Yodify Product Library
Instantly add the Digital Output Loop Powered Series 9276 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Digital Output Loop Powered Series 9276

Brand: R. STAHL AG

Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. 

The intrinsically safe outputs are galvanically separated from the inputs.
Features
  • A comprehensive portfolio for a wide range of solenoid valves
  • Space savings due to a slim design – 12.5 mm wide
  • Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)

1 - 4 of 4 Part Numbers
261440
261440
R. STAHL Digital Output Loop Powered Ex I Field Circuit
A comprehensive portfolio for a wide range of solenoid valves

Space savings due to a slim design – 12.5 mm wide

Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)

Ambient Conditions

  • Ambient temperature - -40 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -40 °C
  • Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
  • Relative humidity max. - 10 to 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Polarity reversal protection - yes
  • Power dissipation max. - 0.85 W
  • Undervoltage monitoring - No

Electrical Data

  • Number of channels - 1

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - IBExU 17 ATEX 1153 X
  • ATEX gas certificate - IBExU 17 ATEX 1153 X
  • Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx IBE 17.0045X
  • IECEX gas certificate - IECEx IBE 17.0045X
  • Installation in Division NEC 500 - (Class I, II, III) 2

Galvanic isolation

  • Galvanic isolation Ex i output to input - 375 V AC peak value
  • Test voltage according to standard - IEC EN 60079-11

General

  • Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
  • Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
  • Product Description - Digital output loop powered Ex i field circuit
  • Product Type - 9276/10-21-25-00s
  • Title Product Variant Technical Data - 9276/10-21-25-00s, 9276/10-21-40-00s, 9276/10-24-48-00s
  • WebCode - 9276A

Input

  • Input voltage for OFF - 0 - 5 V
  • Input voltage for ON - 15.0 - 30.0 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 12.50 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.165 kg

Mounting / Installation

  • Conduct cross-section flexible max. - 2.5 mm²
  • Conduct cross-section flexible max. - 0.2 mm²
  • Conductor cross-section solid max. - 2.5 mm²
  • Conductor cross-section solid min. - 0.2 mm²
  • Connection type - Screw terminal
  • Mounting position - vertical horizontal
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Max. output current I a max - 25.00 mA
  • Output internal resistiance R i - 641.10 Ω
  • Output open circuit voltage U a - 21,9 V
  • Response time output - 20 ms
  • Switching delay ON/OFF - ≤ 20 ms
  • Switching state indication - Yellow LED "STAT"

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. current I o (Ex ia) - 39.00 mA
  • Max. permissible external capacitance C o for IIA - 2.930 μF
  • Max. permissible external capacitance C o for IIB - 0.830 μF
  • Max. permissible external capacitance C o for IIC - 0.108 μF
  • Max. permissible external inductance L o for IIA - 170.00 mH
  • Max. permissible external inductance L o for IIB - 90.000 mH
  • Max. permissible external inductance L o for IIC - 22.000 mH
  • Max. Power P o - 245.000 mW
  • Max. Voltage U o - 25.10 V
  • Safety-related maximum voltage - 253 V AC
261441
261441
R. STAHL Digital Output Loop Powered Ex I Field Circuit
A comprehensive portfolio for a wide range of solenoid valves

Space savings due to a slim design – 12.5 mm wide

Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)

Ambient Conditions

  • Ambient temperature - -40 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -40 °C
  • Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
  • Relative humidity max. - 10 to 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Polarity reversal protection - yes
  • Power dissipation max. - 1.06 W
  • Undervoltage monitoring - No

Electrical Data

  • Number of channels - 1

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - IBExU 17 ATEX 1153 X
  • ATEX gas certificate - IBExU 17 ATEX 1153 X
  • Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx IBE 17.0045X
  • IECEX gas certificate - IECEx IBE 17.0045X
  • Installation in Division NEC 500 - (Class I, II, III) 2

Galvanic isolation

  • Galvanic isolation Ex i output to input - 375 V AC peak value
  • Test voltage according to standard - IEC EN 60079-11

General

  • Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
  • Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
  • Product Description - Digital output loop powered Ex i field circuit
  • Product Type - 9276/10-21-40-00s
  • Title Product Variant Technical Data - 9276/10-21-40-00s digital output lp
  • WebCode - 9276A

