Brand: R. STAHL AG

9147 series vibration transducer power supply units connect vibration, acceleration and speed sensors to analysis systems. 

The measuring signals are galvanically separated when they are transmitted. 

They are transmitted at frequencies of up to 50 Hz. 

These units have already been tested with numerous sensors from well-known manufacturers and are in use in systems across the globe.
Features
  • Space-saving two-channel variant reduces installation costs
  • easily accessible rotary switch makes adjustment simple
  • can be used up to SIL 2 (IEC 61508)

1 - 4 of 4 Part Numbers
212432
212432
R. STAHL Vibration Transducer Supply Device Ex I Field Circuit ISpac
Space-saving two-channel variant reduces installation costs

easily accessible rotary switch makes adjustment simple

can be used up to SIL 2 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +70 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +70 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - 24 V DC
  • Auxiliary power voltage range - 18 ... 31,2 V
  • Nominal current - 75.00 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption - 1.80 W
  • Power dissipation max. - 1.40 W
  • Undervoltage monitoring - yes (no faulty devices / output states)
  • Voltage range residual ripple - ≤ 3,6 VSS

Electrical Data

  • Error limits DC transmission fault - < 0.5 % (at Un and 20 °C)
  • Error limits load resistance influence - < 0.35 % / kOhm (at RL = 3 … 10 kΩ)
  • Error limits Note - relative to the measuring span -20 … -0,5 V
  • Number of channels - 1
  • Operation indication - LED green "PWR"
  • Output current for 2-wire operation - 2,6 / 4,3 / 7,9 mA at -10 V
  • Output current for 3-wire operation - 10 mA at -20 V; 20 mA at -17 V
  • Signal transmission ripple at a load resistance fo 10 kOhm - < 60 mV SS at a bandwidth of 20 MHz

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 12 ATEX E 007 X
  • ATEX firedamp certificate - BVS 12 ATEX E 007 X
  • ATEX gas certificate - BVS 12 ATEX E 007 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), SIL (exida), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Firedamp protection ATEX - I (M1) [Ex ia Ma] I
  • Firedamp protection IECEx - [Ex ia Ma] I
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 12.0001 X
  • IECEx firedamp certificate - IECEx BVS 12.0001 X
  • IECEX gas certificate - IECEx BVS 12.0001 X
  • Installation - in Zone 2
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9147 series vibration transducer power supply units connect vibration, acceleration and speed sensors to analysis systems. The measuring signals are galvanically separated when they are transmitted. They are transmitted at frequencies of up to 50 Hz. These units have already been tested with numerous sensors from well-known manufacturers and are in use in systems across the globe.
  • Highlights - Space-saving two-channel variant reduces installation costs easily accessible rotary switch makes adjustment simple can be used up to SIL 2 (IEC 61508)
  • Product Description - Vibration transducer Supply device Ex i field circuit ISpac
  • Product Type - 9147/10-99-10s
  • Product Variant - Vibration Transducer Supply Unit
  • WebCode - 9147A

Input

  • Input - -20 - -0.5 V
  • Input functional range - -24 - 0 V
  • Input resistance - 10 kΩs
  • input signal - -20 ... -0.5 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.150 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - vertical horizontal
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • Auxiliary power influence error limits - < 0,05 %
  • Internal resistance R i note - < 30,00 Ω
  • LFD relay - No
  • Load resistance R L - > 2 kΩ
  • Load resistance R L max. note - > 2000 ohms
  • Output - -20 ... -0.5 V
  • output signal - -20 to -0.5 V
  • Response time output - < 7 µs
  • Signal transmission delay - < 7 μs
  • Signal transmission freq range - 0 - 50 kHz
  • Signal transmission phase fluctuation - < 0.6% / period
  • Temperature influence error limits - < 0.05% / 10 K

Safety Data

  • Internal capacitance C i - 2.4 nF
  • Internal inductance L i - negligible
  • Max. Current I o - 88.3 mA
  • Max. permissible external capacitance C o for I - 3.950 μF
  • Max. permissible external capacitance C o for IIA - 2.510 μF
  • Max. permissible external capacitance C o for IIB - 0.740 μF
  • Max. permissible external capacitance C o for IIC - 0.097 μF
  • Max. permissible external inductance L o for I - 40.00 mH
  • Max. permissible external inductance L o for IIA - 28.00 mH
  • Max. permissible external inductance L o for IIB - 17.000 mH
  • Max. permissible external inductance L o for IIC - 2.200 mH
  • Max. Power P o - 579.000 mW
  • Max. Voltage U o - 26.30 V
  • Safety-related maximum voltage - 253 V
212433
212433
R. STAHL Vibration Transducer Supply Device Ex I Field Circuit ISpac
Space-saving two-channel variant reduces installation costs

easily accessible rotary switch makes adjustment simple

can be used up to SIL 2 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +70 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +70 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - 24 V DC
  • Auxiliary power voltage range - 18 ... 31,2 V
  • Nominal current - 88.00 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption - 2.10 W
  • Power dissipation max. - 1.80 W
  • Undervoltage monitoring - yes (no faulty devices / output states)
  • Voltage range residual ripple - ≤ 3,6 VSS

