Brand: Kayden Instruments

The Kayden CLASSIC 814 Flow, Level, Interface Switch & Transmitter features a precision-welded, highly accurate stainless steel sensor.
 
Ideal for liquids, gases, and slurries in a clean or dirty process.
 
The CLASSIC 814 Retractable Packing Gland is available with a Raised Face or RTJ flange in a wide range of flange sizes and ANSI ratings for low- and medium-pressure applications.
 
All Kayden models feature a rugged flameproof enclosure with blind or lens covers available.
 
  • Process Connection
    • Retractable Packing Gland
    • Raised Face or RTJ Flange
  • Adjustable Set Point Range
    • 0-254 feet/s
    • 0-77 meters/s
  • Insertion 'U' Length
    • inch  2.5" to 120" in 1/2" increments
    • cm  6.4 to 305  in 1 cm increments
  • Input Power
    • 12-24 Vdc & 115-230 Vac, 50-60 Hz
  • Operating Pressure - Maximum
    • Dependent on Flange Rating
  • Temperature Range - Sensor
    • -40° C to 160° C
    • -40° F to 320° F
  • Local Enclosure
    • Aluminum Flameproof
    • 1" Female NPT Conduit Connection
  • Local Enclosure Cover
    • Blind or Glass Lens Flameproof
  • Materials of Construction - Sensor and Flange
    • 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays - SPDT
    • 4-20 mA
    • Modbus
  • Approvals
    • CSA
    • Single Seal
    • NACE
    • NEMA 4, 4X, 6P, IP65/67

1 - 12 of 23 Part Numbers
814-RAA-131AT-I0025-C1B0A-1E
814-RAA-131AT-I0025-C1B0A-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 2.5"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 1-1/2" MNPT
    • ANSI: 150

  • Flange Materials: 316 Stainless Steel 
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 2.5", 6.35 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • UL, CSA, Single Seal, NACE, NEMA 4
814-RAA-131AT-I0150-C1B0A-1E
814-RAA-131AT-I0150-C1B0A-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 15"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 1-1/2" MNPT
    • ANSI: 150

  • Flange Materials: 316 Stainless Steel 
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 15", 38.1 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • UL, CSA, Single Seal, NACE, NEMA 4
814-RAA-131AT-I1200-C1B1B-1E
814-RAA-131AT-I1200-C1B1B-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 120"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Remote Electronics, Approvals: C CSA Us (UL Standard
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 1-1/2" MNPT
    • ANSI: 150

  • Flange Materials: 316 Stainless Steel
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 120", 304.8 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Flameproof Blind
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • UL, CSA, Single Seal, NACE, NEMA 4
814-RAA-131AX-I0150-C1B0A-9E
814-RAA-131AX-I0150-C1B0A-9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, PRetractable Packing Gland, 1-1/2" 150# RF SST Flange,15"U Length, 316 SST Sensor,Local Electronics Enclosure with Blind Cover, Approvals: FM
  • Sensor Material - 316/316L Stainless Steel
  • Flange Material - 316/316L Stainless Steel
  • Process Connection Flange Type - Raised Face
  • Flange Size & ANSI Rating - 1-1/2" 150#
  • Retraction Assembly - Medium Pressure, 316 Stainless Steel (MWP 500 psi)
  • Insertion 'U' Length - 15 Custom 'U' Length: Inches
  • Cover for Local Enclosure - Blind Cover
  • Remote Electronics Enclosure & Cover - Not Required
  • Agency Approvals - FM
814-RAA-131AX-I0260-C1B0A-9E
814-RAA-131AX-I0260-C1B0A-9E
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, P/G, 1-1/2"150# RFSST, 26"U, SST, Blind, FM
814-RAA-131ET-I0140-C1G0A-1E
814-RAA-131ET-I0140-C1G0A-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF Carbon Steel Flange, 14"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 1-1/2" MNPT
    • ANIS: 150
  • Flange Materials: Carbon Steel
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 14", 35.5 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Glass Cover
  • Remote Electronics Enclosure and Cover: Not Selected
  • Wetted Materials:
    • Standard: 316 Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus
  • UL, CSA, Single Seal, NACE, NEMA 4
814-RAA-141AJ-M2000-C1G0A-9E
814-RAA-141AJ-M2000-C1G0A-9E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 2" 150# RF SST Flange, 200 cm U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 2" MNPT
    • ANIS: 150

