Yodify Product Library
Instantly add the CamCor PRO Coriolis Flow Meter & Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
CamCor PRO Coriolis Flow Meter & Transmitter
Brand: CameronEquipped with a sophisticated transmitter (including a self diagnostics feature, large display, and field configurability via keypad), the Cameron PRO Series are cost-effective processgrade Coriolis flow meters.
Features- Extensive Self-Diagnostic Capabilities (Connection Faults, Pipeline Variations, Media Pulsation, etc.)
- Configurable via Keypad or Digital Communications
- Fast Response and Calculation Frequency
- User-Configurable Alarms
- Dual Independent Pulse Outputs, Dual Independent Current Outputs, One Status Output and One Status Input
- Enhanced Maintenance Functions (Event/user Change Logging and Downloads, Recoverable Factory Configuration and Calibration, etc.)
- Compatible with Modbus and HART Communication Protocols
Specifications
Brand
Ambient Temperature Range
- -40° to 55° C (-40° to 131° F)
Applications
- Oil & Gas Production Sites
Approvals & Certifications
- ATEX: 94/9/EC, EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012
- CSA: Class I, Zone 1, Ex d Ib IIB T4 Gb
- EMC Directive: 2004/108/EC, EN 55011: 1998, A1, 1999, A2: 2002, Group 1, Class B, EN 61000-6-2: 2001, EN061326-1: 2006
- IEC Ex: IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC 60079-11: 2011
Cable Length
- Remote Communication Cable: 16.4 feet (5 metres)
Communication
- Baud Rate: 9,600, 19,200, 38,400 bit/sec
- HART: Protocol Version 7, Hybrid Bell 202
- Modbus ASCII/RTU
- RS-485
Conduit Connection
- 3/4” NPT Female
Configuration
- Integral - Transmitter Configuration
- Separately Mounted - Transmitter Configuration
Consumption
- Maximum
Density Range
- 0.3 to 2 G/mL - Metering Range (Liquid)
Display
- 2 LEDs (Green & Red)
- Backlight Display (White, Orange)
- LCD Display (128 x 64 Pixels)
Electrical Connectors
- Minimum Conductor Size: 18 AWG
Enclosure Finish
- Paint Color: Light Gray (RAL7035)
- Paint Typical: Baked Enamel
Enclosure, Body Material
- 304 Stainless Steel
Environmental Protection
- Dust-Proof
- Explosion-proof
- IP66
- IP67
- Water-Proof
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ASME /ANSI
- 1-1/2” (DN 40) - 300# ASME /ANSI
- 1-1/2” (DN 40) - 600# ASME /ANSI
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ASME /ANSI
- 1” (DN 25) - 300# ASME /ANSI
- 1” (DN 25) - 600# ASME /ANSI
Flange Size - 1/2” (DN 15)
- 1/2” (DN 15) - 150# ASME /ANSI
- 1/2” (DN 15) - 300# ASME /ANSI
- 1/2” (DN 15) - 600# ASME /ANSI
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ASME /ANSI
- 2” (DN 50) - 300# ASME /ANSI
- 2” (DN 50) - 600# ASME /ANSI
Flange Type
- Raised Face (RF)
Flow Rate
- 0.106 to 8.46 gpm (0.40 to 32 LPM) - Guaranteed Min. Volumetric Flow Rate
- 0.264 to 21.2 gpm (1 to 85.2 LPM) - Min. Setting of Volumetric Flow Rate
- 0.88 to 70.5 lbs/min - Guaranteed Min. Mass Flow Rate
- 2.2 to 176 lbs/min - Min. Setting of Mass Flow Rate
- 2.64 to 212 gpm (10 to 802.5 LPM) - Max.
- 22 to 1,764 lbs/min - Max.
- 44.1 to 3,527 lbs/min - Max.
- 5.29 to 423 gpm (20 to 1,601 LPM) - Max.
Media
- Liquids - Applicable Fluid
Mounting Position
- Horizontal Piping
- Vertical Piping
NPT Connection
- 1/2” NPT Female
- 3/4” NPT Female
Output
- 1.5 V
- 10-30 V Min. - Pulse Output
- 13 V Min. - Pulse Output
- 4-20 mA DC, Max.
- 50 mA DC
Output Format
- Pulse Output
Output Impedence
- 2.2 kiloohms
Power Requirement
- 100-240 Vac, 50/60 Hz - Safety Rated
Power Supply
- 20-30 Vdc
- 85-264 Vac 50/60 Hz
Range
- Transmission Length: Max.
Repeatability
- ± 0.1 % of Reading (± 1/2 of Zero Stability)
Resistance
- Analog Output Load Resistance: 600 ohms
- Pulse Output ON Resistance: ≥ 0.6 ohms
Response Time
- 25 to 50 milliseconds
Sensor, Probe Type
- Infrared
Size
- Nominal Size: 1/2” to 2” (12.7 to 51 mm)
Stability
- 0.0033 to 0.265 lbs/min - Zero Stability
Temperature Range
- -40° to 125° C (-40° to 257° F)
Tri-Clamp Connection
- 1” IDF Ferrule
- 1/2” IDF Ferrule
- 1-1/2” IDF Ferrule
- 2” IDF Ferrule
Uncertainty
- ± 0.003 G/mL - Uncertainty of Density (Liquid)
- ± 0.1 % of Full Scale - Analog Output Uncertainty
- ± 0.2 % of Reading (± Zero Stability) - Uncertainty of Flow Rate
Wetted Materials
- 316L Stainless Steel