Yodify Product Library
Instantly add the RMLD Complete Solution (RMLD-CS™) and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

RMLD Complete Solution (RMLD-CS™)

Brand: Heath Consultants Incorporated

Heath’s RMLD technologies have led the industry for remote methane detection since the release of the original unit in 2005. 

Our newest model the RMLD Complete Solution (RMLD-CS) utilizes the same TDLAS technology but in a more convenient, lightweight, single unit package without compromising performance. 

The RMLD-CS is field rugged and operates under a variety of field conditions including a wide temperature range, light rain and fog.

The RMLD-CS is Intrinsically Safety (IS) with a rating of Class I, Division II, which allows operators to use it indoors and within potentially hazardous environments such as compressor stations. 

With detection up to 100 feet away operators can safely survey in areas that may be difficult to reach such as busy roadways, yards with dogs, fenced off areas, compressor stations, overhead piping and other hard to access places.
Features
  • Intrinsically safe
  • Rechargeable/replaceable battery
  • Dual battery charger
  • Mobile App support
  • Ergonomic housing
  • Lightweight
  • Graphical user interface
  • Internal data logging
  • WiFi
  • GPS
  • Bluetooth BLE
  • Color camera and display

1 - 9 of 9 Part Numbers
105301
105301
Complete Kit Assembly
Includes
  • RMLD-CS Instrument(with battery pack)
  • Battery Pack Charger
  • Test Gas Cell
  • USB Cable
  • Carry Strap
  • Carry Case
105354
105354
RMLD-CS Instrument
  • Methane gas detection up to 100’ away
  • User interface
  • Data logging interface
  • Battery Pack
  • Power connector
105358
105358
Battery Pack Charger
  • Universal 100 - 240 VAC, 506-60 Hz
  • Two (2) slots for dual battery pack charging
  • Recharge the instrument’s battery pack after use
  •  LED on the front indicates charging status
  • Use only with HPN 105727 Battery Pack
105359
105359
Universal Power Supply (AC Adapter) and AC Power Cord (US/Canada)
105473
105473
USB Cable
  • USB2 A to USB micro cable
  • Download data from the instrument to a computer
  • Serial communication
105528
105528
AC Power Cord (US/Canada Only)
105530
105530
Carrying Case
  • Protects the instrument during storage and transport
  • Built-in test gas cell for self-test
  • Keep instrument in the case while not in use
105727
105727
Battery Pack
  • Rechargeable Li-Ion battery pack
  • Provides power to the instrument
  • Charges independently of the instrument
  • Up to eight (8) hours of operating time on a full charge
  • Recharge between uses to assure no interruption in use
  • Use only with HPN 105358 Battery Pack Charger
106024
106024
Test Gas Cell
1 - 9 of 9 Part Numbers

Specifications

Weight

  • 3 lbs (approx.)

Carry Case Dimensions

  • 21” x 17.5” x 9.5”

Display

  • 3.5” color LCD, 320 x 240 resolution

Battery

  • Removable
  • Rechargeable
  • Lithium-ion pack, 10.8 Vdc at 3.2Ah

Battery Run Time

  • 8 hours at 32° F (approx.)

Battery Charger

  • External, 110-240 Vac, 50/60 Hz Universal

Charge Time

  • 2-3 hours full charge (approx.)

Detection Method

  • Tunable Diode Laser Absorption Spectroscopy (TDLAS)

Detection Distance

  • 100 ft (30 m) nominal - may vary due to background type and conditions

Measurement Range

  • 0 to 50K ppm-M

Sensitivity

  • 5 ppm-M at distances from 0 to 100 ft (30 m)

Beam Size

  • Conical in shape with a 22” diameter at100 ft (55 cm at 30 m)

IR Laser

  • Class I

Green Spotter

  • Class 2(II) < 5 mW @ 510-530 nm
  • Spot size is 7 mm at 15M
  • Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007

Color Camera: Aperture

  • f/2.6

Color Camera: FOV

  • 94DEG (at 6.0 mm image circle)

GNSS Compatibility

  • GPS
  • GLONASS
  • Beidou
  • Galilieo

Communication

  • USB Dual Mode - flash drive and communications
  • USB Port Max. Rating: Um = 5 V, In = 5 A Bluetooth 4.2 BLE
  • WiFi b/g

Digital Methane Detection (DMD)

  • Audible tone and visual alerts when detection threshold exceeded

Adjustable Detection Alarm Level

  • 1 to 999 ppm-M

Alarm Response Time

  • Typically 0.1 - 0.2 seconds

Real Time (RT)

  • Continuous beep rate relative to concentration from 10-1000 ppm-M

System Fault & Warnings

  • Audible alarm and visual indication on the display

Built-In Self-Test

  • Verifies operation and adjusts laser wavelength for maximum sensitivity

Test Gas Cell

  • Integrated within carrying case

Operating Temperature

  • 0° to +122° F (-17° to 50° C)

Humidity

  • 5 to 95 % RH, non-condensing

Altitude

  • Up to 2000 M

Environment of Use

  • Pollution Degree 2 or better. Outdoor use

Ingress Protection

  • IP54 (water splash and dust resistant)

Compliance

  • EMC (EN 61000-6-2, EN 6100-6-4)

Low Voltage Directive

  • (2014/35/EU)

Radio Equipment Directive

  • (2014/53/EU)

Regulatory

  • ETSI EN 301 489-1 v2.2.0
  • EN 61326-1:2013
  • 47 CFR Part 15 & ICES-003

Ordinary Location Safety

  • UL 61010-1
  • CAN/CSA C22.2 No 61010-1-12

Hazardous Location Safety

  • Class I, Zone 2, AEx ic op is IIA T4 Gc
  • Class I, Div. 2, Group D Intrinsically Safe

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team