Electrical Data

  • Error limits DC transmission fault - < 0.5 % (at Un and 20 °C)
  • Error limits load resistance influence - < 0.35 % / kOhm (at RL = 3 … 10 kΩ)
  • Error limits Note - relative to the measuring span -20 … -0,5 V
  • Number of channels - 2
  • Operation indication - LED green "PWR"
  • Output current for 2-wire operation - 2,6 / 4,3 / 7,9 mA at -10 V
  • Output current for 3-wire operation - 10 mA at -20 V; 20 mA at -17 V
  • Signal transmission ripple at a load resistance fo 10 kOhm - < 60 mV SS at a bandwidth of 20 MHz

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 12 ATEX E 007 X
  • ATEX firedamp certificate - BVS 12 ATEX E 007 X
  • ATEX gas certificate - BVS 12 ATEX E 007 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), SIL (exida), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Firedamp protection ATEX - I (M1) [Ex ia Ma] I
  • Firedamp protection IECEx - [Ex ia Ma] I
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 12.0001 X
  • IECEx firedamp certificate - IECEx BVS 12.0001 X
  • IECEX gas certificate - IECEx BVS 12.0001 X
  • Installation - in Zone 2
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9147 series vibration transducer power supply units connect vibration, acceleration and speed sensors to analysis systems. The measuring signals are galvanically separated when they are transmitted. They are transmitted at frequencies of up to 50 Hz. These units have already been tested with numerous sensors from well-known manufacturers and are in use in systems across the globe.
  • Highlights - Space-saving two-channel variant reduces installation costs easily accessible rotary switch makes adjustment simple can be used up to SIL 2 (IEC 61508)
  • Product Description - Vibration transducer Supply device Ex i field circuit ISpac
  • Product Type - 9147/20-99-10s
  • Product Variant - Vibration Transducer Supply Unit
  • WebCode - 9147A

Input

  • Input - -20 - -0.5 V
  • Input functional range - -24 - 0 V
  • Input resistance - 10 kΩs
  • input signal - -20 ... -0.5 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.210 kg

Mounting / Installation

  • Connection type - Screw terminal
  • Mounting position - horizontal vertical
  • Mounting type - DIN rail (NS35/15, NS35/7.5)

Output

  • Auxiliary power influence error limits - < 0,05 %
  • Internal resistance R i note - < 30,00 Ω
  • LFD relay - No
  • Load resistance R L - > 10 kΩ
  • Load resistance R L max. note - > 10,000 ohms
  • Output - -20 ... -0.5 V
  • output signal - -20 to -0.5 V
  • Response time output - < 7 µs
  • Signal transmission delay - < 7 μs
  • Signal transmission freq range - 0 - 50 kHz
  • Signal transmission phase fluctuation - < 0.6% / period
  • Temperature influence error limits - < 0.05% / 10 K

Safety Data

  • Internal capacitance C i - 2.4 nF
  • Internal inductance L i - negligible
  • Max. Current I o - 88.3 mA
  • Max. permissible external capacitance C o for I - 3.950 μF
  • Max. permissible external capacitance C o for IIA - 2.510 μF
  • Max. permissible external capacitance C o for IIB - 0.740 μF
  • Max. permissible external capacitance C o for IIC - 0.097 μF
  • Max. permissible external inductance L o for I - 40.00 mH
  • Max. permissible external inductance L o for IIA - 28.00 mH
  • Max. permissible external inductance L o for IIB - 17.000 mH
  • Max. permissible external inductance L o for IIC - 2.200 mH
  • Max. Power P o - 579.000 mW
  • Max. Voltage U o - 26.30 V
  • Safety-related maximum voltage - 253 V
213112
213112
R. STAHL Vibration Transducer Supply Device Ex I Field Circuit ISpac
Space-saving two-channel variant reduces installation costs

easily accessible rotary switch makes adjustment simple

can be used up to SIL 2 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +70 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +70 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - 24 V DC
  • Auxiliary power voltage range - 18 ... 31,2 V
  • Nominal current - 75.00 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption - 1.80 W
  • Power dissipation max. - 1.40 W
  • Undervoltage monitoring - yes (no faulty devices / output states)
  • Voltage range residual ripple - ≤ 3,6 VSS

