Brand: R. STAHL AGSeries 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit.
The intrinsically safe outputs are galvanically separated from the inputs.
Features- A comprehensive portfolio for a wide range of solenoid valves
- Space savings due to a slim design – 12.5 mm wide
- Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
1 - 4 of 4 Part Numbers

261440
A comprehensive portfolio for a wide range of solenoid valves
Space savings due to a slim design – 12.5 mm wide
Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
- Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
- Relative humidity max. - 10 to 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Polarity reversal protection - yes
- Power dissipation max. - 0.85 W
- Undervoltage monitoring - No
Electrical Data
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - IBExU 17 ATEX 1153 X
- ATEX gas certificate - IBExU 17 ATEX 1153 X
- Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx IBE 17.0045X
- IECEX gas certificate - IECEx IBE 17.0045X
- Installation in Division NEC 500 - (Class I, II, III) 2
Galvanic isolation
- Galvanic isolation Ex i output to input - 375 V AC peak value
- Test voltage according to standard - IEC EN 60079-11
General
- Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
- Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
- Product Description - Digital output loop powered Ex i field circuit
- Product Type - 9276/10-21-25-00s
- Title Product Variant Technical Data - 9276/10-21-25-00s, 9276/10-21-40-00s, 9276/10-24-48-00s
- WebCode - 9276A
Input
- Input voltage for OFF - 0 - 5 V
- Input voltage for ON - 15.0 - 30.0 V
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 12.50 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.165 kg
Mounting / Installation
- Conduct cross-section flexible max. - 2.5 mm²
- Conduct cross-section flexible max. - 0.2 mm²
- Conductor cross-section solid max. - 2.5 mm²
- Conductor cross-section solid min. - 0.2 mm²
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Max. output current I a max - 25.00 mA
- Output internal resistiance R i - 641.10 Ω
- Output open circuit voltage U a - 21,9 V
- Response time output - 20 ms
- Switching delay ON/OFF - ≤ 20 ms
- Switching state indication - Yellow LED "STAT"
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. current I o (Ex ia) - 39.00 mA
- Max. permissible external capacitance C o for IIA - 2.930 μF
- Max. permissible external capacitance C o for IIB - 0.830 μF
- Max. permissible external capacitance C o for IIC - 0.108 μF
- Max. permissible external inductance L o for IIA - 170.00 mH
- Max. permissible external inductance L o for IIB - 90.000 mH
- Max. permissible external inductance L o for IIC - 22.000 mH
- Max. Power P o - 245.000 mW
- Max. Voltage U o - 25.10 V
- Safety-related maximum voltage - 253 V AC

261441
A comprehensive portfolio for a wide range of solenoid valves
Space savings due to a slim design – 12.5 mm wide
Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
- Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
- Relative humidity max. - 10 to 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Polarity reversal protection - yes
- Power dissipation max. - 1.06 W
- Undervoltage monitoring - No
Electrical Data
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - IBExU 17 ATEX 1153 X
- ATEX gas certificate - IBExU 17 ATEX 1153 X
- Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx IBE 17.0045X
- IECEX gas certificate - IECEx IBE 17.0045X
- Installation in Division NEC 500 - (Class I, II, III) 2
Galvanic isolation
- Galvanic isolation Ex i output to input - 375 V AC peak value
- Test voltage according to standard - IEC EN 60079-11
General
- Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
- Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
- Product Description - Digital output loop powered Ex i field circuit
- Product Type - 9276/10-21-40-00s
- Title Product Variant Technical Data - 9276/10-21-40-00s digital output lp
- WebCode - 9276A
Input
- Input voltage for OFF - 0 - 5 V
- Input voltage for ON - 15.0 - 30.0 V
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 12.50 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.165 kg
Mounting / Installation
- Conduct cross-section flexible max. - 0.2 mm²
- Conduct cross-section flexible max. - 2.5 mm²
- Conductor cross-section solid max. - 2.5 mm²
- Conductor cross-section solid min. - 0.2 mm²
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Max. output current I a max - 40.00 mA
- Output internal resistiance R i - 287.00 Ω
- Output open circuit voltage U a - 21,9 V
- Response time output - 20 ms
- Switching delay ON/OFF - ≤ 20 ms
- Switching state indication - Yellow LED "STAT"
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. current I o (Ex ia) - 87.00 mA
- Max. permissible external capacitance C o for IIA - 2.930 μF
- Max. permissible external capacitance C o for IIB - 0.830 μF
- Max. permissible external capacitance C o for IIC - 0.108 μF
- Max. permissible external inductance L o for IIA - 45.00 mH
- Max. permissible external inductance L o for IIB - 20.000 mH
- Max. permissible external inductance L o for IIC - 5.000 mH
- Max. Power P o - 550.000 mW
- Max. Voltage U o - 25.10 V
- Safety-related maximum voltage - 253 V AC

