Brand: ABB Group

The pH / Redox (ORP) Analyzer AX460 is used with glass, enamel and antimony pH electrodes and metal redox sensors providing measurements with exceptional accuracy and performance. 

It incorporate the latest technology to provide a highly reliable, yet flexible, feature-packed device that satisfies a diverse range of process monitoring and control applications. 

Applications include water and waste-water treatment and process lines in Water, Power, Chemicals, Pharmaceuticals, Pulp & Paper and Food & Beverage industries.
Features
  • Cost effective
    • select one or two pH/Redox (ORP) inputs or combine pH/Redox (ORP) and conductivity in one analyzer
  • Reduced installation cost
    • easy access terminations; reduced panel space
  • High functionality at minimum cost
    • three alarms and two fully isolated current outputs
    • integral water / chemical sensor cleaner control
    • integral PID controller
  • Expanded monitoring and control
    • add-on option board provides a total of five alarm relays and four current outputs
    • service logbook providing historical data
  • On line assurance of reliability
    • comprehensive sensor and instrument self-checking
  • Energy saving
    • high visibility, backlit display with auto switch-off function
  • Reduced yearly maintenance costs
    • 12 to 30 V DC option negates the need for costly safety tests

1 - 12 of 90 Part Numbers
AX46010001
AX46010001
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46010002
AX46010002
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46010003
AX46010003
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46010101
AX46010101
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46010102
AX46010102
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46010103
AX46010103
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Basic (2 Current Outputs + 3 Relays)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011001
AX46011001
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011002
AX46011002
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011003
AX46011003
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 100 to 240 Vac 50/60 Hz
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011101
AX46011101
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - English
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011102
AX46011102
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - French
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
AX46011103
AX46011103
  • First Process Variable (PV1) - pH/Redox (ORP)
  • Second Process Variable (PV2) - No Second Process Variable - Select for PID Control of PV1
  • Enclosure Type - Wall-Mount IP65, General
  • Advanced Functions & Communications - Advanced (4 Current Outputs + 5 Relays + Logbook)
  • Power Supply - 12 to 30 Vdc
  • Manual - Italian
  • Wall-Mount IP65, General - Wall-Mount - Cable Glands Fitted
1 - 12 of 90 Part Numbers

Specifications

Brand

Range

  • -2 to 16 pH
  • -1200 to +1200 mV

Span

  • Any 2 pH Span or 100 mV min.

Resolution

  • 0.01 pH

Accuracy

  • 0.01 pH

Temperature Sensor

  • Programmable Pt100, Pt1000 or Balco 3 kΩ

Display

  • Dual 5-digit, 7-segment backlit LCD

Communication

  • PROFIBUS DP

Controller Type

  • P, PI, PID (Configurable)

Mounting

  • Pipe Mounting
  • Panel Mounting
  • Wall Mounting

Power Supply

  • 12-30 Vdc
  • 100-240 Vac, 50/60 Hz (90-264 Vac)

Power Consumption

  • 10 W

Operating Temperature

  • -20° to 55° C (-4° to 131° F)

Storage Temperature

  • -25° to 75° C (-13° to 167° F)

Humidity

  • Up to 95 % Relative Humidity Non-Condensing

Certifications & Approvals

  • CE
  • UL
  • EMC
  • LV Directives

  • Water and Waste Water Treatment
  • Power, Pure Water
  • Semiconductors
  • Chemicals
  • Pharmaceuticals
  • Pulp & Paper
Instantly populate your store or catalog 