Yodify Product Library
Instantly add the SP30-H & SP35-H Electrically Heated Probe Tube and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

SP30-H & SP35-H Electrically Heated Probe Tube

Brand: M&C TechGroup Germany GmbH

The electrically heated M&C sample probe tube SP30/35-H is used in extractive sampling systems to avoid cooling and condensation of the sample in the insitu tube from the sample point to the heated sample probe SP2000-H. 

To avoid a premature damage by cooling and condensation in dust loaded processes, we recommend a heated tube type SP30-H1.1-V, including an insitu pre-filter V20-2/30, heated up with the tube.
Features
  • Completely heated sample tube
  • Different lengths
  • Unheated pre-filters or extensions possible
  • Simultaneously heated pre-filter possible
  • Easy mounting
  • Two temperature sensor versions

1 - 12 of 18 Part Numbers
+ 02S9036
+ 02S9036
  • Version - SP35-H1.1
  • Power Supply - 115 Vac
02S9023
02S9023
  • Version - SP30-H1.1
  • Length - 600 mm
02S9023P
02S9023P
  • Version - SP30-H2
  • Length - 600 mm
02S9024
02S9024
  • Version - SP30-H1.1
  • Length - 2,000 mm
02S9024P
02S9024P
  • Version - SP30-H2
  • Length - 2,000 mm
02S9025
02S9025
  • Version - SP30-H1.1
  • Length - 1,000 mm
02S9025P
02S9025P
  • Version - SP30-H2
  • Length - 1,000 mm
02S9026
02S9026
  • Version - SP30-H1.1
  • Length - 1,500 mm
02S9026P
02S9026P
  • Version - SP30-H2
  • Length - 1,500 mm
02S9037
02S9037
  • Version - SP30-H1.1-V
  • Length - 600 mm
02S9038
02S9038
  • Version - SP30-H1.1-V
  • Length - 1,000 mm
02S9092
02S9092
  • Version - SP30-H1.1/HC
  • Length - 1,000 mm
1 - 12 of 18 Part Numbers

Specifications

Ambient Temperature Range

  • -20° to 80° C (-4° to 176° F)

Approvals & Certifications

  • Electrical Standard: EN 61010, EN 60519-1

BSP Connection

  • Sample Gas Inlet Connection: G 3/4”i DIN ISO 228/1 - Version SP35-H1.1, H2, SP30-H1.1, H2
  • Sample Gas Inlet Connection: Pre-Filter with G1-1/2”i DIN ISO 228/1 - Version SP30-H1.1-V

Capacity

  • Heating Capacity: 200 W - Version SP35-H1.1, H2
  • Heating Capacity: 600 to 1,200 W - Version SP30-H1.1, H2, H1.1-V

Differential Pressure

  • ∆P Pressure Loss SP30-H Length 1 Meter, ∆P Pressure Loss SP30-H-V Length 1 Meter with New Pre-Filter V20-2/30 < psi: 0.014 to 0.058 (kPa: 0.1 to 0.4, Mbar: 1 to 4)

Electrical Connectors

  • 2 x PG 13.5 Cable Gland
  • Terminals, Max.

Environmental Protection

  • IP54 EN 60529

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - PN 6 (Form B)

Flow Rate

  • ∆P & T90 at Flow: 100 to 1,000 NL/hr

Materials of Construction

  • 904L Stainless Steel (1.4539) - Version SP30-H1.1-V
  • Material of Parts in Contact with the Sample: 316 Stainless Steel
  • Material of Parts in Contact with the Sample: 316Ti Stainless Steel
  • Material of Parts in Contact with the Sample: Hastelloy C - Version SP30-H1.1/HC

Mounting

  • Flange Mount
  • Mounting Flange: 4 Welded Screws on Both Sides M12 x 40 mm

Operating Temperature

  • 200° to 320° C (392° to 608° F)

Power Supply

  • 115 Vac
  • 230 Vac

Pressure Range

  • Sample Pressure, Max.

Response Time

  • T90-Time: < 2 to 14 seconds

Sensor, Probe Length

  • Probe Tube Length L1: 6.88” (175 mm) - Version SP35-H1.1, H2
  • Probe Tube Length L1: Max.

Sensor, Probe Type

  • J-Typical (Fe-CuNi) - Version SP35-H1.1, SP30-H1.1, SP30-H1.1-V
  • Pt100 2 - Version SP35-H2, SP30-H2

Storage Temperature

  • -30° to 90° C (-22° to 194° F)
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more