  • Flange Materials: 316 Stainless Steel
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 78.7", 200 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof GlassCover
  • Remote Electronics Enclosure and Cover: Not Selected
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • FM, NACE, NEMA 4
814-RAA-141AT-I0060-C1B0A-1E
814-RAA-141AT-I0060-C1B0A-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 2" 150# RF SST Flange, 6"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:
    • Flanged Retractable Packing Gland Raised Face
    • 2" MNPT
    • ANSI: 150

  • Flange Materials: Stainless Steel
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Insertion 'U' Length: 6", 5.01 cm
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
  • Local Enclosure: Aluminium Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:
    • Standard: 316 Stainless Steel

  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus

  • UL, CSA, Single Seal, NACE, NEMA 4
814-RAA-141AT-I0160-C1B0A-1E
814-RAA-141AT-I0160-C1B0A-1E
KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 2" 150# RF SST Flange, 36"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
  • Process Connection:


    • Flanged Retractable Packing Gland Raised Face
    • 2" MNPT
    • ANSI: 150


  • Flange Materials: Stainless Steel


  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s


  • Insertion 'U' Length: 16", 40.6 cm


  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz


  • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar


  • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F


  • Local Enclosure: Aluminium Flameproof, 1" FNPT


  • Cover: Flameproof Blind Cover


  • Remote Electronics Enclosure and Cover: Not Required


  • Wetted Materials:


    • Standard: 316 Stainless Steel


  • Outputs/Communications:
    • Two Independent Relays (SPDT), 4-20 mA, Modbus


  • UL, CSA, Single Seal, NACE, NEMA 4
  • 814-RAA131AT-I0140-C1G0A1E
    814-RAA131AT-I0140-C1G0A1E
    KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 14"U Length, 316 SST Sensor, Local Electronics Enclosure with Glass Lens Cover, Approvals: C CSA Us (UL Standards)
    • Process Connection:
      • Flanged Retractable Packing Gland Raised Face
      • 1-1/2" MNPT
      • ANSI: 150

    • Flange Materials: 316 Stainless Steel 
    • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
    • Insertion 'U' Length: 14", 35.5 cm
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
    • Local Enclosure: Aluminium Flameproof, 1" FNPT
    • Cover: Flameproof Glass Lens Cover
    • Remote Electronics Enclosure and Cover: Not Required
    • Wetted Materials:
      • Standard: 316 Stainless Steel

    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus

    • UL, CSA, Single Seal, NACE, NEMA 4
    814-RAA131AT-I1200-C1B1A1E
    814-RAA131AT-I1200-C1B1A1E
    KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 270"U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
    • Process Connection:
      • Flanged Retractable Packing Gland Raised Face
      • 1-1/2" MNPT
      • ANSI: 150

    • Flange Materials: 316 Stainless Steel
    • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
    • Insertion 'U' Length: 120", 304.8 cm
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
    • Local Enclosure: Aluminium Flameproof, 1" FNPT
    • Cover: Flameproof Blind Cover
    • Remote Electronics Enclosure and Cover: Flameproof Blind
    • Wetted Materials:
      • Standard: 316 Stainless Steel

    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus

    • UL, CSA, Single Seal, NACE, NEMA 4
    814-RAA131AT-M2700-C1B0A1E
    814-RAA131AT-M2700-C1B0A1E
    KAYDEN® CLASSIC® Thermal Flow, Level, Interface Switch, Modbus, Retractable Packing Gland, 1-1/2" 150# RF High-Hub SST Flange, 270" U Length, 316 SST Sensor, Local Electronics Enclosure with Blind Cover, Approvals: C CSA Us (UL Standards)
    • Process Connection:
      • Flanged Retractable Packing Gland Raised Face
      • 1-1/2" MNPT
      • ANSI: 150
    • Flange Materials: 316 Stainless Steel
    • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
    • Insertion 'U' Length: 270cm, (106.3")
    • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
    • Operating Pressure (Maximum): 3480 psi, 24000 kPa, 240 bar
    • Temperature Range (Sensor): -40°C to 160°C, -40°F to 320°F
    • Local Enclosure: Aluminium Flameproof, 1" FNPT
    • Cover: Flameproof Blind Cover
    • Remote Electronics Enclosure and Cover: Not Selected
    • Wetted Materials:
      • Standard: 316 Stainless Steel
    • Outputs/Communications:
      • Two Independent Relays (SPDT), 4-20 mA, Modbus
    • UL, CSA, Single Seal, NACE, NEMA 4
    1 - 12 of 23 Part Numbers

