output
- Analog output calibration synchronizes the Analog output with an external monitoring system
- Data logger
- Fully programmable alarm delays
Specifications
Enclosure, Body Material
- Metallic
Power Requirement
- 90-240 Vac < 10 W
Process Connection - Other
- 1/4” Stainless Steel Compression Fittings for Sample, Span Gas & Exhaust
Range
- 0 to 1 %
- 0 to 1,000 ppm
- 0 to 10 ppm
- 0 to 10 %
- 0 to 100 ppm
- 0 to 25 %
- 0 to 5 %
- 0 to 5,000 ppm
- 0 to 50 ppm
- 0 to 500 ppm
Repeatability
- ± 1 % of Full Scale at Constant Temperature
Sensitivity
- 0.5 % of Full Scale