SP30-H & SP35-H Electrically Heated Probe Tube
Brand: M&C TechGroup Germany GmbHThe electrically heated M&C sample probe tube SP30/35-H is used in extractive sampling systems to avoid cooling and condensation of the sample in the insitu tube from the sample point to the heated sample probe SP2000-H.
To avoid a premature damage by cooling and condensation in dust loaded processes, we recommend a heated tube type SP30-H1.1-V, including an insitu pre-filter V20-2/30, heated up with the tube.
Features- Completely heated sample tube
- Different lengths
- Unheated pre-filters or extensions possible
- Simultaneously heated pre-filter possible
- Easy mounting
- Two temperature sensor versions
1 - 12 of 18 Part Numbers
+ 02S9036
- Version - SP35-H1.1
- Power Supply - 115 Vac
02S9023
- Version - SP30-H1.1
- Length - 600 mm
02S9023P
- Version - SP30-H2
- Length - 600 mm
02S9024
- Version - SP30-H1.1
- Length - 2,000 mm
02S9024P
- Version - SP30-H2
- Length - 2,000 mm
02S9025
- Version - SP30-H1.1
- Length - 1,000 mm
02S9025P
- Version - SP30-H2
- Length - 1,000 mm
02S9026
- Version - SP30-H1.1
- Length - 1,500 mm
02S9026P
- Version - SP30-H2
- Length - 1,500 mm
02S9037
- Version - SP30-H1.1-V
- Length - 600 mm
02S9038
- Version - SP30-H1.1-V
- Length - 1,000 mm
02S9092
- Version - SP30-H1.1/HC
- Length - 1,000 mm
1 - 12 of 18 Part Numbers
Specifications
Ambient Temperature Range
- -20° to 80° C (-4° to 176° F)
Approvals & Certifications
- Electrical Standard: EN 61010, EN 60519-1
BSP Connection
- Sample Gas Inlet Connection: G 3/4”i DIN ISO 228/1 - Version SP35-H1.1, H2, SP30-H1.1, H2
- Sample Gas Inlet Connection: Pre-Filter with G1-1/2”i DIN ISO 228/1 - Version SP30-H1.1-V
Capacity
- Heating Capacity: 200 W - Version SP35-H1.1, H2
- Heating Capacity: 600 to 1,200 W - Version SP30-H1.1, H2, H1.1-V
Differential Pressure
- ∆P Pressure Loss SP30-H Length 1 Meter, ∆P Pressure Loss SP30-H-V Length 1 Meter with New Pre-Filter V20-2/30 < psi: 0.014 to 0.058 (kPa: 0.1 to 0.4, Mbar: 1 to 4)
Electrical Connectors
- 2 x PG 13.5 Cable Gland
- Terminals, Max.
Environmental Protection
- IP54 EN 60529
Flange Size - 2-1/2” (DN 65)
- 2-1/2” (DN 65) - PN 6 (Form B)
Flow Rate
- ∆P & T90 at Flow: 100 to 1,000 NL/hr
Materials of Construction
- 904L Stainless Steel (1.4539) - Version SP30-H1.1-V
- Material of Parts in Contact with the Sample: 316 Stainless Steel
- Material of Parts in Contact with the Sample: 316Ti Stainless Steel
- Material of Parts in Contact with the Sample: Hastelloy C - Version SP30-H1.1/HC
Mounting
- Flange Mount
- Mounting Flange: 4 Welded Screws on Both Sides M12 x 40 mm
Operating Temperature
- 200° to 320° C (392° to 608° F)
Power Supply
- 115 Vac
- 230 Vac
Pressure Range
- Sample Pressure, Max.
Response Time
- T90-Time: < 2 to 14 seconds
Sensor, Probe Length
- Probe Tube Length L1: 6.88” (175 mm) - Version SP35-H1.1, H2
- Probe Tube Length L1: Max.
Sensor, Probe Type
- J-Typical (Fe-CuNi) - Version SP35-H1.1, SP30-H1.1, SP30-H1.1-V
- Pt100 2 - Version SP35-H2, SP30-H2
Storage Temperature
- -30° to 90° C (-22° to 194° F)