Yodify Product Library
Instantly add the Cable Glands Ex e & Ex d & Ex nR & Ex ta Series PX2K and 50,000+ more product series to yourĀ store or catalogĀ Ā
Book Your Demo and See How
or create your store
Cable Glands Ex e & Ex d & Ex nR & Ex ta Series PX2K
Brand: R. STAHL AGPX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armored cables, i.e. for SWA, braid- and tape-type steel and aluminium armoring. They are equipped with a compound barrier.
They feature a multi-functional holder for the armoring and various seals. They are also EMC-tested.
Features- Ex d and Ex e cable entry for all armored cables: SWA, braid- and tape-type steel or aluminium armoring
- Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
- Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
1 - 12 of 20 Part Numbers
109426
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-20S16-PX2K
- Title Product Variant Technical Data - CMP-20s/16PX2K gland NB M20
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 6.10 - 13.10 mm
- Clamping range max. - 13.10 mm
- Clamping range min. - 6.10 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s/16
- Grooved cone - 0.30 … 1.00 mm
- Inner conduit diameter max. - 11.70 mm
- Inner sheath - 11.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 11
- Outer sheath - 6.10 … 13.10 mm
- Protrusion length - 62.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 0.80 … 1.25 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.240 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
109427
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-20S-PX2K
- Title Product Variant Technical Data - CMP-20sPX2K gland NB M20
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 9.50 - 15.90 mm
- Clamping range max. - 15.90 mm
- Clamping range min. - 9.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20s
- Grooved cone - 0.30 … 1.00 mm
- Inner conduit diameter max. - 11.70 mm
- Inner sheath - 11.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 11
- Outer sheath - 9.50 … 15.90 mm
- Protrusion length - 62.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 0.80 … 1.25 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.230 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
109428
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Description - Ex d & Ex e Compound barrier cable gland for all types of armoured cables (SWA, braided, tape) (nickel plated brass)
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-20-PX2K
- Product Variant - Cable glands made of metal
- Title Product Variant Technical Data - CMP-20PX2K gland NB M20
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 12.50 - 20.90 mm
- Clamping range max. - 20.90 mm
- Clamping range min. - 12.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 20
- Grooved cone - 0.40 … 1.00 mm
- Inner conduit diameter max. - 12.90 mm
- Inner sheath - 12.60 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 11
- Outer sheath - 12.50 … 20.90 mm
- Protrusion length - 63.00 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 0.80 … 1.25 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M20
- Thread standard - metric
- Weight - 0.240 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
109430
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-32-PX2K
- Title Product Variant Technical Data - CMP-32PX2K gland NB M32
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 23.70 - 33.90 mm
- Clamping range max. - 33.90 mm
- Clamping range min. - 23.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 32
- Grooved cone - 0.40 … 1.20 mm
- Inner conduit diameter max. - 23.90 mm
- Inner sheath - 23.60 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 38
- Outer sheath - 23.70 … 33.90 mm
- Protrusion length - 75.00 mm
- PVC-shroud - PVC11
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 1.60 … 2.00 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M32
- Thread standard - metric
- Weight - 0.570 kg
- Width across corners - 50.60 mm
- Width across flats - 46.00 mm
109431
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-40-PX2K
- Title Product Variant Technical Data - CMP-40PX2K gland NB M40
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 27.90 - 40.40 mm
- Clamping range max. - 40.40 mm
- Clamping range min. - 27.90 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 40
