Yodify Product Library
Instantly add the Model KX Flush Mount Pressure Transducer and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Model KX Flush Mount Pressure Transducer
Brand: Ashcroft IncThe Ashcroft® KX Pressure Transmitter combines benefits of thin film performance with the utility of a flush-mounting sensing diaphragm.
The small sensing area and low internal volume assure accurate measurement under severe conditions. An ideal product for use with process media that can clog standard instrument connections.
Features- Available with PMC adapter
- Flush-mounted integral 316 stainless steel diaphragm
- Stainless steel NEMA 4X enclosure
- Current/voltage output
Specifications
Brand
Accuracy
- ± 1 % of Span
Approvals & Certifications
- UL
BSP Connection
- G 1/2” Male
Burst Pressure
- 300 % of Full Scale
- 800 % of Full Scale
Compensated Temperature
- -29° to 71° C (-20° to 160° F)
Connection Material
- 316 Stainless Steel
Current
- Supply Current: < 3 mA for Voltage Output
Diaphragm Material
- 316 Stainless Steel
- 316Ti Stainless Steel
Electrical Connectors
- 1/2” NPT Male Conduit with 36” Cable Leads
- DIN 43650-Typical Connector
Enclosure, Body Material
- 300 Series Stainless Steel
- Stainless Steel
Environmental Protection
- IP66
- NEMA 4X
Fill Material
- Halocarbon
- Silicone
Humidity
- 95 % Relative Humidity, Non-Condensing
Hysteresis
- ± 0.75 % of BFSL
Insulation Resistance
- 100 megaohms at 50 Vdc
Mounting
- Flush Mounted
Non-Linearity
- ± 0.75 % of BFSL
Non-Repeatability
- ± 0.75 % of BFSL
NPT Connection
- 1/2” NPT Male
Operating Temperature
- -29° to 82.2° C (-20° to 180° F)
Output
- 1-5 Vdc, 3-Wire
- 1-6 Vdc, 3-Wire
- 4-20 mA, 2-Wire
Output Impedence
- 100 ohms
Power Requirement
- 10-36 Vdc Unregulated
Pressure Range
- bar: 0 to 344.7
- kPa: 0 to 34,470
- psi: 0 to 5,000
Proof Pressure
- 150 % of Full Scale
- 200 % of Full Scale
Shock
- 20 G, 20 milliseconds Shock in Any Axis
Span & Zero Effect
- ± 0.04 % of Span/°F
Storage Temperature
- -53° to 121° C (-65° to 250° F)
Vibration Effect
- < ± 0.1 % of Full Scale (0 to 400 Hz at 20 G)
- Pulp & Paper
- Pumping Processes
- Spray Booths
- Wastewater