Yodify Product Library
Instantly add the MultiHop Modbus I/O Data Radio and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
MultiHop Modbus I/O Data Radio
Brand: Banner EngineeringMultiHop Modbus Data Radios extend the range of Modbus or other serial communication networks.
Each radio may be set to act as either a master, repeater or slave.
Models are available with built in discrete and Analog I/O, which can be accessed using the Modbus protocol.
Features- Self-healing, auto routing RF network with multiple hops extends the networkās range.
- Flexible: dip switch selectable to be a master, repeater or slave.
- User-selectable communication between RS-485 and RS-232.
1 - 12 of 48 Part Numbers
DX80DR2M-DCLATCHE
- Device Type - Multihop
- Discrete Inputs - Yes
- Environmental Rating (IP) - IP65
- Environmental Rating (NEMA) - NEMA 4x
- Feature: Hazardous Area - No
- Housing Style - Enclosed Terminals
- Input Details - 2 Selectable Discrete; 2 Event Counters
- Input/output - Discrete
- Max Operating Temperature ( °C) - 65
- Min Operating Temperature ( °C) - -20
- Modbus RTU - No
- Output Details - DC Latch
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H
- Device Type - Multihop
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - Enclosed Terminals
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-232 - Yes
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H1
- Analog Inputs - Yes
- Application: Object Counting - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - No
- Housing Style - Enclosed Terminals
- Input Details - 4 Discrete, 2 0-20 mA, 1 Thermistor, 1 counter
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H12
- Analog Inputs - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - No
- Housing Style - Enclosed Terminals
- Input Details - 2 Discrete, 2 0-20 mA, 1 Thermistor, 2 SDI-12
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Soil Moisture Monitoring - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H12C
- Analog Inputs - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP20
- Environmental Rating (NEMA) - NEMA 1
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - External Terminals
- Input Details - 2 Discrete, 2 0-20 mA, 1 Thermistor, 2 SDI-12
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Soil Moisture Monitoring - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H12E
- Analog Inputs - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP65
- Environmental Rating (NEMA) - NEMA 4x
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - Integrated Battery
- Input Details - 2 Discrete, 2 0-20 mA, 1 Thermistor, 2 SDI-12
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 65
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - D-Cell Lithium
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Soil Moisture Monitoring - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H14
- Analog Inputs - Yes
- Application: Object Counting - Yes
- Application: Temperature Input - Yes
- Device Type - Data Radio
- Discrete Inputs - Yes
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - No
- Housing Style - Integrated Battery
- Input Details - Configurable discrete, configurable analog, thermistor, asynchronous counter, SDI-12
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 85
- Min Operating Temperature ( °C) - -40
- Modbus RTU - Yes
- Output Details - Switch Power
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - D-Cell Lithium
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Soil Moisture Monitoring - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H14-NB
- Analog Inputs - Yes
- Application: Object Counting - Yes
- Application: Temperature Input - Yes
- Device Type - Data Radio
- Discrete Inputs - Yes
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - No
- Housing Style - Integrated Battery
- Input Details - Configurable discrete, configurable analog, thermistor, asynchronous counter, SDI-12
- Input/output - Analog & Discrete
- LCD Display - Yes
- Modbus RTU - Yes
- Output Details - Switch Power
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - D-Cell Lithium
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Soil Moisture Monitoring - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H1C
- Analog Inputs - Yes
- Application: Object Counting - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP20
- Environmental Rating (NEMA) - NEMA 1
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - External Terminals
- Input Details - 4 Discrete, 2 0-20 mA, 1 Thermistor, 1 counter
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc or 3.6-5.5V dc low power option
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H1E
- Analog Inputs - Yes
- Application: Object Counting - Yes
- Application: Temperature Input - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP65
- Environmental Rating (NEMA) - NEMA 4x
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - Integrated Battery
- Input Details - 4 Discrete, 2 0-20 mA, 1 Thermistor, 1 counter
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 65
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 2 NMOS Discrete
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - D-Cell Lithium
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H2
- Analog Inputs - Yes
- Analog Outputs - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP67