261442
A comprehensive portfolio for a wide range of solenoid valves
Space savings due to a slim design – 12.5 mm wide
Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
- Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
- Relative humidity max. - 10 to 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Polarity reversal protection - yes
- Power dissipation max. - 1.41 W
- Undervoltage monitoring - No
Electrical Data
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - IBExU 17 ATEX 1153 X
- ATEX gas certificate - IBExU 17 ATEX 1153 X
- Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
- IECEX dust certificate - IECEx IBE 17.0045X
- IECEX gas certificate - IECEx IBE 17.0045X
- Installation in Division NEC 500 - (Class I, II, III) 2
Galvanic isolation
- Galvanic isolation Ex i output to input - 375 V AC peak value
- Test voltage according to standard - IEC EN 60079-11
General
- Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
- Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
- Product Description - Digital output loop powered Ex i field circuit
- Product Type - 9276/10-24-48-00s
- Title Product Variant Technical Data - 9276/10-24-48-00s digital output lp
- WebCode - 9276A
Input
- Input voltage for OFF - 0 - 5 V
- Input voltage for ON - 15.0 - 30.0 V
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 12.50 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.165 kg
Mounting / Installation
- Conduct cross-section flexible max. - 2.5 mm²
- Conduct cross-section flexible max. - 0.2 mm²
- Conductor cross-section solid max. - 2.5 mm²
- Conductor cross-section solid min. - 0.2 mm²
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Max. output current I a max - 48.00 mA
- Output internal resistiance R i - 275.50 Ω
- Output open circuit voltage U a - 24 V
- Response time output - 20 ms
- Switching delay ON/OFF - ≤ 20 ms
- Switching state indication - Yellow LED "STAT"
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. current I o (Ex ia) - 101.00 mA
- Max. permissible external capacitance C o for IIA - 2.200 μF
- Max. permissible external capacitance C o for IIB - 0.663 μF
- Max. permissible external capacitance C o for IIC - 0.085 μF
- Max. permissible external inductance L o for IIA - 35.00 mH
- Max. permissible external inductance L o for IIB - 17.000 mH
- Max. permissible external inductance L o for IIC - 4.000 mH
- Max. Power P o - 697.000 mW
- Max. Voltage U o - 27.70 V
- Safety-related maximum voltage - 253 V AC

261443
A comprehensive portfolio for a wide range of solenoid valves
Space savings due to a slim design – 12.5 mm wide
Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
Ambient Conditions
- Ambient temperature - -40 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -40 °C
- Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
- Relative humidity max. - 10 to 95%
- Storage temperature - -40 °C ... +80 °C
- Storage temperature max. - +80 °C
- Storage temperature min. - -40 °C
- Use at the height of - < 2000 m
Auxiliary power
- Auxiliary power - without
- Polarity reversal protection - yes
- Power dissipation max. - 1.33 W
- Undervoltage monitoring - No
Electrical Data
- Number of channels - 1
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - IBExU 17 ATEX 1153 X
- ATEX gas certificate - IBExU 17 ATEX 1153 X
- Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia IIB Ga] IIC T4 Gc
- Gas explosion protection IECEx - Ex nA [ia IIB Ga] IIC T4 Gc
- IECEX dust certificate - IECEx IBE 17.0045X
- IECEX gas certificate - IECEx IBE 17.0045X
- Installation in Division NEC 500 - (Class I, II, III) 2
Galvanic isolation
- Galvanic isolation Ex i output to input - 375 V AC peak value
- Test voltage according to standard - IEC EN 60079-11
General
- Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
- Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
- Product Description - Digital output loop powered Ex i field circuit
- Product Type - 9276/10-21-60-00s
- Title Product Variant Technical Data - 9276/10-21-60-00s
- WebCode - 9276A
Input
- Input voltage for OFF - 0 - 5 V
- Input voltage for ON - 15.0 - 30.0 V
Mechanical Data
- Degree of protection (IP) - IP30
- Enclosure material - Polyamide
- Fire resistance (UL 94) - V0
- Grid dimension - 12.50 mm
- Terminal degree of protection (IP) - IP20
- Weight - 0.165 kg
Mounting / Installation
- Conduct cross-section flexible max. - 0.2 mm²
- Conduct cross-section flexible max. - 2.5 mm²
- Conductor cross-section solid max. - 2.5 mm²
- Conductor cross-section solid min. - 0.2 mm²
- Connection type - Screw terminal
- Mounting position - vertical horizontal
- Mounting type - NS35/15, NS35/7.5 DIN rail
Output
- LFD relay - No
- Max. output current I a max - 58.00 mA
- Output internal resistiance R i - 133.40 Ω
- Output open circuit voltage U a - 21,9 V
- Response time output - 20 ms
- Switching delay ON/OFF - ≤ 20 ms
- Switching state indication - Yellow LED "STAT"
Safety Data
- Internal capacitance C i - negligible
- Internal inductance L i - negligible
- Max. current I o (Ex ia) - 188.00 mA
- Max. permissible external capacitance C o for IIA - 2.930 μF
- Max. permissible external capacitance C o for IIB - 0.830 μF
- Max. permissible external inductance L o for IIA - 7.50 mH
- Max. permissible external inductance L o for IIB - 4.000 mH
- Max. Power P o - 1180.000 mW
- Max. Voltage U o - 25.10 V
- Safety-related maximum voltage - 253 V AC
1 - 4 of 4 Part Numbers