Yodify Product Library
Instantly add the 8222 Conductivity Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
8222 Conductivity Meter
Brand: Burkert Fluid Control SystemsThe Burkert compact meter Type 8222 is designed for measuring the conductivity of fluids. The conductivity meter consists of a sensor, plugged-in and pined to the transmitter (with removable display).
The sensor comprises a cell with two electrodes and a Pt1000 temperature probe. The sensor itself is available with three different cell constants C, these with C = 0.01 or 0.1 are fitted with stainless steel electrodes and those with C = 1.0 are fitted with graphite electrodes.
The conductivity meter can operate independent of the display but it will be required for programming the device and also for visualizing continuously the measured and processed data.
Features- Perfect for clean water and slightly concentrated liquids
- Integral device for direct connection to PLC
- Simulation of process values for diagnostics
- Three cell constants to cover a wide application range e.g. reverse osmosis
1 - 12 of 24 Part Numbers
559 610
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 1.0
- Nut Material - PVC
- Certification - No UL Certification
559 611
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 1.0
- Nut Material - PVC
- Certification - No UL Certification
559 612
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 1.0
- Nut Material - PVDF
- Certification - No UL Certification
559 613
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 1.0
- Nut Material - PVDF
- Certification - No UL Certification
559 614
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 0.1
- Nut Material - PVC
- Certification - No UL Certification
559 615
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 0.1
- Nut Material - PVC
- Certification - No UL Certification
559 616
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 0.1
- Nut Material - PVDF
- Certification - No UL Certification
559 617
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 0.1
- Nut Material - PVDF
- Certification - No UL Certification
559 618
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 0.01
- Nut Material - PVC
- Certification - No UL Certification
559 619
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 0.01
- Nut Material - PVC
- Certification - No UL Certification
559 620
- Supply Voltage - 14-36 Vdc
- Sensor Version - C = 0.01
- Nut Material - PVDF
- Certification - No UL Certification
559 621
- Supply Voltage - 12-36 Vdc
- Sensor Version - C = 0.01
- Nut Material - PVDF
- Certification - No UL Certification
1 - 12 of 24 Part Numbers
Specifications
Ambient Temperature Range
- Operating & Storage: -10° to 60° C (14° to 140° F)
Approvals & Certifications
- Calibration Certificates
- CE
- EU Directives
- FDA
- PED 2014/68/EU
- UL (C,US): UL 61010-1 + CAN/CSA C22.2 No.61010-1
BSP Connection
- G 1-1/2” Male
Circuit Protection
- Short Circuit: Protected for Transistor Outputs
Consumption
- Current [3 Outputs Meter (2-Wire)]: ≤ 25 mA at 14 Vdc without Transistors Load, with Current Loop
- Current [4 Outputs Meter (3-Wire)]: ≤ 5 mA at 12 Vdc without Transistors Load, without Current Loop
- Current: ≤ 1 A with the 2 Transistors Loads
Cover Material
- Polycarbonate (PC)
Current
- 4-20 mA
Diameter
- Pipe: 0.9 to 4.3” (25 to 110 mm)
Electrical Connectors
- 3 Outputs Meter (2-Wire): 1 x 5-Pin M12 Male Fixed Connector
- 4 Outputs Meter (3-Wire): 1 x 5-Pin M12 Male + 1 x 5-Pin M12 Female Fixed Connectors
- Shielded Cable
Electrical Protection
- Voltage Peak: Protected
Enclosure, Body Material
- 316L Stainless Steel, 1.4404
- PPS
Environmental Protection
- IP65
- IP67
Humidity
- ≤ 85 % Relative Humidity, Non-Condensing
Loop Impedance
- 1,100 ohms at 36 Vdc, Max.
- 3 Outputs Meter (2-Wire): 180 ohms at 14 Vdc, Max.
- 4 Outputs Meter (3-Wire): 100 ohms at 12 Vdc, Max.
- 610 ohms at 24 Vdc, Max.
Materials of Construction
- Display: Polycarbonate (PC)
- Fixed Connector Mounting Plate: 316L Stainless Steel, 1.4404
- Fixed Connector: Brass Nickel-Plated
- Navigation Key: PBT
Measuring Error
- Conductivity Measurement Deviation: ± 3 % of Measured Value
- Temperature Measurement Deviation: ± 1° C (1.8° F)
Measuring Range
- Conductivity Measurement: 0.05 to 10,000 µS/cm
Media
- Water
Nut & Bolt Material
- Nut: PVC
- Nut: PVDF
Output
- 4-20 mA
- Transistor (NPN): 0.2-36 Vdc
Output Format
- Open Collector (700 mA, 0.5 A) - Max.
Power Supply
- 3 Outputs Meter (2-Wire): 14-36 Vdc, Filtered & Regulated
- 4 Outputs Meter (3-Wire): 12-36, Filtered & Regulated
Pressure Range
- psi: 0 to 232 (kPa: 0 to 1,600, bar: 0 to 16) - Max.
Process Temperature
- With G 1-1/2” PVC Nut Connection: 0° to 50° C (32° to 122° F)
- With G 1-1/2” PVDF Nut Connection: -20° to 100° C (-4° to 212° F) Restricted by the used Adaptor
Resolution
- Conductivity Measurement: 1 NS/cm
- Temperature Measurement (Internal Resolution): 0.1° C (0.18° F)
Response Time
- 10 to 90 %: 150 milliseconds
Reverse Polarity Protection
- Protected Against Reverse Polarity
RTD Type
- Pt1000
Screw Material
- Stainless Steel
Seat / Seal Material
- Seal: EPDM
- Seal: Silicone
Sensor, Probe Material
- Conductivity Sensor: 316Ti Stainless Steel 1.4571
- Conductivity Sensor: PVDF
Switch Type
- Transistor (PNP or NPN)
Temperature Range
- Minimal Temperature Range: 10° to 20° C (50° to 68° F) Corresponding to 4-20 mA
- Temperature Measurement: -20° to 100° C (-4° to 212° F)
Wetted Materials
- Electrode: 316Ti Stainless Steel 1.4571 for Cell Constant C = 0.01 or C = 0.1
- Electrode: Graphite for Cell Constant C = 1.0