Yodify Product Library
Instantly add the Cable Glands Ex e Series TMC and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Cable Glands Ex e Series TMC
Brand: R. STAHL AGThe cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
Features- Designed for use in North America
- Version with NPT thread and metric thread
- Operating temperature range: -60 °C … +110 °C
- Class I Zone 1, 21 und Zone 2, 22
- Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
- Worldwide certification, UL, cCSAus, IECEx and ATEX
1 - 12 of 17 Part Numbers
243563
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-20sTMC
- Title Product Variant Technical Data - CMP-20sTMC gland NB M20
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 8.70 - 12.70 mm
- Clamping range max. - 12.70 mm
- Clamping range min. - 8.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 8.70 … 12.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 9.00 … 13.90 mm
- Protrusion length - 46.50 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M20
- Thread standard - metric
- Weight - 0.520 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
243564
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-20TMC
- Title Product Variant Technical Data - CMP-20TMC gland NB M20
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 13.00 - 17.00 mm
- Clamping range max. - 17.00 mm
- Clamping range min. - 13.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 13.00 … 17.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 11.10 … 20.00 mm
- Protrusion length - 52.20 mm
- PVC-shroud - PVC09
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M20
- Thread standard - metric
- Weight - 0.520 kg
- Width across corners - 39.60 mm
- Width across flats - 36.00 mm
243565
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-25TMC
- Title Product Variant Technical Data - CMP-25TMC gland NB M25
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 15.00 - 23.30 mm
- Clamping range max. - 23.30 mm
- Clamping range min. - 15.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 15.00 … 23.30 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 17.00 … 26.30 mm
- Protrusion length - 53.10 mm
- PVC-shroud - PVC10
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M25
- Thread standard - metric
- Weight - 0.520 kg
- Width across corners - 45.10 mm
- Width across flats - 41.00 mm
243566
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-32TMC
- Title Product Variant Technical Data - CMP-32TMC gland NB M32
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 19.70 - 29.20 mm
- Clamping range max. - 29.20 mm
- Clamping range min. - 19.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 19.70 … 29.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 22.00 … 32.20 mm
- Protrusion length - 56.90 mm
- PVC-shroud - PVC13
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M32
- Thread standard - metric
- Weight - 0.520 kg
- Width across corners - 55.00 mm
- Width across flats - 50.00 mm
243567
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-40TMC
- Title Product Variant Technical Data - CMP-40TMC gland NB M40
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 27.50 - 35.20 mm
- Clamping range max. - 35.20 mm
- Clamping range min. - 27.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 27.50 … 35.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 29.50 … 38.20 mm
- Protrusion length - 56.30 mm
- PVC-shroud - PVC15
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M40
- Thread standard - metric
- Weight - 0.590 kg
- Width across corners - 60.50 mm
- Width across flats - 55.00 mm
243568
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-50TMC
- Title Product Variant Technical Data - CMP-50TMC gland NB M50
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 33.50 - 41.10 mm
- Clamping range max. - 41.10 mm
- Clamping range min. - 33.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 33.50 … 41.10 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 35.60 … 44.10 mm
- Protrusion length - 58.60 mm
- PVC-shroud - PVC18
- Sealing material - SOLO LSF
- Thread length - 15.000 mm
- Thread pitch - 1,5 mm
- Thread size - M50
- Thread standard - metric
- Weight - 0.690 kg
- Width across corners - 66.00 mm
- Width across flats - 60.00 mm
254316
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-050STMC
- Title Product Variant Technical Data - CMP-050STMC gland NB NPT 1/2"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 8.70 - 12.70 mm
- Clamping range max. - 12.70 mm
- Clamping range min. - 8.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 8.70 … 12.70 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 9.00 … 13.90 mm
- Protrusion length - 46.50 mm
- PVC-shroud - PVC06
- Sealing material - SOLO LSF
- Thread length - 19.800 mm
- Thread pitch - 14 TPI
- Thread size - NPT1/2
- Thread standard - NPT
- Weight - 0.220 kg
- Width across corners - 33.60 mm
- Width across flats - 30.50 mm
254317
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-050TMC
- Title Product Variant Technical Data - CMP-050TMC gland NB NPT 1/2"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 13.00 - 17.00 mm
