Yodify Product Library
Instantly add the TVM™ Voltage Monitor and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

The Honeywell A3 ALPHA Meter brings advanced metering capabilities to commercial and industrial applications. 

The Sensus FlexNet Communication Network SmartPoint module is integrated into the A3 ALPHA providing secure and robust two-way communications capabilities.

 No special equipment is necessary because the SmartPoint module automatically establishes the communication path to the Sensus Base Station.

Utilities today rely on big data to help make intelligent decisions about their energy needs. 

A3 ALPHA meters can collect six channels of load profile information (for example, kWh or kVARh) and up to 15 configurable snapshot registers delivering even more information. 

The SmartPoint module retrieves the data directly from the A3 ALPHA meter tables and transmits it over the secure FlexNet communications network.
Features
  • kWh, kVARh, and kVAh bidirectional energy
  • Demand
  • Time-of-use (TOU)
  • Power factor
  • Instrumentation profiling (including quantities such as phase voltage)
  • 6 channels load profile
  • 15 snapshot registers
  •  Loss compensation
  • 2-relay or 4-relay outputs and are fully programmable using Honeywell’s meter support software
  • History and event logs
  • Voltage sag log
  • Over-the-air (OTA) metrology firmware and configuration updates

Specifications

Maximum Voltage/Current

  • Voltage: Continuous 528 Vac
  • Current: Continuous at Class amperes, temporary (1 second) at 200 % of meter Max. Current

Voltage Range

  • Operating 96 V to 528 V
  • Nameplate Nominal 120 V to 480 V

Surge Voltage Withstand

  • ANSI C12.1 insulation 2.5 kV, 60 Hz for 1 minute
  • IEC 61000-4-4 4 kV, 2.5 kHz repetitive burst for 1 minute
  • ANSI C62.41 6 kV at 1.2/50 µs, 10 strikes

Current Range

  • 0 to Class amperes

Frequency Range

  • Nominal 50 Hz or 60 Hz ± 5 %

Operating Environment

  • Humidity: 0 % to 100 % Non-Condensing
  • Temperature: -40° C to +85° C (-40° F to 185° F)

Power Supply Burden

  • Less than 4 W

Per Phase Current/Voltage Burden

  • Voltage: .008 W at 120 V, 0.03 W at 240 V, 0.04 W at 480 V
  • Current: 0.1 milliohms typical at 25° C

Primary/Secondary Time Base

  • Initial performance is expected to be equal to or better than ± 55 seconds per month at room Temperature.
  • Secondary: Meets the ANSI limit of 0.02 % using the 32.768 kHz crystal.
  • Primary: Power line frequency (50 Hz or 60 Hz) with selectable crystal oscillator.

Outage Carryover

  • Battery included on all but A3D meters for additional carryover
  • 6 hours at 25° C. Super capacitor rated at 0.1 Farads, 5.5 V

Communication Rates

  • Remote Port: 1,200 bps to 19,200 bps
  • Optical Port: 300 bps to 28,800 bps

Dimensions

  • Depth: 13.9 cm (5.5 inches)
  • Diameter: 17.70 cm (6.95 inches)

Accuracy

  • Typical accuracy within ± 0.2 %
  • Meets ANSI C12.20 for accuracy

Tamper Detection Options

  • If the meter is inverted, energy can be added to the total accumulation.
  • The meter can be configured to Alarm on reverse energy. FlexNet module-based vibration Sensor.

Complies with Industry Standards

  • ANSI C12.1, ANSI C12.10, ANSI C12.18, ANSI C12.19, ANSI C12.20, FCC Part 15, UL 2735 Listed

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more