Input

  • Input voltage for OFF - 0 - 5 V
  • Input voltage for ON - 15.0 - 30.0 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 12.50 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.165 kg

Mounting / Installation

  • Conduct cross-section flexible max. - 0.2 mm²
  • Conduct cross-section flexible max. - 2.5 mm²
  • Conductor cross-section solid max. - 2.5 mm²
  • Conductor cross-section solid min. - 0.2 mm²
  • Connection type - Screw terminal
  • Mounting position - vertical horizontal
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Max. output current I a max - 40.00 mA
  • Output internal resistiance R i - 287.00 Ω
  • Output open circuit voltage U a - 21,9 V
  • Response time output - 20 ms
  • Switching delay ON/OFF - ≤ 20 ms
  • Switching state indication - Yellow LED "STAT"

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. current I o (Ex ia) - 87.00 mA
  • Max. permissible external capacitance C o for IIA - 2.930 μF
  • Max. permissible external capacitance C o for IIB - 0.830 μF
  • Max. permissible external capacitance C o for IIC - 0.108 μF
  • Max. permissible external inductance L o for IIA - 45.00 mH
  • Max. permissible external inductance L o for IIB - 20.000 mH
  • Max. permissible external inductance L o for IIC - 5.000 mH
  • Max. Power P o - 550.000 mW
  • Max. Voltage U o - 25.10 V
  • Safety-related maximum voltage - 253 V AC
261442
261442
R. STAHL Digital Output Loop Powered Ex I Field Circuit
A comprehensive portfolio for a wide range of solenoid valves

Space savings due to a slim design – 12.5 mm wide

Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)

Ambient Conditions

  • Ambient temperature - -40 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -40 °C
  • Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
  • Relative humidity max. - 10 to 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Polarity reversal protection - yes
  • Power dissipation max. - 1.41 W
  • Undervoltage monitoring - No

Electrical Data

  • Number of channels - 1

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - IBExU 17 ATEX 1153 X
  • ATEX gas certificate - IBExU 17 ATEX 1153 X
  • Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA [ia Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx IBE 17.0045X
  • IECEX gas certificate - IECEx IBE 17.0045X
  • Installation in Division NEC 500 - (Class I, II, III) 2

Galvanic isolation

  • Galvanic isolation Ex i output to input - 375 V AC peak value
  • Test voltage according to standard - IEC EN 60079-11

General

  • Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
  • Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
  • Product Description - Digital output loop powered Ex i field circuit
  • Product Type - 9276/10-24-48-00s
  • Title Product Variant Technical Data - 9276/10-24-48-00s digital output lp
  • WebCode - 9276A

Input

  • Input voltage for OFF - 0 - 5 V
  • Input voltage for ON - 15.0 - 30.0 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 12.50 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.165 kg

Mounting / Installation

  • Conduct cross-section flexible max. - 2.5 mm²
  • Conduct cross-section flexible max. - 0.2 mm²
  • Conductor cross-section solid max. - 2.5 mm²
  • Conductor cross-section solid min. - 0.2 mm²
  • Connection type - Screw terminal
  • Mounting position - vertical horizontal
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Max. output current I a max - 48.00 mA
  • Output internal resistiance R i - 275.50 Ω
  • Output open circuit voltage U a - 24 V
  • Response time output - 20 ms
  • Switching delay ON/OFF - ≤ 20 ms
  • Switching state indication - Yellow LED "STAT"

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. current I o (Ex ia) - 101.00 mA
  • Max. permissible external capacitance C o for IIA - 2.200 μF
  • Max. permissible external capacitance C o for IIB - 0.663 μF
  • Max. permissible external capacitance C o for IIC - 0.085 μF
  • Max. permissible external inductance L o for IIA - 35.00 mH
  • Max. permissible external inductance L o for IIB - 17.000 mH
  • Max. permissible external inductance L o for IIC - 4.000 mH
  • Max. Power P o - 697.000 mW
  • Max. Voltage U o - 27.70 V
  • Safety-related maximum voltage - 253 V AC
261443
261443
R. STAHL Digital Output Loop Powered Ex I Field Circuit
A comprehensive portfolio for a wide range of solenoid valves

