Yodify Product Library
Instantly add the ADS550 Dissolved Oxygen Analyzer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
ADS550 Dissolved Oxygen Analyzer
Brand: ABB GroupThe Navigator 500 dissolved oxygen analyzer provides continuous monitoring and control of dissolved oxygen levels in steam-raising and desalination plants and semiconductor water treatment.
Featuring a separate sensor section and transmitter, the Navigator 500 Dissolved Oxygen gives users the option of adding up to four wet-sections to one transmitter, enabling measurement of samples from different measuring points.
This not only offers an economic and compact solution, but allows operators to mix and match other parameters within the Navigator 500 range to reduce installation footprint and cost.
Features- Maintenance-free dissolved oxygen sensor removes the need for membrane changes or electrolyte replenishment
- Automatic calibration minimizes manual intervention and ensures accuracy
- Fast response time allows control of rapid changes in plant conditions
- Intuitive software with full color graphical display
- Data logging and graphical process trending
- Full audit trail capability
- Secure data archiving to SD Card or USB Stick
1 - 12 of 400 Part Numbers
ADS550/A1W1S1A1 CDM1
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - German
ADS550/A1W1S1A1 CDM2
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - Italian
ADS550/A1W1S1A1 CDM3
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - Spanish
ADS550/A1W1S1A1 CDM4
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - French
ADS550/A1W1S1A1 CDM5
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - English
ADS550/A1W1S1A1 M1
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - None (Not Required)
- Manual - German
ADS550/A1W1S1A1 M2
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - None (Not Required)
- Manual - Italian
ADS550/A1W1S1A1 M3
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - None (Not Required)
- Manual - Spanish
ADS550/A1W1S1A1 M4
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - None (Not Required)
- Manual - French
ADS550/A1W1S1A1 M5
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - None (Not Required)
- Signal Cable Length - None (Not Required)
- Test Certificate - None (Not Required)
- Manual - English
ADS550/A1W1S1A1 S1CDM1
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - Sample Flow Measurement
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - German
ADS550/A1W1S1A1 S1CDM2
- Measurement Tange - Standard (0 to 20,000 ppb)
- Enclosure Type - Wall
- Number of Streams - Single Stream
- Sensor Type - Standard
- Process Connection Type - 6 mm Fitting
- Sample Measurement Option - Sample Flow Measurement
- Signal Cable Length - None (Not Required)
- Test Certificate - Test Certificate
- Manual - Italian
1 - 12 of 400 Part Numbers
Specifications
Brand
Measurement Range
- 0 to 20,000 ppb
Accuracy
- ± 5 % of Reading or ± 1 ppb, whichever is greater
Repeatability
- ± 3 % of Reading or ± 1 ppb, whichever is greater
Response Time
- 1 minute for a 90 % step change
Resolution
- 0.1 ppb
Sample Temperature
- 5° to 55° C (41° to 131° F)
Sample Pressure
- 2 bar gauge (29 psi) Max.
Flow Rate
- Sample: 100 to 300 mL/min
Process Connection
- Sample: 1/4” or 6 mm O.D. pipe
Operating Temperature
- 0° to 55° C (32° to 131° F)
Storage Temperature
- 0° to 55° C (32° to 131° F) with Sensor
- -20° to 70° C (-4° to 158° F) without Sensor
Humidity
- Up to 95 % Relative Humidity, Non-Condensing
Certifications & Approvals
- LV Directives
- EMC
- CE
- cULus
Environment Protection
- IP54
Power Supply
- 24 Vdc Max.
Power Consumption
- 8 W Max.
Display
- 89 mm (3.5 in) color 1/4 VGA TFT, LCD with built-in backlight and brightness / Contrast Adjustment
- Protection against corrosion caused by excessive dissolved oxygen concentrations
- Deaerator Efficiency Indication
- Hydrazine Dosing Efficiency Indication
Documentation
Brochure
Manual
- Addendum - RoHS Directive | 2011/65/EU (RoHS II) pdf 556 KB
- Commissioning instruction - Navigator 540 | Transmitter pdf 4.0 MB
- Commissioning instruction - Navigator 550 Low level dissolved oxygen wet-section pdf 678 KB
- Communications supplement - Navigator AWT540 | Transmitter pdf 2.1 MB
- Operating instruction - Navigator 500 | Low level dissolved oxygen analyzer pdf 8.5 MB
- Instruction - Replacement procedure | Navigator ADS551 | Low level dissolved oxygen | Replacement / Upgrade procedures – wet section spares pdf 1.3 MB