- Environmental Rating (NEMA) - NEMA 6
- Feature: Hazardous Area - No
- Housing Style - Enclosed Terminals
- Input Details - 4 Discrete, 2 0-20 mA Analog
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 4 Sourcing Discrete, 2 0-20mA Analog
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
DX80DR2M-H2C
- Analog Inputs - Yes
- Analog Outputs - Yes
- Device Type - Multihop
- Discrete Inputs - Yes
- Discrete Outputs - Yes
- Environmental Rating (IP) - IP20
- Environmental Rating (NEMA) - NEMA 1
- Feature: Hazardous Area - Yes
- Hazardous/Intrinsically Safe Classification - Class I, Division 2/Zone 2; ATEX Zone 2
- Housing Style - External Terminals
- Input Details - 4 Discrete, 2 0-20 mA Analog
- Input/output - Analog & Discrete
- LCD Display - Yes
- Max Operating Temperature ( °C) - 80
- Min Operating Temperature ( °C) - -20
- Modbus RTU - Yes
- Output Details - 4 Sourcing Discrete, 2 0-20mA Analog
- Point-to-Multipoint Topology - Yes
- Point-to-Point Topology - Yes
- Power Supply - 10-30V dc
- Radio Frequency - 2.4 GHz
- Relative Humidity - 95%
- RS-485 - Yes
- Star Topology - Yes
- Tree Topology - Yes
- Wireless - Yes
1 - 12 of 48 Part Numbers
Documentation
Data Sheets
- Antenna Performance White Paper pdf 925 KB
- Banner Engineering MultiHop Modbus I/O Data Radio Data Sheets pdf 184 KB
- Banner Engineering MultiHop Modbus I/O Data Radio Document pdf 637 KB
- Conducting a Site Survey and Interpreting the Results PDF-67 pdf 276 KB
- Countries Approved for Sure Cross Products PDF-53 pdf 132 KB
- DX80 MultiHop Ethernet Data Radio Promo Flyer pdf 210 KB
- Host Controller Systems pdf 5.3 MB
- Kablosuz Olarak Vibrasyon ve S cakl k zleme pdf 264 KB
- Komunikacja bezprzewodowa PDF-50 pdf 2.2 MB
- Monitoraggio wireless delle vibrazioni e della temperatura PDF-64 pdf 268 KB
- MultiHop 2222 Board M HB2 pdf 495 KB
- MultiHop Data Radio M H pdf 662 KB
- MultiHop FlexPower Board with 2220 I O M HB1 PDF-55 pdf 477 KB
- MultiHop M GAGE Radio M HMT Puck pdf 1.9 MB
- MultiHop Radio with DC Latching M DCLATCH pdf 556 KB
- MultiHop Radio with Disc Ana I O M H5 pdf 637 KB
- MultiHop Radio with I O M H1 pdf 998 KB
- MultiHop Radio with RTD I O M H4 PDF-62 pdf 918 KB
- MultiHop Radio with SDI 12 I O M H12 pdf 969 KB
- MultiHop Radio with SDI 12 M H14 pdf 856 KB
- MultiHop Radio with Serial Interface M H6 pdf 1.3 MB
- MultiHop Radio with Thermocouple I O M H3 pdf 966 KB
- MultiHop Register Parameters pdf 455 KB
- MultiHop TechNote Enabling Deep Sleep Mode PDF-73 pdf 64 KB
- MultiHop TechNote Network Formation Tables PDF-59 pdf 55 KB
- MultiHop TechNote Serial Connections from Host to MultiHop Radio to Gateway pdf 272 KB
- MultiHop TechNote Setting the Baud Rate to 1200 or 2400 PDF-54 pdf 11 KB
- Power Solutions FlexPower and Battery Life Calculations PDF-65 pdf 916 KB
- Power Solutions Solar PDF-75 pdf 1.5 MB
- Schwingungs und Temperatur Funk berwachung pdf 269 KB
- SDI 12 and the Acclima TDT SDI 12 Soil Moisture Probe PDF-61 pdf 292 KB
- SDI 12 and the AquaCheck Sub Surface Soil Moisture Probe pdf 636 KB
- SDI 12 and the Decagon 5TE Soil Moisture Probe PDF-68 pdf 274 KB
- SDI 12 and the Decagon GS3 Soil Moisture Probe PDF-66 pdf 273 KB
- SDI 12 and the Decagon MPS 2 Soil Moisture Probe pdf 287 KB
- SDI 12 and the HydraScout HSTI Probe pdf 652 KB
- SDI 12 and the Sentek EnviroScan Probe pdf 596 KB
- Sensor Connections Guide pdf 93 KB
- Serial Data Radio Flyer pdf 184 KB
- Solution sans fil pour la surveillance de la temp rature et des vibrations pdf 269 KB
- Solutions Sans Fil d Entr es Sorties PDF-63 pdf 2.2 MB
- Solutions sans fil pour le Stationnement Intelligent pdf 2.5 MB
- Soluzioni I O wireless pdf 2.2 MB
- Sure Cross Antenna Basics pdf 1.1 MB
- Sure Cross Wireless Security pdf 125 KB
- SureCross MultiHop Radio with I O M H2 pdf 654 KB
- System Layouts Examples pdf 371 KB
- Tech Note Verifying Communication Between DXM MultiHop Master and Slave pdf 448 KB
- TechNote Connecting an M GAGE or R GAGE to the Banner Sensor GUI Using Data Radios pdf 264 KB
- TechNote Connecting Multiple VT2 Sensors to a MultiHop Radio PDF-74 pdf 232 KB
- TechNote DC Latching Operation pdf 146 KB
- TechNote Forced Routing for MultiHop Radios pdf 54 KB
- TechNote Triggering Binding Mode from a Modbus Host Controller pdf 179 KB
- TechNote Using Banner Wireless Systems in a Wi Fi Environment PDF-56 pdf 318 KB
- TechNote Verifying Communication Between a Modbus or SDI 12 Sensor and MultiHop pdf 829 KB
- Wireless Agriculture Solutions pdf 1.1 MB
- Wireless I O Flyer Chinese Traditional PDF-58 pdf 10.4 MB
- Wireless I O Solutions PDF-70 pdf 2.2 MB
- Wireless P14 and H14 Sell Sheet PDF-57 pdf 644 KB
- Wireless Solutions for Environmental and Process Monitoring pdf 2.2 MB
- Wireless Solutions for Smart Parking PDF-71 pdf 2.5 MB
- Wireless Vibration and Temperature Sensor pdf 789 KB
- Wireless Vibration and Temperature Sensor Brazil PDF-72 pdf 1.5 MB
- Wireless Vibration and Temperature Sensor Korea pdf 1.7 MB
- Wireless Vibration and Temperature Sensor Mexico pdf 1.7 MB
Product Manuals
- Banner Engineering MultiHop Modbus I/O Data Radio Product Manuals pdf 324 KB
- Installing Your Sure Cross Radios chapter in manual pdf 859 KB
- MultiHop Configuration Tool Instruction Manual pdf 1.6 MB
- MultiHop TechNote Manually Assigning a Binding Code pdf 324 KB
- Sure Cross MultiHop Radio Instruction Manual pdf 2.0 MB