Yodify Product Library
Instantly add the GD10PE IR Extended Point Gas Detector and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

GD10PE IR Extended Point Gas Detector

Brand: Detcon Inc

The GD10PE is designed for critical applications involving large volumes of air with high velocity. 

In places where you need fast reliable detection of low gas concentrations. 

GD10PE is in a class of its own. The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. 

In addition the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package. 

With a measuring range of 0 to 20% LEL the GD10PE is 5 times more sensitive than standard point detectors. 

The GD10 range of infrared gas detectors differ from all other models, because they utilize silicon based solid-state infrared sources. 

The complete optomechanical design and constructions is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs. 

An industry standard HART interface is used for configuration of the levels as well as access to maintenance data.

Specifications

Brand

Accuracy

  • ± 1 % LEL (0 to 10 % LEL of Reading)
  • ± 1.4 % LEL (0 to 20 % LEL of Reading)

Approvals & Certifications

  • ATEX: 07-ATEX-1438
  • CSA: 1773527
  • IECEx: NEM 07.006
  • INMETRO: AEX-11698
  • SIL 2

Cable Entry

  • M20 EExe Cable Gland

Communication

  • HART

Consumption

  • 3.5 W - Approximately

Current

  • 4-20 mA - Sink

Electrical Connectors

  • 12 to 22 AWG
  • 3-Wire (0.5 to 1.5 mm²)

Enclosure, Body Material

  • 316 Stainless Steel - SIS2343

Environmental Protection

  • IP66
  • IP67

Humidity

  • 100 % Relative Humidity

Load Impedance

  • Maximum

Measuring Range

  • Ethylene 5,000 ppm
  • Methane 0 to 20 % LEL

Media

  • Gas - Hydrocarbons

Operating Temperature

  • -40° to 65° C (-40° to 149° F)

Output

  • 1 mA - Dirty Optics Dirt Accumulation
  • 2 mA - Early Clean Optics Prewarning
  • 4-20 mA - Standard

Response Time

  • 0.6 to 6 seconds

Stability

  • ± 1.4 LEL - Lifetime

Storage Temperature

  • -40° to 70° C (-40° to 158° F)

Supply Voltage

  • 18-32 Vdc
  • 24 Vdc

Temperature Range

  • 0° to 85° C (32° to 185° F) - Probe, Inside Duct

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more