    Specifications

    Applications

    • Flow
    • Interface
    • Level

    Principle of Operation

    • Thermal, Calorimetric

    Insertion 'U' Length - Custom

    • 6.4 cm to 305 cm (in 1 cm increments)
    • 2.5” to 120” (in 1/2” increments)

    Flange Type

    • RF - Raised Face
    • RTJ - Ring Typical Joint

    Flange Class

    • 300#
    • 600#
    • 900#
    • 150#

    Flange Size

    • 1" DN 25
    • 1-1/2" DN 40
    • 2" DN 50
    • 3" DN 80
    • 4" DN 100
    • 5" DN 125
    • 6" DN 150
    • 8" DN 200
    • 10" DN 250

    Flange Material

    • 316 Stainless Steel

    Wetted Materials

    • 316/316L Stainless Steel
    • Highly Saturated Nitrile (Pressure Seal-Sensor)

    Sensor Construction

    • All-Welded Construction

    Process Connection Style

    • Flanged Retractable

    Retraction Assembly

    • Low Pressure with Security Chain, 316/316L Stainless Steel (MWP 125 psi)
    • Low Pressure: 316/316L Stainless Steel (MWP 50 psi)
    • Medium Pressure: 316/316L Stainless Steel (MWP 500 psi)

    Operating Pressure Maximum - Sensor

    • Per Flange Rating, ASME B16.5

    Operating Temperature - Sensor

    • -40° to 160° C (-40° to 320° F)

    Operating Temperature - Electronics

    • -55° to 65° C (-67° to 149° F)

    Switch Point Range

    • Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
    • Hydrocarbon-based Liquids: 0.01 - 5.0 fps, 0.003 - 1.50 mps
    • Water-based Liquids: 0.01 - 3.00 fps, 0.003 - 0.9 mps

    Response Time

    • Approximately 0.5 to 30 seconds

    Accuracy

    • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
    • Level Service: ± 0.64 cm (0.25”)

    Switch Type

    • 2 SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

    Input Power

    • 12-24 Vdc, 115-230 Vac, 50/60 Hz / Universal Power Input
    • Power Consumption: Max.

    Output

    • 4-20 mA (Thermal Signal, Scaleable)

    Communication

    • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
    • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

    Approvals & Certifications

    • CRN - Canadian Registration Number - the Kayden Classic 814 does not have a CRN Number
    • CSA
    • CSA - Local (Sensor) Enclosure Flameproof: Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Temperature Code: T3 Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
    • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂) Temperature Code: T3

    Electronics - Standard Features

    • *Configurable only from the Kayden RCM Software
    • 100 % Digital Design. Electronics are Environmentally Sealed
    • 4-Adjustable Independent Switch Point Timers
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out*
    • Easy Setup: No Mechanical Jumpers or Trim Pots
    • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
    • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
    • Temperature Compensation
    • Temperature Mode*: Process Temperature may be Displayed/Graphed in Flow/Level Mode

    Remote Control & Monitoring Software

    • Adjust Relay Modes
    • Adjust Set Points 1 & 2
    • Load or Save User Settings
    • Lock or Unlock the Display Panel to Protect the Settings
    • Many Other Adjustable Features
    • Modify Heater Settings to Optimize Response Time
    • Monitor Operating Status
    • Operated Via a Personal Computer Locally or from a Remote Control Center
    • Visualize the Actions of the Process Via the Graphical Display

    Environmental Protection

    • IP55
    • NEMA 4 / IP55

    Local Enclosure Conduit Connection

    • 1” NPT Female Conduit Connection

    Local Enclosure & Cover Material

    • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

    Local Enclosure Cover

    • Buna-N O-Ring on Cover
    • Blind Cover - Flameproof
    • Glass Lens Cover - Flameproof

    Local Enclosure & Cover Finish

    • Powder-Coated Polyester TGIC

    Remote Electronics Enclosure Cover

    • Glass Lens Cover - Flameproof

    Remote Electronics Enclosure & Cover Finish

    • Powder-Coated Polyester TGIC

    Sensor, Probe Style

    • Insertion

    Storage Temperature

    • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)

