Yodify Product Library
Instantly add the 6500/6505 Reaction Torque Meter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

6500/6505 Reaction Torque Meter

Brand: Sensy - Sensors & Synergy S.A.

Non-rotating torque meters with hexagonal head.
Features
  • Broad range of capacities: from 2 to 1,000 Nm
  • Easy to install
  • Compact design
  • Protection IP 54
  • Materials:
    • Stainless steel (6500)
    • Nickel plated steel (6505)
  • Available options (non exhaustive list):
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
    • Double strain-gauge bridge
    • Cable output with connector

1 - 2 of 2 Part Numbers
6500
6500
  • Body Material - Stainless Steel
6505
6505
  • Body Material - Nickel-Plated Steel
1 - 2 of 2 Part Numbers

Specifications

Applications

  • Calibration Standards
  • Torque Control

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 1.6 to 20 feet (0.5 to 6.0 metres)

Capacity

  • 2 to 1,000 Nm

Communication

  • RS-232C
  • RS-485
  • USB

Enclosure, Body Material

  • Nickel-Plated Steel (6505)
  • Stainless Steel (6500)

Environmental Protection

  • IP54

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms at 50 V

Linearity

  • < ± 0.25 % of Full Scale - Error

Load

  • > 300 % of Full Scale - Breaking
  • 40 % of Full Scale - Dynamic Loading

Load Limit

  • 120 % of Full Scale

Operating Temperature

  • 180° C (356° F) - High Service Temperature

Repeatability

  • < ± 0.1 % of Full Scale - Error

Resistance

  • 352 ± 2 ohms - Input/Output

Sensitivity

  • < ± 0.3 % - Tolerance
  • 1.5 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 10 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.035 % of Full Scale/10° C (18° F) - Zero Signal
  • < ± 0.05 % of Full Scale/10° C (18° F) - Temperature Coefficient of the Sensitivity

Temperature Range

  • -10° to 45° C (14° to 113° F) - Nominal

Zero Balance

  • ± 0.02 mV/V

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more