- Clamping range max. - 17.00 mm
- Clamping range min. - 13.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 13.00 … 17.00 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 11.10 … 20.00 mm
- Protrusion length - 52.20 mm
- PVC-shroud - PVC09
- Sealing material - SOLO LSF
- Thread length - 19.800 mm
- Thread pitch - 14 TPI
- Thread size - NPT1/2
- Thread standard - NPT
- Weight - 0.280 kg
- Width across corners - 39.60 mm
- Width across flats - 36.00 mm
254318
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-075TMC
- Title Product Variant Technical Data - CMP-075TMC gland NB NPT3/4"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 15.00 - 23.30 mm
- Clamping range max. - 23.30 mm
- Clamping range min. - 15.00 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 15.00 … 23.30 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 17.00 … 26.30 mm
- Protrusion length - 53.10 mm
- PVC-shroud - PVC10
- Sealing material - SOLO LSF
- Thread length - 20.200 mm
- Thread pitch - 14 TPI
- Thread size - NPT3/4
- Thread standard - NPT
- Weight - 0.330 kg
- Width across corners - 45.10 mm
- Width across flats - 41.00 mm
254319
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-100TMC
- Title Product Variant Technical Data - CMP-100TMC gland NB NPT1"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 19.70 - 29.20 mm
- Clamping range max. - 29.20 mm
- Clamping range min. - 19.70 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 19.70 … 29.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 22.00 … 32.20 mm
- Protrusion length - 56.90 mm
- PVC-shroud - PVC13
- Sealing material - SOLO LSF
- Thread length - 25.000 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT1
- Thread standard - NPT
- Weight - 0.500 kg
- Width across corners - 55.00 mm
- Width across flats - 50.00 mm
254320
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-125TMC
- Title Product Variant Technical Data - CMP-125TMC gland NB NPT1 1/4"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 27.50 - 35.20 mm
- Clamping range max. - 35.20 mm
- Clamping range min. - 27.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 27.50 … 35.20 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 29.50 … 38.20 mm
- Protrusion length - 56.30 mm
- PVC-shroud - PVC15
- Sealing material - SOLO LSF
- Thread length - 25.600 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT1-1/4
- Thread standard - NPT
- Weight - 0.590 kg
- Width across corners - 60.50 mm
- Width across flats - 55.00 mm
254321
Designed for use in North America
Version with NPT thread and metric thread
Operating temperature range: -60 °C … +110 °C
Class I Zone 1, 21 und Zone 2, 22
Class I Zone 1 Ex e and Class I Div. 2 groups ABCD
Worldwide certification, UL, cCSAus, IECEx and ATEX
Ambient Conditions
- Ambient temperature - -60 °C ... +110 °C
- Ambient temperature max. - +110 °C
- Ambient temperature min. - -60 °C
Electrical Data
- Ex version - Ex e
Explosion Protection
- Ambient temperature °C - -60 - 110 °C
- Application range (zones) - 1, 2, 20, 21, 22
- ATEX dust certificate - SIRA 07 ATEX 1122 X
- ATEX gas certificate - SIRA 07 ATEX 1022 X
- Certificate EAC - TS RU S-GB.AA87.B.00487
- Dust explosion protection ATEX - II 2 D Ex tD A21
- Dust explosion protection EAC - Ex ta IIIC Da X
- Gas explosion protection ATEX - II 2 G Ex e II
- Gas explosion protection EAC - 1 Ex e IIC Gb X
- Gas explosion protection IECEx - Ex e II
- IECEX gas certificate - IECEx SIR 07.0083 X
- Note - The product certification and certificates can be downloaded from the manufacturer’s homepage (www.cmp-products.com)
General
- Functional Description - The cable glands have a sequential design and, therefore, do not need to be dismantled for installation. A 360° rotary spring establishes secure earthing. They have worldwide certification according to UL, cCSAus, IECEx and ATEX.
- Highlights - Designed for use in North America Version with NPT thread and metric thread Operating temperature range: -60 °C … +110 °C Class I Zone 1, 21 und Zone 2, 22 Class I Zone 1 Ex e and Class I Div. 2 groups ABCD Worldwide certification, UL, cCSAus, IECEx and ATEX
- Product Description - Cable gland
- Product Type - CMP-150TMC
- Title Product Variant Technical Data - CMP-150TMC gland NB NPT1 1/2"
- WebCode - TMCA
Mechanical Data
- Armouring type - TECK-armoured cables
- Clamping range - 33.50 - 41.10 mm
- Clamping range max. - 41.10 mm
- Clamping range min. - 33.50 mm
- Construction type - BS 6121, IEC/EN 62444
- Degree of protection (IP) - IP66
- Degree of protection note - Mounting in accordance with the specifications of the manufacturer, CMP
- Inner sheath - 33.50 … 41.10 mm
- Lot size - 1
- Material - Nickel-plated brass
- Outer sheath - 35.60 … 44.10 mm
- Protrusion length - 58.60 mm
- PVC-shroud - PVC18
- Sealing material - SOLO LSF
- Thread length - 26.100 mm
- Thread pitch - 11,5 TPI
- Thread size - NPT1-1/2
- Thread standard - NPT
- Weight - 0.690 kg
- Width across corners - 66.00 mm
- Width across flats - 60.00 mm
1 - 12 of 17 Part Numbers