Electrical Data

  • Error limits DC transmission fault - < 0.5 % (at Un and 20 °C)
  • Error limits load resistance influence - < 0.35 % / kOhm (at RL = 3 … 10 kΩ)
  • Error limits Note - relative to the measuring span -20 … -0,5 V
  • Number of channels - 1
  • Operation indication - LED green "PWR"
  • Output current for 2-wire operation - 2,6 / 4,3 / 7,9 mA at -10 V
  • Output current for 3-wire operation - 10 mA at -20 V; 20 mA at -17 V
  • Signal transmission ripple at a load resistance fo 10 kOhm - < 60 mV SS at a bandwidth of 20 MHz

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 12 ATEX E 007 X
  • ATEX firedamp certificate - BVS 12 ATEX E 007 X
  • ATEX gas certificate - BVS 12 ATEX E 007 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), SIL (exida), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Firedamp protection ATEX - I (M1) [Ex ia Ma] I
  • Firedamp protection IECEx - [Ex ia Ma] I
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 12.0001 X
  • IECEx firedamp certificate - IECEx BVS 12.0001 X
  • IECEX gas certificate - IECEx BVS 12.0001 X
  • Installation - in Zone 2
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9147 series vibration transducer power supply units connect vibration, acceleration and speed sensors to analysis systems. The measuring signals are galvanically separated when they are transmitted. They are transmitted at frequencies of up to 50 Hz. These units have already been tested with numerous sensors from well-known manufacturers and are in use in systems across the globe.
  • Highlights - Space-saving two-channel variant reduces installation costs easily accessible rotary switch makes adjustment simple can be used up to SIL 2 (IEC 61508)
  • Product Description - Vibration transducer Supply device Ex i field circuit ISpac
  • Product Type - 9147/10-99-10k
  • Product Variant - Vibration Transducer Supply Unit
  • Title Product Variant Technical Data - 9147/10-99-10k Vibration TSU
  • WebCode - 9147A

Input

  • Input - -20 - -0.5 V
  • Input functional range - -24 - 0 V
  • Input resistance - 10 kΩs
  • input signal - -20 ... -0.5 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.150 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - Rail (NS35/15, NS35/7.5)

Output

  • Auxiliary power influence error limits - < 0,05 %
  • Internal resistance R i note - < 30,00 Ω
  • LFD relay - No
  • Load resistance R L - > 2 kΩ
  • Load resistance R L max. note - > 2000 ohms
  • Output - -20 ... -0.5 V
  • output signal - -20 to -0.5 V
  • Response time output - < 7 µs
  • Signal transmission delay - < 7 μs
  • Signal transmission freq range - 0 - 50 kHz
  • Signal transmission phase fluctuation - < 0.6% / period
  • Temperature influence error limits - < 0.05% / 10 K

Safety Data

  • Internal capacitance C i - 2.4 nF
  • Internal inductance L i - negligible
  • Max. Current I o - 88.3 mA
  • Max. permissible external capacitance C o for I - 3.950 μF
  • Max. permissible external capacitance C o for IIA - 2.510 μF
  • Max. permissible external capacitance C o for IIB - 0.740 μF
  • Max. permissible external capacitance C o for IIC - 0.097 μF
  • Max. permissible external inductance L o for I - 40.00 mH
  • Max. permissible external inductance L o for IIA - 28.00 mH
  • Max. permissible external inductance L o for IIB - 17.000 mH
  • Max. permissible external inductance L o for IIC - 2.200 mH
  • Max. Power P o - 579.000 mW
  • Max. Voltage U o - 26.30 V
  • Safety-related maximum voltage - 253 V
213113
213113
R. STAHL Vibration Transducer Supply Device Ex I Field Circuit ISpac
Space-saving two-channel variant reduces installation costs

easily accessible rotary switch makes adjustment simple

can be used up to SIL 2 (IEC 61508)

Ambient Conditions

  • Ambient temperature - -20 °C ... +70 °C (Single device) -20 °C ... +70 °C (Group assembly)
  • Ambient temperature max. - +70 °C
  • Ambient temperature max. note - Single device
  • Ambient temperature max. note 2 - Group assembly
  • Ambient temperature max.2 - +70 °C
  • Ambient temperature min. - -20 °C
  • Ambient temperature min. 2 - -20 °C
  • Ambient temperature min. note - Single device
  • Ambient temperature min. note 2 - Group assembly
  • Electromagnetic compatibility - Tested to the following standards and regulations: EN 61326-1 Use in industrial environment
  • Relative humidity max. - 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - 24 V DC
  • Auxiliary power voltage range - 18 ... 31,2 V
  • Nominal current - 88.00 mA
  • Nominal voltage - 24 V DC
  • Polarity reversal protection - yes
  • Power consumption - 2.10 W
  • Power dissipation max. - 1.80 W
  • Undervoltage monitoring - yes (no faulty devices / output states)
  • Voltage range residual ripple - ≤ 3,6 VSS

