Yodify Product Library
Instantly add the Ammeter for Ex i Circuits Series 8402/6 and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Ammeter for Ex i Circuits Series 8402/6
Brand: R. STAHL AGR. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
Features- Ammeters in various versions, for Ex i circuits and Ex e enclosures
- Quicker comparison of measured values using externally adjustable red pointers on the device
- Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
1 - 4 of 4 Part Numbers
262111
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 3.00 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 0 mA
- Rated operational current AC - 0.020 - 0.020 A
- Short-circuit current max. - 160 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 18 ATEX 018 X
- Gas explosion protection ATEX - II 2 G Ex ib IIC T4...T6 Gb
- Gas explosion protection IECEx - Ex ib IIC T4...T6 Gb
- IECEX gas certificate - IECEx SIQ 18.0003X
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/6-020
- Title Product Variant Technical Data - 8402/6-020 Ammeter Ex i
- WebCode - 8402B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 4.00 mm²
- Connection cross-section solid max. - 6.00 mm²
- Connection cross-section solid min. - 0.34 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polyamide
- Height - 71.200 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.210 kg
- Width - 72.000 mm
Mounting / Installation
- Tightening torque - 1.2 ... 1.5 Nm
Safety Data
- Internal capacitance C i - 0
- Internal inductance L i - 90 µH
262112
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - without
Electrical Data
- Internal resistance R i - 3.00 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 4 mA
- Rated operational current AC - 0.020 - 0.020 A
- Short-circuit current max. - 160 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 18 ATEX 018 X
- Gas explosion protection ATEX - II 2 G Ex ib IIC T4...T6 Gb
- Gas explosion protection IECEx - Ex ib IIC T4...T6 Gb
- IECEX gas certificate - IECEx SIQ 18.0003X
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/6-420
- Title Product Variant Technical Data - 8402/6-420 Ammeter Ex i
- WebCode - 8402B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 4.00 mm²
- Connection cross-section solid max. - 6.00 mm²
- Connection cross-section solid min. - 0.34 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polyamide
- Height - 71.200 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.210 kg
- Width - 72.000 mm
Mounting / Installation
- Tightening torque - 1.2 ... 1.5 Nm
Safety Data
- Internal capacitance C i - 0
- Internal inductance L i - 90 µH
267109
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 100 / 200%
Electrical Data
- Internal resistance R i - 3.00 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 0 mA
- Rated operational current AC - 0.020 - 0.020 A
- Short-circuit current max. - 160 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 18 ATEX 018 X
- Gas explosion protection ATEX - II 2 G Ex ib IIC T4...T6 Gb
- Gas explosion protection IECEx - Ex ib IIC T4...T6 Gb
- IECEX gas certificate - IECEx SIQ 18.0003X
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/6-020
- Title Product Variant Technical Data - 8402/6-020 Amm. Ex i w.scale 0-100%
- WebCode - 8402B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 4.00 mm²
- Connection cross-section solid max. - 6.00 mm²
- Connection cross-section solid min. - 0.34 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polyamide
- Height - 71.200 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.210 kg
- Width - 72.000 mm
Mounting / Installation
- Tightening torque - 1.2 ... 1.5 Nm
Safety Data
- Internal capacitance C i - 0
- Internal inductance L i - 90 µH
267131
Ammeters in various versions, for Ex i circuits and Ex e enclosures
Quicker comparison of measured values using externally adjustable red pointers on the device
Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
Ambient Conditions
- Ambient temperature - -40 °C ... +70 °C
- Ambient temperature max. - +70 °C
- Ambient temperature min. - -40 °C
Components
- Scale - 0 - 100 / 200%
Electrical Data
- Internal resistance R i - 3.00 Ω
- Measuring range max. - 20 mA
- Measuring range min. - 4 mA
- Rated operational current AC - 0.020 - 0.020 A
- Short-circuit current max. - 160 mA
Explosion Protection
- Application range (zones) - 1, 2
- ATEX gas certificate - SIQ 18 ATEX 018 X
- Gas explosion protection ATEX - II 2 G Ex ib IIC T4...T6 Gb
- Gas explosion protection IECEx - Ex ib IIC T4...T6 Gb
- IECEX gas certificate - IECEx SIQ 18.0003X
General
- Functional Description - R. STAHL Series 8402 ammeters are installed in Ex e type of protection enclosures. They provide measured values for Ex i circuits which can be quickly compared with the desired values via a red pointer affixed on the outside. The devices work with a moving iron movement with accuracy class 2.5.
- Highlights - Ammeters in various versions, for Ex i circuits and Ex e enclosures Quicker comparison of measured values using externally adjustable red pointers on the device Selection of different current measuring ranges of between 0 and 20 mA or 4 to 20 mA
- Product Description - Moving coil ammeter Direct measuring For Ex i electrical circuit
- Product Type - 8402/6-420
- Title Product Variant Technical Data - 8402/6-420 Amm. Ex i w.scale 0-100%
- WebCode - 8402B
Mechanical Data
- Accuracy class - 2.5
- Connection cross-section finely stranded max. - 4.00 mm²
- Connection cross-section solid max. - 6.00 mm²
- Connection cross-section solid min. - 0.34 mm²
- Degree of protection (IP) - IP54
- Depth - 72.000 mm
- Enclosure material - Polyamide
- Height - 71.200 mm
- Silicone-free - Yes
- Terminal degree of protection (IP) - IP20
- Weight - 0.210 kg
- Width - 72.000 mm
Mounting / Installation
- Tightening torque - 1.2 ... 1.5 Nm
Safety Data
- Internal capacitance C i - 0
- Internal inductance L i - 90 µH
1 - 4 of 4 Part Numbers