DM3400 Series Digital Indicator

Brand: Status Instruments

The DM3400 series uses proven technology to accept all commonly used temperature or process inputs.

Engineering units are displayed on a high efficiency Red LED display that provides excellent readability. The DM3410 takes inputs directly from Pt100 or Thermocouple sensors for Temperature indication.

The DM3420 current and voltage for Process indication. The DM3420 also has a transmitter power supply built in for excitation of 2-Wire (4 to 20) mA process transmitters.

The highly innovative case design enables output option ‘Pods’ to be easily installed without the need for dismantling or recalibration.

'Plug and Play' Pods are available covering:
  • POD-02 2 x Relay outputs
  • POD-03 Active or Passive Isolated re-transmission ((0 to 10) mA, (0 to 20) mA, (4 to 20) mA)
A maximum of 2 POD outputs can be fitted to each indicator. The indicator provides a transmitter power supply on the output to excite the POD-03 current retransmission.

Output combinations are
  • Dual Relay Pod and Retransmission Pod
  • Dual Relay Pod and Dual Relay Pod
  • Dual Relay Pod
  • Retransmission Pod
The front panel is sealed to IP65 and the case has a moulded in rubber gasket enabling it to seal to the panel maintaining the IP65 rating, ideal for installing it in 'dusty' areas or where low pressure jets of water are used to clean down equipment.

The unit is programmed using the three push buttons on the front panel where the user is guided through the configuration process.

No Part Numbers & SKUs found

Specifications

Accuracy

  • 0.05 % of Full Scale (Process Indicator)
  • Cold Junction Error: ± 0.5° C (± 0.9° F) (Universal Temperature Indicator)
  • Cold Junction Tracking: 0.05° C/°C (Universal Temperature Indicator)
  • Isolated Re-Transmission: 0.07 % of Full Scale

Approvals & Certifications

  • Electrical Safety: UL BS EN 61010-1, Flammability: UL 94VO
  • EMC BS EN 50081-1 (Emissions), BS EN 50082-2 (Susceptibility)
  • Flammability: IEC 707 FV0

Consumption

  • 6 VA, Max.

Current

  • 0-20 mA (Process Indicator)
  • Excitation Current: 300-550 µA (Universal Temperature Indicator)
  • Ripple Current: < 3 µA

Display

  • 4-Digit Red LED (14.2 mm High/High Intensity)
  • -999 to 9,999

Electrical Connectors

  • Termination: Screw Terminal

Electrical Contacts

  • 2 x Changeover Relays Common Wiper

Environmental Protection

  • Sealing: Panel IP65

Excitation Voltage

  • 24 V ± 5 % at 50 mA (Process Indicator)

Humidity

  • 10 to 90 % Relative Humidity, Non-Condensing

Indication

  • 4 Alarm Red LED Indicators 2.5 mm High Numeric

Input Impedance

  • Current: 47 ohms (Process Indicator)
  • Voltage: 1 Megaohm (Process Indicator)

Isolation

  • 500 Vac: Breakdown Isolation, Input/Output RMS (Galvanically Isolated)

Linearization

  • Linear (Process Indicator)
  • Square Root (Process Indicator)

Load

  • Maximum

Materials of Construction

  • ABS/Polycarbonate

Measurement Accuracy

  • RTD: 0.1° C (32.18° F) ± 0.05 % of Reading (Universal Temperature Indicator)
  • Thermocouple: ± 0.04 % of FRI ± 0.04 % of Reading or 0.5° C (0.9° F), whichever is greater (Universal Temperature Indicator)

Operating Temperature

  • -30° to 60° C (-22° to 140° F)

Output

  • 0 to 23 mA

Output Load

  • 1 Kiloohm

Power

  • AC - Max.
  • DC - Max.

Power Supply

  • S1: 90-253 Vac, (50/60 Hz)
  • S2: 20-35 Vdc

Power Supply Effect

  • Voltage Effect: 0.2 μA/V

Resistance

  • Maximum
  • Sensor: 18 to 390 ohms (Universal Temperature Indicator)

Resistance Effect

  • Lead Resistance Effect: 0.002° C/ohms (Universal Temperature Indicator)

RTD Type

  • Pt100

Sensor, Probe Type

  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple

Stability

  • 1 µA/°C

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Supply Voltage

  • 0-10 V (Process Indicator)
  • Maximum

Temperature Range

  • Cold Junction Range: -30° to 60° C (-22° to 140° F) (Universal Temperature Indicator)
  • Sensor: -200° to 850° C (-328° to 1,562° F) (Universal Temperature Indicator)

Thermal Drift

  • Span: 0.01 %/°C
  • Zero: 0.008° C/°C (Universal Temperature Indicator)
  • Zero: 0.1 µV/°C

Time Constant

  • Filter Off: < 1 second (to 63 % of Final Value)

Update Time

  • 250 milliseconds, Max.
  • Warm-Up Time: 120 seconds to Full Accuracy

Voltage

  • Maximum