Yodify Product Library
Instantly add the P341 Homogenizer Pressure Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
P341 Homogenizer Pressure Transmitter
Brand: Tel-Tru Manufacturing Co.Key feature of the P341 is its non oil – filled sensing element. The sensing diaphragm is machined from a solid piece of steel, and can withstand the most abrasive / cyclical applications.
Tel-Tru developed this product to last in high cyclical environments with or without the presence of water - hammering or spiking.
Advanced manufacturing techniques, extreme environmental burn-in and thorough residual stress relieving procedures ensure the P341 maintains its performance over time.
Specifications
Accuracy
- Static Accuracy: ± 0.5 % of Full Scale Output (BFSL, RSS) Combined Effects of Non-Linearity, Hysteresis & Repeatability,
- Static Accuracy: ≤ 0.25 % of Full Scale Output
Applications
- Biotechnology
- Cosmetics
- Dairy Processing
- Food & Beverage Processing
- Pharmaceutical
Burst Pressure
- 5 times Full Scale, Max.
Compensated Temperature
- -17.8° to 76.7° C (0° to 170° F)
Electrical Connectors
- 3/8” NPT Male Conduit Connection with 2 to 50 feet Wire Pigtail
- 6-Pin Bendix
- NEMA 4X Cable Exit [24” (610 mm) Cable]
- Pigtail Connector (2, 5, 10 feet Wire)
Electrical Protection
- Short Circuit Protected: up to 40 Vdc - P341A, P341B
Environmental Protection
- IP66
- NEMA 4X
Excitation Voltage
- 2-15 Vdc - P341C
- 8-38 Vdc - P341A / P341B
Insulation Resistance
- 1,000 megaohms at 50 Vdc
Materials of Construction
- Non-Wetted Part: 316 Stainless Steel & Electrical Connector
NACE & NIST
- NIST Traceable Calibration Certificate
Operating Temperature
- -40° to 93° C (-40° to 200° F)
Output
- 0-5 Vdc, 3-Wire - P341B
- 1-2 mV/V (4-Wire) - P341C
- 4-20 mA, 2-Wire - P341A
Power Supply Effect
- ± 0.002 % of Full Scale Output Per V Input - P341A, P341B
Pressure Range
- bar: 0 to 1,379
- kPa: 0 to 137,900
- psi: 0 to 20,000
Pressure Type
- Sealed Gauge
Process Fitting Details
- Homogenizer Fitting
Proof Pressure
- 2 x Full Scale
Repeatability
- ± 0.1 % of Full Scale Output
Resolution
- Infinite (± 0.001 % of Full Scale Output Usable)
Response Time
- < 0.5 millisecond - P341C
- < 3 milliseconds - P341A / P341B
Reverse Polarity Protection
- Yes
RFI/EMI Protection
- Internal Filtering - P341A, P341B
Stability
- Long Term Stability: ± 0.25 % of Full Scale Output Per Year
Storage Temperature
- -40° to 121° C (-40° to 250° F)
Temperature Effect
- ± 1.5 % of Full Scale Output over Compensated Range [Combined Effects of Zero & Full Scale Output with Reference at 21° C (70° F)]
Wetted Materials
- 632 Stainless Steel (15-5)
- Hastelloy C-276
Zero Balance
- ± 1 % of Full Scale Output