Yodify Product Library
Instantly add the JEMStar II High Accuracy Revenue Meter and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

JEMStar II High Accuracy Revenue Meter

Brand: RIS - Scientific Columbus

The AMETEK Power Instruments' JEMStar II High Accuracy Revenue Meter is your cash register.

Fractions of a percent accuracy can mean the difference of hundreds of thousands of dollars.

Our precision design provides high accuracy with long term stability, making it easy to guarantee 0.05% accuracy for 10 years.

When compared to other meters, the JEMStar II can provide more than $13,000 per year in unaccounted revenue.

With a variety of ways you can customize the JEMStar II, the meter can be utilized for simple revenue and billing applications as well as more complex power quality monitoring applications.

We can equip the JEMStar II with up to seven communication ports including an internal 4G LTE cell modem.

The JEMWARE Configuration Software is so easy to use that most can learn the basics of configuring the meter in one hour of training and after a full day, you can gain enough expertise to build your own configurations.

The JEMStar II can be provided in socket, switchboard, A-base and several retrofit packages for easy plug and play of replacement legacy meters. 

Now CAISO and ERCOT approved.

Communications

With the ability to have up to seven communication ports, the tracking of the port status and protocol selections is simplified with our graphical 'heads-up display' on the meter, which shows; which ports are installed and configured, which are in use and which require attention.

The two independent Ethernet ports have separate IP addresses so end users can allow access to third parties without breaching their own secure network.

Each Ethernet port can be addressed for multiple users and protocols operating simultaneously with permissions given to specific functions.

The 4G LTE internal Cell Modem can support up to eight simultaneous connections using different communication protocols. 

Real-Time Site Monitoring

The meter site can be monitored for outages, power quality anomalies and any change in your power.

Real-time alarm notification is provided using web-based JSON messages.

The site data can be fed into 'cloud based' applications moving you into the Internet of Things (IoT) world.

Metering wiring connections can be checked at the meter via color phasor diagram and alert you when wiring is mis-connected or phase angles exceed preset limits.

The phasor display can also be viewed remotely utilizing our JEMWARE software.

Power Quality

The JEMStar II is equipped with Sag/Swell/Outage recordings that store the time, date, duration and site conditions.

For advanced power quality analysis, there is an option to record high-speed RMS measurements and waveform data from pre-selected triggers.

Continuous recording of harmonics, flicker and other power measurements are provided in the 400 channel log with enough memory to store several months of data.

Power quality data resides in a PQDIF file format on the meter. It can automatically be exported for easy analysis with our software or third-party applications.

JEMStar II Retrofit

We've designed our JEMStar II to fit into an existing legacy meter enclosure (short or tall) and connect to the existing wiring for a plug and play replacement option.

This takes the hassle out of finding a way to fit your new meter into an existing cutout and the extra time to update your drawings and rewire the meter.

Utilizing our retrofit offers you the many advanced features that were not available on previous models and can save you more than $1,000 when compared to the cost of installing new meters.

Our retrofit is available on the following meters:
  • SCI JEM2, JEM10 and JEMStar
  • GE DS63, DSW63, DS64, DSW64
  • Quantum Q121, Q220
  • TransData MarkV
  • L&G Quad4
  • Westinghouse D2B, D4B
Features
  • High accuracy - 0.05% for 10 years
  • NERC CIP compliant - Secure access and audit logs for all access attempts
  • 1 GB of non-volatile memory to store metering and power quality data
  • Up to seven communication ports
  • Easy to configure, operate and upgrade
  • Graphic color display and user menu - View and edit configurations
  • Six-channel digital input/output and four-channel Analog input/output
  • Flexible design -Easily replaces many legacy meters

Specifications

Power Quality Recordings

  • Sag/Swell/Outage (Standard)
  • High Speed RMS (Optional)
  • Waveform Capture (Optional)
  • Harmonic Recording (Optional)
  • Flicker Measurement (Optional)
  • Measurement Log (Optional)
  • Trigger Selections (used for alarm logging and PQ recording)

Sag/Swell/Outage

  • Record Event Time, Date, Duration
  • Record phase that triggered
  • Record Min/Max./Avg V, A, Pf, THD

High Speed RMS

  • Record voltage and current per phase
  • 120 Hz Recording Rate
  • Configurable Trigger: Pre and post event recording, max 60 second recording per event

Waveform Capture

  • Record voltage and current phase
  • 16 Samples/Cycle Recording Rate: Max. 960 cycles recording per event
  • 128 Samples/Cycle Recording Rate: Max. 240 cycles recording per event
  • 512 Samples/Cycle Recording Rate: Max. 30 cycles recording per event
  • Configurable Trigger: Pre and post event recording

Harmonic Recording

  • Record individual voltage and current harmonic per phase up to 64th
  • Record magnitude and phase angle

Flicker Measurement

  • Pst and Plt
  • Pinst (instantaneous)

Measurement Log

  • 8 logs of 50 measurements each
  • Recording Interval: 150/180 cycles to 120 minutes
  • Min/Max./Avg Measurements

Trigger Selections (Used for Alarm Logging and PQ Recording)

  • Sag/Swell
  • Transient Trigger
  • Rapid Voltage Change
  • Interruptions
  • THD, TDD, Flicker
  • Phase Loss, Phase Rotation
  • Any instantaneous measurement (over/under)
  • Digital Inputs