Space savings due to a slim design – 12.5 mm wide

Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)

Ambient Conditions

  • Ambient temperature - -40 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -40 °C
  • Electromagnetic compatibility - EN 61326-1 Use in industrial environment Immunity according to EN 61000-6-2 Interference emission to EN 61000-6-4
  • Relative humidity max. - 10 to 95%
  • Storage temperature - -40 °C ... +80 °C
  • Storage temperature max. - +80 °C
  • Storage temperature min. - -40 °C
  • Use at the height of - < 2000 m

Auxiliary power

  • Auxiliary power - without
  • Polarity reversal protection - yes
  • Power dissipation max. - 1.33 W
  • Undervoltage monitoring - No

Electrical Data

  • Number of channels - 1

Explosion Protection

  • Application range (zones) - 2, 22
  • ATEX dust certificate - IBExU 17 ATEX 1153 X
  • ATEX gas certificate - IBExU 17 ATEX 1153 X
  • Certificates - ATEX (IBE), Canada / USA (UL), IECEx (IBE), SIL (exida)
  • Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
  • Dust explosion protection IECEx - [Ex ia Da] IIIC
  • Ex interface in Division NEC 500 - (Class I, II, III) 1, 2
  • Ex interface zone - 0, 1, 2, 20, 21, 22
  • Gas explosion protection ATEX - II 3 (1) G Ex nA [ia IIB Ga] IIC T4 Gc
  • Gas explosion protection IECEx - Ex nA [ia IIB Ga] IIC T4 Gc
  • IECEX dust certificate - IECEx IBE 17.0045X
  • IECEX gas certificate - IECEx IBE 17.0045X
  • Installation in Division NEC 500 - (Class I, II, III) 2

Galvanic isolation

  • Galvanic isolation Ex i output to input - 375 V AC peak value
  • Test voltage according to standard - IEC EN 60079-11

General

  • Functional Description - Series 9276 digital outputs issue signals for the intrinsically safe operation of Ex i solenoid valves, indicator lamps or horns. The devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are galvanically separated from the inputs.
  • Highlights - A comprehensive portfolio for a wide range of solenoid valves Space savings due to a slim design – 12.5 mm wide Can be used for functional safety levels up to SIL 3 (IEC/EN 61508)
  • Product Description - Digital output loop powered Ex i field circuit
  • Product Type - 9276/10-21-60-00s
  • Title Product Variant Technical Data - 9276/10-21-60-00s
  • WebCode - 9276A

Input

  • Input voltage for OFF - 0 - 5 V
  • Input voltage for ON - 15.0 - 30.0 V

Mechanical Data

  • Degree of protection (IP) - IP30
  • Enclosure material - Polyamide
  • Fire resistance (UL 94) - V0
  • Grid dimension - 12.50 mm
  • Terminal degree of protection (IP) - IP20
  • Weight - 0.165 kg

Mounting / Installation

  • Conduct cross-section flexible max. - 0.2 mm²
  • Conduct cross-section flexible max. - 2.5 mm²
  • Conductor cross-section solid max. - 2.5 mm²
  • Conductor cross-section solid min. - 0.2 mm²
  • Connection type - Screw terminal
  • Mounting position - vertical horizontal
  • Mounting type - NS35/15, NS35/7.5 DIN rail

Output

  • LFD relay - No
  • Max. output current I a max - 58.00 mA
  • Output internal resistiance R i - 133.40 Ω
  • Output open circuit voltage U a - 21,9 V
  • Response time output - 20 ms
  • Switching delay ON/OFF - ≤ 20 ms
  • Switching state indication - Yellow LED "STAT"

Safety Data

  • Internal capacitance C i - negligible
  • Internal inductance L i - negligible
  • Max. current I o (Ex ia) - 188.00 mA
  • Max. permissible external capacitance C o for IIA - 2.930 μF
  • Max. permissible external capacitance C o for IIB - 0.830 μF
  • Max. permissible external inductance L o for IIA - 7.50 mH
  • Max. permissible external inductance L o for IIB - 4.000 mH
  • Max. Power P o - 1180.000 mW
  • Max. Voltage U o - 25.10 V
  • Safety-related maximum voltage - 253 V AC
1 - 4 of 4 Part Numbers