- Grooved cone - 0.40 … 1.60 mm
- Inner conduit diameter max. - 30.30 mm
- Inner sheath - 30.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 59
- Outer sheath - 27.90 … 40.40 mm
- Protrusion length - 75.00 mm
- PVC-shroud - PVC15
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 1.60 … 2.00 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M40
- Thread standard - metric
- Weight - 0.800 kg
- Width across corners - 60.50 mm
- Width across flats - 55.00 mm
109432
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-50S-PX2K
- Title Product Variant Technical Data - CMP-50sPX2K gland NB M50
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 35.20 - 46.70 mm
- Clamping range max. - 46.70 mm
- Clamping range min. - 35.20 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50s
- Grooved cone - 0.40 … 1.60 mm
- Inner conduit diameter max. - 36.90 mm
- Inner sheath - 36.60 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 89
- Outer sheath - 35.20 … 46.70 mm
- Protrusion length - 77.00 mm
- PVC-shroud - PVC18
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.00 … 2.50 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M50
- Thread standard - metric
- Weight - 0.900 kg
- Width across corners - 66.00 mm
- Width across flats - 60.00 mm
109433
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-50-PX2K
- Title Product Variant Technical Data - CMP-50PX2K gland NB M50
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 40.40 - 53.00 mm
- Clamping range max. - 53.00 mm
- Clamping range min. - 40.40 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 50
- Grooved cone - 0.60 … 1.60 mm
- Inner conduit diameter max. - 41.30 mm
- Inner sheath - 41.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 89
- Outer sheath - 40.40 … 53.00 mm
- Protrusion length - 77.00 mm
- PVC-shroud - PVC21
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.00 … 2.50 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M50
- Thread standard - metric
- Weight - 1.190 kg
- Width across corners - 77.00 mm
- Width across flats - 70.00 mm
109434
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-63S-PX2K
- Title Product Variant Technical Data - CMP-63sPX2K gland NB M63
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 45.60 - 59.40 mm
- Clamping range max. - 59.40 mm
- Clamping range min. - 45.60 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63s
- Grooved cone - 0.60 … 1.60 mm
- Inner conduit diameter max. - 48.40 mm
- Inner sheath - 47.90 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 115
- Outer sheath - 45.60 … 59.40 mm
- Protrusion length - 79.70 mm
- PVC-shroud - PVC23
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.00 … 2.50 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M63
- Thread standard - metric
- Weight - 1.390 kg
- Width across corners - 82.50 mm
- Width across flats - 75.00 mm
109435
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-63-PX2K
- Title Product Variant Technical Data - CMP-63PX2K gland NB M63
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 54.60 - 65.90 mm
- Clamping range max. - 65.90 mm
- Clamping range min. - 54.60 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 63
- Grooved cone - 0.60 … 1.60 mm
- Inner conduit diameter max. - 54.00 mm
- Inner sheath - 53.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 115
- Outer sheath - 54.60 … 65.90 mm
- Protrusion length - 80.30 mm
- PVC-shroud - PVC25
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.00 … 2.50 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M63
- Thread standard - metric
- Weight - 1.410 kg
- Width across corners - 88.00 mm
- Width across flats - 80.00 mm
109436
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-75S-PX2K
- Title Product Variant Technical Data - CMP-75sPX2K gland NB M75
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 59.00 - 72.00 mm
- Clamping range max. - 72.00 mm
- Clamping range min. - 59.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 75s
- Grooved cone - 0.60 … 1.60 mm
- Inner conduit diameter max. - 60.20 mm
- Inner sheath - 59.90 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 140
- Outer sheath - 59.00 … 72.00 mm
- Protrusion length - 86.80 mm
- PVC-shroud - PVC28
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.00 … 2.50 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M75