Meter Forms

  • Meter Forms: 5, 6, 8, 9, 45, Universal

Voltage Inputs

  • Voltage: 55 to 306 Vac (L-N) 95 to 530 Vac (L-L)

Currents Inputs

  • 1 amp: ANSI Class 2
  • 5 amps: ANSI Class 10
  • 10 amps: ANSI Class 20
  • Burden: 0.5 VA Max.
  • Overload: 1.5x rated Class Current Continuous
  • Starting Current: 0.002 A
  • Frequency Range: 45 - 55 Hz, 55 - 65 Hz

Auxiliary Power

  • S-base and A-base: Self Powered via all three Phases: 55 - 530 Vac, External Aux Power Option: 55 - 530 Vac or 90 - 300 Vdc, 19 - 58 Vdc option
  • Switchboard: Aux Power: 55 - 530 Vac or 90 - 300 Vdc, 19 - 58 Vdc option
  • Auxiliary Power Burden: 25 VA Max.

Accuracy

  • Watt Hour: 0.05 % reading (0.02 % typical)
  • Volts, Amps: 0.04 % reading
  • Frequency: 0.001 Hz

Measurements

  • Bi-directional, 4 quadrant
  • Energy, Instantaneous, per Phase Values
  • Min/Max./Avg values
  • Demand: Peak, Present, Past, Thermal and Coincident
  • TOU: 8 rates/day, 4 season
  • TLC, LLC: per Phase, Delivered and Received, Transformer Factors or % Loss

Measurement Logging (Optional)

  • 8 groups x 50 Channels
  • Recording Interval: 150/180 Cycle to 120 minutes
  • Maximum 203 days of Storage of 400 Channels @ 10-minute Recording Interval

Registers

  • 50 Normal, 50 Alternate, 50 Test

Load Profile

  • 16 Channels Storage
  • 1 - 60-minute Intervals
  • Values Stored in Scalable Counts or 32-bit Engineering Units
  • Optional Second Independent 16 Channel LP Group
  • Maximum 365 days Storage of 32 Channels @ 15-minute Recording Intervals

Time Sync

  • Internal Clock: .05 second/day accuracy
  • 50/60 Hz Line Frequency
  • External Time Sync Options: IRIG-B, NTP

Internal I/O

  • Digital I/O: 6-channel Selectable as Input or Output. Isolated Power Supply for Digital Inputs
  • Analog Output: 4-Channel, 0 - 1 mA or 4 - 20 mA

Digital Input Rating

  • Form A or KYZ
  • Maximum Voltage 40 Vdc

Digital Output Rating

  • Form A or KYZ
  • Maximum Open-Circuit Voltage: 200 Vdc or peak AC
  • Maximum Switching Current, 50 mA

Communications (7 Ports Available)

  • Port 1: Optical (Standard) • Type 2: 19,200 baud
  • Port 2: RS-232 Serial (Optional)• User Configurable: 200 to 38,400 baud
  • Ports 3 and 4: RS-232/485 Serial (Optional), User Selectable: RS-232/485, User Configurable: 300 to 38,400 baud
  • Port 5: Internal Analog Modem (Optional), 56,000 baud
  • Port 5: 4G LTE Internal Cellular Modem - Verizon, Sprint, AT&T, Rogers, T-Mobile, Internal and External Antennas, Supports APN and Whitelist of IP Addresses, Supports up to 8 Simultaneous Connections
  • Ports 6 and 7: Ethernet (Optional) - 100 BaseT, Unshielded Twisted Pair, DHCP or Fixed IP Address, Up to 12 Simultaneous Connections, WEB Server
  • Communication Protocols: Modbus RTU, Modbus TCP/IP, DNP 3.0, ANSI Tables, IEC 61850 (Optional), JEM Binary, DLMS

Meter Display

  • 4.3” (109.2 mm) Color Graphic LCD
  • Registers, Phasor Diagram, Diagnostics
  • User Menu Configuration

Mechanical

  • Case Styles: Socket Connected (S-base), Small Switchboard Case, Bottom Connected (A-base), Meter Retrofits (JEM-2 and others)
  • Size & Weight: S-base: 5.5 pounds (2.5 kg), A-base: 7.5 pound (3.4 kg), Switchboard: 11.5 pounds (5.2 kg)
  • Meter Retrofits: AMETEK: JEM 2, JEM 10, JEMStar, DS63, DS63W, DS64, DS64W, D2B, D4B (Short and Tall), Quantum Q121, Q220, Mark V, Quad 4

Environment

  • Operating Temperature: -22° F to 185° F (-30° C to 85° C)
  • Storage Temperature: -40° F to 185° F (-40° C to 85° C)

Electrical Standards

  • Fast Transient: IEC 61000-4-4
  • Radiated/Conducted Emissions: IEC 61000-4-3, IEC 61000-4-6
  • Surge Immunity: IEC 61000-4-5
  • Electrostatic Discharge: IEC 61000-4-2
  • Surge Withstand (SWC): IEEE Standard C37.90.1

Agency Standards

  • ANSI Standard C12.20-2010
  • IEC 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-5, 61000-4-6, 61000-4-12
  • IEC 61000-4-30 Class A Ed 3.0
  • IEEE C37.90.1
  • IEC 62053-22, IEC 62053-24 (Accuracy)

Industry Approvals

  • CAISO
  • ERCOT
  • NYPSC
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more