Brand: Setra Systems, IncSetra’s Model 522 general-purpose pressure transducer is designed for OEM industrial applications that require exceptional stability and high accuracy.
The Model 522’s CVD strain gauge design is resistant to aging and virtually insensitive to thermal transients and pressure cycling.
The stability of this technology assures the user of high reliability with less than 0.2% drift per year.
Features- General purpose
- Off-highway vehicles
- Industrial OEM equipment
- Hydraulic systems
- Pumps and compressors
- Industrial engines
- Process applications
Specifications
Brand
Accuracy
- ± 0.25 % of Full Scale RSS
Applications
- General-purpose
- Hydraulic Systems
- Industrial Engines
- Industrial OEM Equipment
- Off-Highway Vehicles
- Process Applications
- Pumps & Compressors
Approvals & Certifications
- ATEX Instrinsic Safe
- CE
- ETL for Class I, Div. 1, Groups C, D, Hazardous Areas
Burst Pressure
- > 20 x Full Scale ≤ psi: 1,000 (kPa: 6,895, bar: 60)
- > 35 x Full Scale ≤ psi: 100 (kPa: 689.5, bar: 6)
- > 5 x Full Scale ≤ psi: 6,000 (kPa: 41,370, bar: 400)
Compensated Temperature
- -20° to 80° C (-5° to 180° F)
Consumption
- Approximately 6 mA at 7.5 Vdc Output: Current Consumption
Electrical Connectors
- 2-Wire
- 3-Wire
- 4-Pin Mini DIN Connector w/o Mate
- 4-Wire
- Cable Gland
Enclosure, Body Material
- 316 Stainless Steel
- 630 Stainless Steel
Environmental Protection
- IP65
- IP66
- IP67
- NEMA 4
Excitation Voltage
- 1.5 Vdc Above Span to 35 Vdc
- 10 Vdc
- 15 Vdc, Max.
Loop Resistance
- (Vs-7) x 50 ohms
Media
- Corrosive
- Liquids & Gases
NPT Connection
- 1/2”-14 Male NPT
- 1/4”-18 Female NPT
- 1/4”-18 Male NPT
- 1/4” NPT Male w/ Snubber
- 1/8”-27 Male NPT
Operating Temperature
- -40° to 125° C (-40° to 260° F)
Output
- 0.1 to 5.1 Vdc
- 0.2 to 10.2 Vdc
- 0.5 - 5.5 Vdc
- 0-10 Vdc
- 0-5 Vdc
- 10 mV/V
- 100 mV
- 1-11 Vdc
- 1-5 Vdc
- 1-6 Vdc
- 4-20 mA
Pressure Range
- bar: 0 to 600
- kPa: 0 to 60,000
- psi: -14.5 to 8,702
Pressure Type
- Absolute
- Compound Pressure
- Gauge
Proof Pressure
- 1.5 times Full Scale or psi: 5,802 (kPa: 40,000, bar: 400), ≥ 5,000 psi
- 2 x Full Scale
Resistance
- Bridge: 2,600 to 6,000 ohms
Response Time
- 0.5 millisecond
SAE Connection
- SAE4 J1926-2
- SAE6 J1926-2
Sensor, Probe Material
- Silicon
Sensor, Probe Type
- Pressure Sensor
Shock
- 20 G, 11 milliseconds Per MIL-STD-81-E Method 516.4 Procedure 1
Span & Zero Effect
- 1.0 % of Full Scale/100° C (0.5 % of Full Scale/100° F)
- 1.5 % of Full Scale/100° C (0.83 % of Full Scale/100° F)
Stability
- 0.2 % of Full Scale Per Year - Long Term
Storage Temperature
- -40° to 125° C (-40° to 260° F)
Supply Voltage
- 24 Vdc - Loop
- 7-35 Vdc - Loop
UNF/UNC Connection
- 7/16”-20 UNF Male
- 9/16”-18 UNF Male
Vibration
- 70 G Peak-to-Peak Sinusoidal, 5 to 2,000 Hz (Random)
Wetted Materials
- 630 Stainless Steel