- Thread standard - metric
- Weight - 2.090 kg
- Width across corners - 99.00 mm
- Width across flats - 90.00 mm
109437
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-75-PX2K
- Title Product Variant Technical Data - CMP-75PX2K gland NB M75
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 66.70 - 78.40 mm
- Clamping range max. - 78.40 mm
- Clamping range min. - 66.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 75
- Grooved cone - 0.60 … 1.60 mm
- Inner conduit diameter max. - 64.20 mm
- Inner sheath - 64.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 140
- Outer sheath - 66.70 … 78.40 mm
- Protrusion length - 88.30 mm
- PVC-shroud - PVC30
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 2.50 … 3.00 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M75
- Thread standard - metric
- Weight - 2.540 kg
- Width across corners - 110.00 mm
- Width across flats - 100.00 mm
243532
Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring
Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection
Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
Ambient Conditions
- Ambient temperature - -60 °C ... +85 °C
- Ambient temperature max. - +85 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e & Ex d & Ex nR & Ex ta
Explosion Protection
- Ambient temperature °C - -60 - 85 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 13 ATEX 1072 X
- ATEX firedamp certificate - SIRA 13 ATEX 1072 X
- ATEX gas certificate - SIRA 13 ATEX 1072 X
- ATEX restricted breathing certificate - SIRA 13 ATEX 4078 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 1 D Ex ta IIIC Da
- Dust explosion protection EAC - Ex ta IIIC Da X
- Dust explosion protection IECEx - Ex ta IIIC Da
- Firedamp protection ATEX - I M2 Ex d I Mb
- Firedamp protection ATEX 2 - I M2 Ex e I Mb
- Firedamp protection IECEx - Ex d I Mb
- Firedamp protection IECEx 2 - Ex e I Mb
- Gas explosion protection ATEX - II 2 G Ex d IIC Gb
- Gas explosion protection ATEX 2 - II 2 G Ex e Gb
- Gas explosion protection EAC - 1 Ex d e IIC Gb X 2 Ex nR IIC Gc X
- Gas explosion protection IECEx - Ex d IIC Gb
- Gas explosion protection IECEx 2 - Ex e Gb
- IECEX dust certificate - IECEx SIR 13.0027 X
- IECEx firedamp certificate - IECEx SIM 14.0008 X
- IECEX gas certificate - IECEx SIR 13.0027 X
- IECEx restricted breathing certificate - IECEx SIR 13.0027 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
- Restricted breathing ATEX - II 3 G Ex nR IIC Gc
- Restricted breathing IECEx - Ex nR IIC Gc
General
- Functional Description - PX2K series metal Ex d and Ex e barrier cable entries are suitable for all types of armoured cables, i.e. for SWA, braid- and tape-type steel and aluminium armouring. They are equipped with a compound barrier. They feature a multi-functional holder for the armouring and various seals. They are also EMC-tested.
- Highlights - Ex d and Ex e cable entry for all armoured cables: SWA, braid- and tape-type steel or aluminium armouring Sealing: Explosion-protected seal with compound, controlled outer load retention seal and flood seal with integral protection Worldwide certification in accordance with IECEx, ATEX, UL and cCSAus, EMC-tested
- Product Description - Cable gland With compound
- Product Type - CMP-25S-PX2K
- Title Product Variant Technical Data - CMP-25sPX2K gland NB M25
- WebCode - PX2KA
Mechanical Data
- Armouring type - All armouring
- Armouring type 2 - without lead sheath
- Armouring type 3 - with barrier seal
- Clamping range - 14.00 - 22.00 mm
- Clamping range max. - 22.00 mm
- Clamping range min. - 14.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - IP67 and IP68 mounting in accordance with the specifications of the manufacturer, CMP
- Gland size - 25s
- Grooved cone - 0.40 … 1.20 mm
- Inner conduit diameter max. - 17.90 mm
- Inner sheath - 17.50 mm
- Lot size - 1
- Material - Nickel-plated brass
- Material sealing ring - Viton
- Max. number of cores - 21
- Outer sheath - 14.00 … 22.00 mm
- Protrusion length - 69.50 mm
- PVC-shroud - PVC09
- Sealing material - SOLO LSF
- Silicone-free - No
- Stepped cone - 1.25 … 1.60 mm
- Thread length - 15.000 mm
- Thread pitch - 1,5
- Thread size - M25
- Thread standard - metric
- Weight - 0.370 kg
- Width across corners - 41.30 mm
- Width across flats - 37.50 mm
1 - 12 of 20 Part Numbers