Yodify Product Library
Add the GMS800 Extractive Gas Analyzer to your store or catalog
Book Your Demo and See How
or create your store
GMS800 Extractive Gas Analyzer
Brand: Sick AGThe GMS800 is a product family of extractive analyzers which can measure more than 60 different gas compounds.
The GMS800 is characterized by its modular design: 6 analyzing modules, one gas module, I/O modules and an operating unit. Standardized 19" racks can be used for economic system integration.
Wall mounting enclosures with an ATEX approval for hazardous areas can be used in rough industrial environments.
Equipped with modern software, the GMS800 comes with the required interfaces for remote control via networks through to the connection to a process control system.
Features- Approved according to EN 15267 and EN 14181
- Installations in Non-Ex-areas and Ex-areas (Zone 1 and 2 according to ATEX) possible
- Minimum service and maintenance work as well as easy reconditioning of existing installations due to modular design
- Adjustment without test gases via optional adjustment unit
- Minimal influence of ambient temperature through thermostatic controlled modules
- Reliable measuring results by proven measurement technology
- Easy maintenance and repair due to replacement of complete assemblies or modules
Specifications
Brand
Certifications & Approvals
- CE
- MCERTS
- NEC/CEC (US/CA)
- IECEx
- cCSAus
- ATEX
Enclosure Rating
- IP65
- IP40
- IP20
- IP66/NEMA 4X
Measured Value
- Ar, CH₄, CH3OH, C₂H₂, C₂H₂F₄, C₂H₄, C3H₆, C3H8, C4H₆, Cl2, CO, CO₂, COCl2, COS, CS2, H₂, H₂S, He, NH₃, NO, N₂O, NO₂, O₂, SF6, SO₂
Gas Flow Rate
- 30 to 60 L/h
Sample Gas Temperature
- Analyzer Inlet 0° to 45° C
Process Pressure
- Tube Gas Lines: -200 to 1,000 hPa
- Hosed Gas Lines: -200 to 300 hPa
Ambient Temperature
- 5° to 45° C
Storage Temperature
- -20° to 70° C
Ambient Pressure
- 700 to 1,200 hPa
Humidity
- 20 % to 90 % RH, Non-Condensing
Power Supply
- GMS810, GMS811, GMS820P: 93-132 Vac, 186-264 Vac, 210-370 Vac, 47 to 63 Hz, Power Consumption ≤ 300 VA
- GMS840: 85-264 Vac, 47 to 63 Hz, Power Consumption ≤ 300 VA, Current Consumption ≤ 10 A
Documentation
Data Sheets
Product Manuals
- Analyzer Module DEFOR For Series Gms800 Addendum To Operating Instructions pdf 573 KB
- Flammable Gases / Brennbare Gase Addendum To Operating Instructions pdf 243 KB
- GMS 800 Operating Instructions pdf 925 KB
- GMS800 - Analyzer Module Thermor Addendum To Operating Instructions pdf 513 KB
- GMS800 - Analyzer Module OXOR-E Addendum To Operating Instructions pdf 589 KB
- GMS800 - Analyzer Module OXOR-P Addendum To Operating Instructions pdf 492 KB
- GMS800 - Analyzer Module Unor-Multor Addendum To Operating Instructions pdf 487 KB
- GMS800 - Enclosure GMS810 / GMS811 Addendum To Operating Instructions pdf 430 KB
- GMS800 - Enclosure GMS815P / GMS815P-3G Addendum To Operating Instructions pdf 613 KB
- GMS800 - Enclosure GMS815P / GMS815P-3G Addendum To Operating Instructions pdf 243 KB
- GMS800 - Enclosure GMS820P Addendum To Operating Instructions pdf 366 KB
- GMS800 - Enclosures GMS815P-PS-2G / GMS815P-PS-3G Addendum To Operating Instructions pdf 726 KB
- GMS800 - Gas Module Addendum To Operating Instructions pdf 243 KB
- GMS800 - I/O Module Addendum To Operating Instructions pdf 589 KB
- GMS800 BCU - Basic Control Unit Addendum To Operating Instructions pdf 2.3 MB
- GMS800 Ex - Safety Information For Ex Devices pdf 2.0 MB
- GMS840 - Enclosure For GMS800 Series Addendum To Operating Instructions pdf 2.1 MB
- Safety Information For Non-Ex Analyzers pdf 2.8 MB