Yodify Product Library
Instantly add the ADMAG CA Magnetic Flow Meter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
ADMAG CA Magnetic Flow Meter
Brand: Yokogawa Electric CorporationThe ADMAG CA magnetic flow meter adopts a system to pick up the electromotive force generated in a fluid by electrodes provided outside a ceramic pipe through the capacitance of the pipe.
In addition, the flow meter employs a prominent high-frequency excitation method that reduces flow noise in low conductivity fluid.
ADMAG CA magnetic flow meter is excellent at measurement in ultra-low conductivity fluids down to 0.01 microS/cm, adhesive fluids, or slurry fluids.
Since ADMAG CA employs a non-wetted electrode construction, picking up the signal voltage by electrode plates provided outside a ceramic pipe through the capacitance of the pipe.
Features- Ultra Low Conductivity Measurements
- Capacitance type electrodes and very high impedance amplifier of ADMAG CA makes ultralow conductive fluid measurement possible. This combined technology allows the ADMAG CA to measure fluids with conductivity levels as low as 0.01μS/cm.
- Accuracy Specification
- The ADMAG CA offers accuracy up to 0.5% of flow rate.
- Non-wetted Electrodes
- The ADMAG CA utilizes a non-wetted electrode design. Instead, electrode pickup plates are placed on the measuring tube to pick up and measure the electromotive force. The non-wetted electrodes create an excellent opportunity for use in chemical and slurry applications as it is not affected by the corrosion, coating, ultra-low conductivity, and abrasive issues associated with wetted electrodes.
- This reduces the effect of slurry or process noise, eliminates potential leak paths, and makes it ideal for high coating process applications.
- Ceramic Liner - Excellent for Corrosive Fluid and Abrasive Fluid
- Ceramic liner tubes have many advantages over fluoropolymer (PFA/PTFE) or other liner materials like rubber. ADMAG CA uses alumina ceramic (Al2O3 ) for its ceramic liner tubes, which demonstrates excellent characteristics for a broad range of applications.
- The alumina ceramic (Al2O3 ) used in the ADMAG CA has a purity of 99.9%.
- Resistance to abrasion, ensuring accurate measurements even with highly abrasive slurries
- Resistance to corrosive fluids
- Durability under high temperature and high pressure conditions without additional metal tube
- Coating Resistant
- Non-wetted capacitive electrodes can measure electromotive force through capacitance including coating insulating material, offering steady measurement. The ADMAG CA is ideal for field-proven applications such as latex, reclaimed oil, hot spring water, red mud, and dye which are more difficult to measure with conventional magnetic flow meters.
- Mirror Finished Surface
- By means of a special magnetic polishing process, the inner surface of the ceramic liner tube can be given a mirror finish. This polishing method is advantageous in eliminating problems such as abrasive irregularities and dull edges and will reduce the coating affects of your process. The mirror finished ceramic liner tube has a surface roughness of Ra 0.1 μm.
Specifications
Accuracy
- ± 0.25 % of Span (At Indications Below 50 % of Span)
- ± 0.5 % of Rate (At Indications 50 % of Span or More)
- ± 0.5 % of Span (At Indications Below 50 % of Span)
- ± 1 % of Rate (At Indications 50 % of Span or More)
- ± 1 % of Span
Ambient Temperature Range
- -20° to 50° C (-4° to 122° F)
Approvals & Certifications
- CSA Explosion-proof for Class I, Groups B, C, D, Class II, Groups E, F, G, Class III
- EMC AS/NZS CISPR 11
- FM 3600, FM 3615, FM 3810, Explosion-proof for Class I, Div. 1, Groups A, B, C, D
- FM Dust-Ignition-proof for Class II/III, Div. 1, Groups E, F, G
- TIIS Construction: Ex d E IIC T4 X: Converter, Flameproof Flow Tube, Increased Safety: Gas Group & Temperature Class, IIC T4
Approvals & Certifications
- Calibration
- Hydrostatic Pressure Test
- Material Certificate
Cable Length
- 6,560 feet (2,000 metres) - Max.