Electrical Data

  • Error limits DC transmission fault - < 0.5 % (at Un and 20 °C)
  • Error limits load resistance influence - < 0.35 % / kOhm (at RL = 3 … 10 kΩ)
  • Error limits Note - relative to the measuring span -20 … -0,5 V
  • Number of channels - 2
  • Operation indication - LED green "PWR"
  • Output current for 2-wire operation - 2,6 / 4,3 / 7,9 mA at -10 V
  • Output current for 3-wire operation - 10 mA at -20 V; 20 mA at -17 V
  • Signal transmission ripple at a load resistance fo 10 kOhm - < 60 mV SS at a bandwidth of 20 MHz

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - BVS 12 ATEX E 007 X
  • ATEX firedamp certificate - BVS 12 ATEX E 007 X
  • ATEX gas certificate - BVS 12 ATEX E 007 X
  • Certificate EAC - TS RU S-DE.GB04.B.00353
  • Certificates - ATEX (BVS), Canada (FM), EAC (STV), IECEx (BVS), India (PESO), SIL (exida), USA (FM)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection EAC - [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Firedamp protection ATEX - I (M1) [Ex ia Ma] I
  • Firedamp protection IECEx - [Ex ia Ma] I
  • Further information - see respective certificate and operating instructions
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx BVS 12.0001 X
  • IECEx firedamp certificate - IECEx BVS 12.0001 X
  • IECEX gas certificate - IECEx BVS 12.0001 X
  • Installation - in Zone 2
  • Installation in Division NEC 500 - (Class I, II, III) 2
  • Ship approval - CCS, DNVGL

General

  • Functional Description - 9147 series vibration transducer power supply units connect vibration, acceleration and speed sensors to analysis systems. The measuring signals are galvanically separated when they are transmitted. They are transmitted at frequencies of up to 50 Hz. These units have already been tested with numerous sensors from well-known manufacturers and are in use in systems across the globe.
  • Highlights - Space-saving two-channel variant reduces installation costs easily accessible rotary switch makes adjustment simple can be used up to SIL 2 (IEC 61508)
  • Product Description - Vibration transducer Supply device Ex i field circuit ISpac
  • Product Type - 9147/20-99-10k
  • Product Variant - Vibration Transducer Supply Unit
  • Title Product Variant Technical Data - 9147/20-99-10k Vibration TSU
  • WebCode - 9147A

Input

  • Input - -20 - -0.5 V
  • Input functional range - -24 - 0 V
  • Input resistance - 10 kΩs
  • input signal - -20 ... -0.5 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 17.60 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.150 kg

Mounting / Installation

  • Connection type - Spring clamp terminal
  • Mounting position - horizontal vertical
  • Mounting type - Rail (NS35/15, NS35/7.5)

Output

  • Auxiliary power influence error limits - < 0,05 %
  • Internal resistance R i note - < 30,00 Ω
  • LFD relay - No
  • Load resistance R L - > 10 kΩ
  • Load resistance R L max. note - > 10,000 ohms
  • Output - -20 ... -0.5 V
  • output signal - -20 to -0.5 V
  • Response time output - < 7 µs
  • Signal transmission delay - < 7 μs
  • Signal transmission freq range - 0 - 50 kHz
  • Signal transmission phase fluctuation - < 0.6% / period
  • Temperature influence error limits - < 0.05% / 10 K

Safety Data

  • Internal capacitance C i - 2.4 nF
  • Internal inductance L i - negligible
  • Max. Current I o - 88.3 mA
  • Max. permissible external capacitance C o for I - 3.950 μF
  • Max. permissible external capacitance C o for IIA - 2.510 μF
  • Max. permissible external capacitance C o for IIB - 0.740 μF
  • Max. permissible external capacitance C o for IIC - 0.097 μF
  • Max. permissible external inductance L o for I - 40.00 mH
  • Max. permissible external inductance L o for IIA - 28.00 mH
  • Max. permissible external inductance L o for IIB - 17.000 mH
  • Max. permissible external inductance L o for IIC - 2.200 mH
  • Max. Power P o - 579.000 mW
  • Max. Voltage U o - 26.30 V
  • Safety-related maximum voltage - 253 V