155 Series Mass Flow Computer

Brand: Kurz Instruments

The Series 155 Mass Flow Computer is available in five models, depending on the number of flow meters and sensors in your flow meter system.

The Series 155 Mass Flow Computer integrates the functions of temperature and flow measurement, closed loop flow control, flow totalization, alarms, input/output calibration, and data acquisition for up to 22 sensors.
Features
  • Up to 22 sensor inputs for mass flow rate, temperature and 4-20 mA reference inputs
  • Multipoint calibration factor for each meter
  • Ability to group one or more inputs as a meter and to define a meter as the sum/ difference of other meters, for up to 16 meters
  • User-defined meter ID and flow area
  • User-selectable digital filtering for all input channels
  • Built‐in flow totalizers and elapsed time
  • Built-in field calibrators
  • Automatic sensor out-of-tolerance indication, alarm, and re-averaging for multipoint flow elements
  • Up to eight 4-20 mA outputs
  • Up to eight 5-amp alarm relays
  • Choice of optically isolated loop-powered or self-powered 4-20 mA outputs
  • Velocity-temperature mapping (VTM) for wide ranging process temeprature and velocity
  • RS-232C communication port for terminal operation and setup

Specifications

Accuracy

  • 12-bits
  • 13.2-bits

Approvals & Certifications

  • ISO 9001

Approvals & Certifications

  • ATEX
  • CE Compliance Light Industrial
  • CSA
  • EMC
  • EMI: EN 50081-2 for Emissions, 50082-2 for Immunity & EN 61000-4-5 for Surges
  • IEC 79-15, Ex NC II T4 (Class I, Div. 2, Grade A, B, C, D, T4)
  • LVD
  • NAMUR NE43
  • PED
  • RoHS
  • WEEE

Communication

  • Baud Rate: 9600 bit/sec
  • RS-232C
  • RS-485

Environmental Protection

  • NEMA 4
  • NEMA 4X
  • NEMA 7

Humidity

  • 10 to 90 % Relative Humidity, Non-Condensing

Input

  • 0 to 5 Vdc, 13.2-bits Accuracy, ± 30 ppm/°C

Operating Temperature

  • -25° to 60° C (-13° to 140° F)

Output

  • 0-5 V, 250 ohms Min. Load Impedence ± 30 ppm/°C
  • 4-20 mA, Isolated, 500 Vac or 707 Vdc
  • 7-50 V Compliance at 24 Vdc Rmax = 850 ohms
  • Non-Isolated, Rmax = 400 ohms, ± 110 ppm/°C

Power

  • 115/230 Vac ± 10 % 50/60 Hz
  • 24 Vdc ± 10 %

Relay Output

  • 5 A, 24 Vac/dc, Sealed

Resolution

  • 12-bits
  • 18.2-bits

Time Constant

  • 0.1 second Per Channel + 0.2 second
  • Filter Time Constant: 0 to 3600 seconds

Update Time

  • Display Update: Every 2 seconds

  • Stack & Flue Gas
  • Coal Pulverizer Air
  • Cement Plants
  • Nuclear Power Plants
  • EPA & AMS Emissions Monitoring
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more