    Flow
    • Ammonia Storage
    • Biogas Flow
    • Catalysis Vessels
    • Chemical Injection & Additive Flow Monitoring
    • Chemical Reactors
    • Chlor-alkali Processes
    • Compressors
    • Condensers
    • Deionization Tanks
    • Digester Gas Flow
    • Distillation Columns
    • Drain Line Flow
    • Emergency Eye Wash & Shower Stations
    • Fermentation Vessels
    • Flare Gas Monitoring
    • Flare Knock-out Drums
    • Flow Monitoring & Verification
    • Heat Exchangers
    • Heat Recovery Steam Generator (HRSG) - Power & Utilities
    • High Pressure Flows
    • Leak Detection
    • Lube Oil Systems
    • Monitoring Purge Air Flow
    • Natural Gas to Boilers
    • Pumps
    • Reboilers
    • Refinery Flow Applications
    • Relief Valve & Rupture Disk Flow Monitoring
    • Remote Indication of Flow via Analog Output & Digital Communications
    • Pump Protection - Dry Alarm
    • Tank Blanketing
    • Tank Overflow Protection
    • Tanker Loading & Unloading
    • Water & Wastewater
    • Vaporizers
    • Vent Monitoring

    Level
    • Biogas Dehydration
    • Blending Operations
    • Carbon Slurry Level
    • Compressor Scrubber
    • Compressor Waste Liquid
    • Condensate Receiver Tanks
    • Cooling Tower Basins
    • Crude Desalting
    • Crude Dehydration
    • Deionization Tanks
    • Digester Blow Tanks
    • Free Water Knock-out Tanks - High, Low and Interface Level
    • Geothermal - Degasser Tanks
    • Geothermal - Steam & Brine Separators
    • Leak Detection (Accumulation Reservoir)
    • Lime Slurry Level
    • Mixing & Blending Systems
    • Oil Separators & Treaters - High, Low & Interface Level
    • Production Fluid Storage
    • Pulp Bleaching Towers
    • Pulp Digesters
    • Pulp Storage
    • Pulp Washing Systems
    • Sampler Systems
    • Sand Separators
    • Scrubber Vessels
    • Storage Tanks
    • Sumps - All Types of fluids: Water, Oil, etc.
    • Surge Tanks
    • Tank Overflow
    • Turpentine Recovery
    • Vapor & Liquid Separation
    • Vapor Recovery

    Interface
    • Crude Desalting
    • Interface Control in Separation Vessels
    • Interface Detection
    • Interface Control & Level Detection in Settling Vessels
    • Liquid-Liquid Extraction - LLX

    Media
    • Liquids, Air & Gases
    • Slurries
    • Corrosive Liquids

    Areas
    • Flameproof, Hazardous & General-Purpose Areas

    IDEAL PROCESS CONDITIONS FOR FLOW

    Liquids
    • Consistent Process Composition & Temperature
    • Sufficient Straight Run Flow Profile (minimizes turbulence)
    • Recommended Minimum of 5 Pipe Diameters from any Disturbance

    Air & Gas
    • Consistent Process Composition & Temperature
    • Sufficient Straight Run Flow Profile (minimizes turbulence)
    • Clean and Dry

    Slurries
    • Consistent Process Composition & Temperature
    • Sufficient Straight Run Flow Profile (minimizes turbulence)

    Emulsion
    • Consistent Process Composition & Temperature
    • Sufficient Straight Run Flow Profile (minimizes turbulence)

    UNDESIRABLE PROCESS CONDITIONS FOR FLOW
       
    Liquids
    • Inconsistent Process Composition or Temperature
    • Insufficient Straight Run
    • Aerated Fluids
    • Turbulence

    Air & Gas
    • Inconsistent Process Composition or Temperature
    • Wet or Saturated Air & Gas

    Slurries
    • Inconsistent Process Composition or Temperature
    • Insufficient Straight Run
    • Aerated Fluids
    • Turbulence

    Emulsion
    • Inconsistent Process Composition & Temperature
    • Insufficient Straight Run
    • Aerated Fluids
    • Turbulence

    Solids
    • Dry granulated processes are NOT good candidates for thermal switches