Yodify Product Library
Instantly add the 458 Direct CO₂ with CO Sensor Protection and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

458 Direct CO₂ with CO Sensor Protection

Brand: Kane International Limited

Features
  • Dual pump system for CO sensor ‘over-range’ protection
  • Structured commissioning test
  • Fast print
  • Screen protection
  • 6 line display
  • Factory fitted upgrades available
  • Structured commission test
  • Rotary switch for ease of use
  • Data hold
  • Logs and prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by and Tightness
    • Temperature
    • CO build up
    • Commission test

Specifications

Ambient Operating Range

  • 10 to 90% Relative Humidity, Non-Condensing
  • 0°C to ± 45°C

Battery Type / Life

  • > 8 Hours Using Alkaline AA Cells
  • 4 AA Cells

Charger (Optional)

  • 100 - 240 V Charger, for NiMH Batteries Only
  • 12 V in Vehicle Charger, for NiMH Batteries Only

Flue Gas Measurement Accuracy

  • Carbon Dioxide: ± 0.3% Volume
  • Carbon Monoxide (For 0 - 20 ppm Range): ± 3 ppm
  • Carbon Monoxide (For 21 - 2,000 ppm Range): ± 5% of Reading
  • Carbon Monoxide (For Above 2000 ppm Purge Pump Operates Range): Unspecified
  • CO / CO₂ Ratio: ± 5% of Reading
  • Efficiency (Net or Gross), Efficiency High (C): ± 1.0% of Reading
  • Excess Air: ± 0.2% of Reading
  • Oxygen: ± 0.3%

Flue Gas Measurement Range

  • Carbon Dioxide: 0 - 20%
  • Carbon Monoxide: 0 - 20 ppm
  • Carbon Monoxide: 21 - 2,000 ppm
  • Carbon Monoxide: Above 2000 ppm Purge Pump Operates
  • CO / CO₂ Ratio: 0 - 0.999
  • Efficiency (Net or Gross): 0 - 99.9%
  • Efficiency High (C): 0 - 119.9%
  • Excess Air: 0 - 250%
  • Oxygen: 0 -21%

Flue Gas Measurement Resolution

  • Carbon Monoxide: 1 ppm
  • CO / CO₂ Ratio: 0.0001%
  • Oxygen, Carbon Dioxide, Efficiency (Net or Gross), Efficiency High (C), Excess Air: 0.1%

Pre-Programmed Fuels

  • Natural Gas Propane, Butane, LPG, Light Oils (28/35 Sec), Wood Pellets, Town Gas, Coke Gas, Bio Oil, Bio Gas

Pressure (Differential) Accuracy

  • Nominal Range ± 80 Mbar: ± 0.005 Mbar

Pressure (Differential) Range

  • Nominal Range ± 80 Mbar: ± 0.2 Mbar

Pressure (Differential) Resolution

  • Nominal Range ± 80 Mbar: Max

Sensor, Probe

  • 300 mm Long Including Handle
  • 6 mm Diameter x 240 mm Long Stainless Steel Shaft with 2 m Long Neoprene Hose
  • Typical K Thermocouple

Storage Capacity

  • 20 Commissioning Tests
  • 20 Pressure & Temperature Tests
  • 20 Room CO Tests
  • 20 Temperature Tests
  • 20 Tightness Tests
  • 60 Combustion Tests

Temperature Measurement Accuracy

  • Flue Temperature, Inlet Temperature (External Sensor): ± 2.0°C ± 0.3% of Reading
  • Inlet Temperature (Internal Sensor): ± 1.0°C ± 0.3% of Reading

Temperature Measurement Range

  • Flue Temperature, Inlet Temperature (External Sensor): 0°C - 600°C
  • Inlet Temperature (Internal Sensor): 0°C to 50°C

Temperature Measurement Resolution

  • Flue Temperature, Inlet Temperature (Internal & External Sensor): 0.1°C

User Programmed Fuels

  • 5 User Defined Fuels
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team