Brand: Burkert Fluid Control SystemsType 6164 was developed with the goal, to simplify pneumatic control with optimum integration of a pilot valve in block and plastic moulding parts. Thus, making a more compact design possible.
This valve sets new standards with its uncompromising reliability, above average life cycle span and excellent fluidic characteristics.
Various certifications and conformities make the use of the valve in medical applications such as media multiplexers in dental technology and oxygen control in respirators possible.
Features- Compact design with 11 mm width per station
- High durability and reliability
- Low power consumption, as well as optional ATEX Ex ib version
- Design for optimum integration
1 - 11 of 11 Part Numbers
272 893
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 9.5 (L/min)
- Pressure Range - -9 bar
- Voltage - 24 Vdc
- Power Rating - 0.7 W
272 894
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 1.2 / 1.1
- 1-2 QNn Value Air / 2-3 QNn Value Air - 25 (L/min) / 22 (L/min)
- Pressure Range - -1.5 bar
- Voltage - 24 Vdc
- Power Rating - 2.8 W / 0.3-W
273 612
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 9.5 (L/min)
- Pressure Range - -9 bar
- Voltage - 12 Vdc
- Power Rating - 0.7 W
273 614
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Open
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.65 / 0.5
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6.5 (L/min) / 6 (L/min)
- Pressure Range - -6 bar
- Voltage - 24 Vdc
- Power Rating - 0.7 W
273 615
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Open
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.65 / 0.5
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6.5 (L/min) / 6 (L/min)
- Pressure Range - -6 bar
- Voltage - 12 Vdc
- Power Rating - 0.7 W
281 022
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 9.5 (L/min)
- Pressure Range - 2.5-10 bar
- Voltage - 24 Vdc
- Power Rating - 0.7 W
285 700
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 1.0 / 1.1
- 1-2 QNn Value Air / 2-3 QNn Value Air - 20 (L/min) / 20 (L/min)
- Pressure Range - -5 bar
- Voltage - 24 Vdc
- Power Rating - 2.8 W / 0.3-W
285 701
- Version - Standard Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.8 / 1.1
- 1-2 QNn Value Air / 2-3 QNn Value Air - 16 (L/min) / 20 (L/min)
- Pressure Range - -7.5 bar
- Voltage - 24 Vdc
- Power Rating - 2.8 W / 0.3-W
289 027
- Version - Ex Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 9.5 (L/min)
- Pressure Range - -6 bar
- Resistance - 320 Ohms
- Minimum Holding Current - 29 mA
289 028
- Version - Ex Version
- Circuit Function - 3/2-Way Valve, Direct Mounting, Normally Closed
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 9.5 (L/min)
- Pressure Range - -6 bar
- Resistance - 510 Ohms
- Minimum Holding Current - 23 mA
292 608
- Version - Standard Version
- Circuit Function - 3/2-Way Valve Universal Function
- 1-2 Orifice Ventilation / 2-3 Orifice Ventilation - 0.5 / 0.65
- 1-2 QNn Value Air / 2-3 QNn Value Air - 6 (L/min) / 6 (L/min)
- Pressure Range - -4 bar
- Voltage - 24 Vdc
- Power Rating - 0.7 W
1 - 11 of 11 Part Numbers
Specifications
Ambient Temperature Range
- FKM: -10° to 55° C (14° to 131° F)
- Low Temperature Version: -20° to 55° C (-4° to 131° F)
Approvals & Certifications
- BVS 16-ATEX-E 088 X: II 2 G Ex Ib IIC T6-T4 Gb, II 2D Ex Ib IIIB T1 55° C Db
- IECx PTB 07.0063
- UL Class 2
Consumption
- Power: 0.3 W - Exi Version
- Power: 0.7 W
- Power: 2.8 W / 0.3 W - with External Electric Power Reduction
Current
- Holding Current: 23-29 mA Min.
Duty Cycle
- 100 % Duty Cycle Continious Rating
Electrical Connectors
- Flying Leads
- Plug Connection
- Soldering Connection
Electrical Contacts
- Normally Closed
- Normally Open
Enclosure, Body Material
- Coil: AISI 434 Stainless Steel (1.4113)
- PEEK
Environmental Protection
- Leads: IP54
- Pins: IP00
- Special Plug: IP40
Frequency
- Switching Noise: 42 dB - According to ISO 3745, Testing Environment in Brass Manifold, Free-Hanging
- Switching: 16 Hz
Materials of Construction
- Core: AISI 434 Stainless Steel (1.4113)
- Fitting: Brass
- Seal Switch: Polyamide
Media
- Neutral Gases
O-Ring Material
- FKM
Operating Voltages
- 12 Vdc
- 24 Vdc
Orifice Size
- 0.01” to 0.04” (0.5 to 1.2 mm)
Pressure Drop
- Permissible Leakage (Vacuum): psi: -145 (kPa: -1,000, bar: -10)
Pressure Range
- Vacuum - psi: -130.5 to -21.7 (kPa: -900 to -150, bar: -9 to -1.5)
Process Temperature
- FKM: -10° to 55° C (14° to 131° F)
- Low Temperature Version: -20° to 55° C (-4° to 131° F)
Resistance
- Nominal Coil: 320 to 510 ohms ± 4 %
Response Time
- Open, Close (Pressure Rise 0-10 %, 100-90 %): < 5 milliseconds
Seat / Seal Material
- Seal: FKM
Solenoid Type
- 3/2-Way
Spring Material
- AISI 301 Stainless Steel 1.4310
Tolerance
- Volatge: ± 10 %
- Medical applications