Capacity
- 0.22 µF or Less (Including Cable) - Load Capacity
Communication
- BRAIN (Superimposed on a 4-20 mA DC Signal)
Consumption
- 14 W
Damping Adjustment
- Settable from 1 to 200 seconds (63 % Response Time)
Diagnostics
- Converter Failure
- Erroneous Setting
- Flow Tube Failure
Display
- 7-Segment LCD (with No Backlight)
Duty Cycle
- 50%
Electrical Connectors
- ANSI 1/2” NPT Female
- DIN PG13.5 Female
- ISO M20 x 1.5 Female
- JIS G 1/2” Female
- M4 Screw Terminal - Terminal Connection
Electrical Protection
- Lightning Protection
Electrical Rating
- 200 mA (ON)
- 30 Vdc (OFF)
Enclosure Finish
- Deep Sea Moss Green (Equivalent to Munsell 0.6 GY3.1/2.0) - for Cover
- Epoxy Coated
- Frosty White (Equivalent to Munsell 2.5Y8.4/1.2) - for Enclosure/Body (Aluminum Alloy)
- High Anti-Corrosion Coating
- Polyurethane Corrosion-Resistant Coating
Enclosure, Body Material
- Aluminum Alloy
- SCS11 for 0.5” (15 mm) Size - Flow Tube Material
- Stainless Steel
- SUS304 for 1” to 8” (25 to 200 mm) Size - Flow Tube Material
Environmental Protection
- IP66
- IP67
- NEMA 4X
- Water-Proof
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ANSI
- 1-1/2” (DN 40) - 300# ANSI
- 1-1/2” (DN 40) - JIS 10K
- 1-1/2” (DN 40) - JIS 20K
- 1-1/2” (DN 40) - JIS F12 (75M)
- 1-1/2” (DN 40) - PN 10
- 1-1/2” (DN 40) - PN 16
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ANSI
- 1” (DN 25) - 300# ANSI
- 1” (DN 25) - JIS 10K
- 1” (DN 25) - JIS 20K
- 1” (DN 25) - JIS F12 (75M)
- 1” (DN 25) - PN 10
- 1” (DN 25) - PN 16
Flange Size - 1/2” (DN 15)
- 1/2” (DN 15) - 150# ANSI
- 1/2” (DN 15) - 300# ANSI
- 1/2” (DN 15) - JIS 10K
- 1/2” (DN 15) - JIS 20K
- 1/2” (DN 15) - JIS F12 (75M)
- 1/2” (DN 15) - PN 10
- 1/2” (DN 15) - PN 16
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ANSI
- 2” (DN 50) - 300# ANSI
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - JIS 20K
- 2” (DN 50) - JIS F12 (75M)
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 16
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ANSI
- 3” (DN 80) - 300# ANSI
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - JIS 20K
- 3” (DN 80) - JIS F12 (75M)
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 16
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# ANSI
- 4” (DN 100) - 300# ANSI
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - JIS 20K
- 4” (DN 100) - JIS F12 (75M)
- 4” (DN 100) - PN 10
- 4” (DN 100) - PN 16
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# ANSI
- 6” (DN 150) - 300# ANSI
- 6” (DN 150) - JIS F12 (75M)
- 6” (DN 150) -JIS 10K
- 6” (DN 150) -JIS 20K
- 6” (DN 150) -PN 10
- 6” (DN 150) -PN 16
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# ANSI
- 8” (DN 200) - 300# ANSI
- 8” (DN 200) - JIS 10K
- 8” (DN 200) - JIS 20K
- 8” (DN 200) - JIS F12 (75M)
- 8” (DN 200) - PN 10
- 8” (DN 200) - PN 16
Fluid
- 0.01 µS/cm or more - Fluid Conductivity for Sizes 0.5” to 4” (15 to 100 mm)
- 1 µS/cm or more - Fluid Conductivity for Sizes 6” (150 mm) & 8” (200 mm)
- Glycerin + Ethylene Glycol
Function
- Alarm Output
- Instantaneous Flow Rate Display
- Pulse Output
- Span Setting
- Totalizer Display
Gasket Material
- Chloroprene
- Chloroprene Rubber (Between Earth Ring & Process Flange)
- Fluoro Resin PTFE with Filler (Between Flow Tube Body & Earth Ring)
- Fluororubber (Between Flow Tube Body & Earth Ring)
- Non-Asbestos Joint Sheet Sheathed with Fluoro Resin PTFE (Between Earth Ring & Process Flange)
- Viton (Between Flow Tube Body & Earth Ring)
Humidity
- 5 to 80 % Relative Humidity, Non-Condensing - Ambient Humidity
Insulation Resistance
- 100 megaohms at 500 Vdc - between Power Terminals & Each Output Terminal
- 100 megaohms at 500 Vdc - between Power Terminals & Ground Terminal
- 20 megaohms at 100 Vdc - between Each Output Terminal & Ground Terminal
Load
- 3.3 MH or Less (Including Cable) - Load Inductance
Materials of Construction
- PVC - Pipe
Measuring Time
- 20 seconds
Mounting Position
- Horizontal
- Vertical
Nut & Bolt Material
- Carbon Steel
- Stainless Steel
Output
- 4-20 mA DC - Current Output
Power Supply
- 100-130 Vdc
- 20.4-28.8 Vdc
- 80-264 Vac
Pressure Range
- psi: -14.5 to 580 (MPa: -0.1 to 4, bar: -1 to 40) - Fluid Pressure
Process Connection Style
- Wafer
Process Temperature
- 70° to 120° C (158° to 248° F)
Pulse Range
- 0.5 to 100 milliseconds - User Selectable (Pulse Width)
- Output Rate: 0.0001 to 1,000 Pps (When Pulse Output Function is Selected) - Pulse Output Function
Repeatability
- ± 0.1 % of Rate (Min. ± 1 mm/sec)
Resistance
- 0 to 750 ohms - Load Resistance for Current Output (4-20 mA DC)
- 10 kiloohms or Larger at 2.4 kHz - Input Impedance of Receiver Connected to the Receiving Resistance
- 10 ohms or Less - Grounding for TIIS Flameproof Typical, Class A or Class C & JIS Class C, JIS Class A
- 100 ohms or Less - Grounding
- 250 to 600 ohms (Including Cable) - Load Resistance
Rotation
- 180° Rotate Converter
Size
- 0.5” to 8” (15 to 200 mm)
- 5.9” (15 cm) or more (Parallel Wiring Should be Avoided) - Space from Power Line
Supply Voltage
- 1,500 Vac for 1 Minute between Power Terminals & Ground Terminal - Withstanding Voltage
- 120 Vdc - Max.
- 130 Vdc - Max.
- 240 Vac - Max.
- 250 Vac - Max.
Temperature Range
- -10° to 120° C (14° to 248° F) - Fluid Temperature
Torque
- 10.44 In/Lbs or more - Screw Tightening Torque
Wetted Materials
- Alumina Ceramic (99.9 %) - Pipe
- Hastelloy C-276 Equivalent - Earth Ring
- Stainless Steel (SUS316) - Earth Ring
- Titanium - Earth Ring