Brand: R. STAHL AGThe 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals.
The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardized for all variants.
Features- For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
- Compact, space-saving devices that are easy to install on a DIN rail
- Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
1 - 12 of 30 Part Numbers
158818
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 20.00 ... 35.00 V
- Power supply - Uncontrolled, 20 - 35 V DC
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - > 26 V ≤ 35 mA
- Max. current I o - 97.0 mA
- Max. power P o - 679.000 mW
- Max. resistance R max - 327.00 Ω
- Maximum output current I max - 35 mA
- Min. resistance R min - 292.00 Ω
- Nominal voltage U N - 20.00 ... 35.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - Pos. poten. w/diode feedback
- Potential Ch 1 - positive potential
- potential CH 2 - Evaluation barrier +potential
- Rated operational voltage DC - 26.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - 3-wire PNP sensors, proximity switches, encoders, photocells; field circuit floating
- Product Description - Dual-channel safety barrier
- Product Type - 9002/13-280-100-041
- Product Variant - Series 9002/13, Safety barriere potential: positive / diode return barrier potential: positive
- Title Product Variant Technical Data - 9002/13-280-100-041 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 12.000 mH
- Max. permissible external inductance L o for IIC - 1.800 mH
- Max. voltage U o - 28.00 V
158830
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 20.00 ... 35.00 V
- Power supply - Uncontrolled, 20 - 35 V DC
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - 35 V ≤ 10 mA
- Max. current I o - 118.0 mA
- Max. power P o - 740.000 mW
- Max. resistance R max - 243.00 Ω
- Maximum output current I max - 86 mA
- Min. resistance R min - 216.00 Ω
- Nominal voltage U N - 20.00 ... 35.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - Pos. poten. w/diode feedback
- Potential Ch 1 - positive potential
- potential CH 2 - Evaluation barrier +potential
- Rated operational voltage DC - 22.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Positioner, i/p converter; field circuit floating
- Product Description - Dual-channel safety barrier
- Product Type - 9002/13-252-121-041
- Product Variant - Series 9002/13, Safety barriere potential: positive / diode return barrier potential: positive
- Title Product Variant Technical Data - 9002/13-252-121-041 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.820 μF
- Max. permissible external capacitance C o for IIC - 0.107 μF
- Max. permissible external inductance L o for IIB - 7.400 mH
- Max. permissible external inductance L o for IIC - 1.300 mH
- Max. voltage U o - 25.20 V
158845
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 25.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. power P o - 650.000 mW
- Max. resistance R max - 358.00 Ω
- Maximum output current I max - 69 mA
- Min. resistance R min - 321.00 Ω
- Nominal voltage U N - 25.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - negative potential
- Potential Ch 1 - negative potential
- potential CH 2 - negative potential
- Rated operational voltage DC - 25.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - variable
- Product Description - Dual-channel safety barrier
- Product Type - 9002/00-280-186-001
- Product Variant - Series 9002/00, Potential: negative / negative
- Title Product Variant Technical Data - 9002/00-280-186-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 93.0 mA
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 13.000 mH
- Max. permissible external inductance L o for IIC - 2.000 mH
- Max. voltage U o - 28.00 V
158848
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 25.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 93.0 mA
- Max. resistance R max - 358.00 Ω
- Maximum output current I max - 69 mA
- Min. resistance R min - 321.00 Ω
- Nominal voltage U N - 25.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - positive potential
- Potential Ch 1 - positive potential
- potential CH 2 - positive potential
- Rated operational voltage DC - 25.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Description - dual channel
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - variable
- Product Description - Dual-channel safety barrier
- Product Type - 9002/11-280-186-001
- Product Variant - Series 9002/11; Potential: positive / positive
- Title Product Variant Technical Data - 9002/11-280-186-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 13.000 mH
- Max. permissible external inductance L o for IIC - 2.000 mH
- Max. Power P o - 650.000 mW
- Max. voltage U o - 28.00 V
158852
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 90.0 mA
- Max. power P o - 630.000 mW
- Max. resistance R max - 358.00 Ω
- Maximum output current I max - 67 mA
- Min. resistance R min - 321.00 Ω
- Nominal voltage U N - 24.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - Pos. poten. w/diode feedback
- Potential Ch 1 - positive potential
- potential CH 2 - Evaluation barrier +potential
- Rated operational voltage DC - 24.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Solenoid valves, horns, signal beacons, I / P converter, strain gauge supply
- Product Description - Dual-channel safety barrier
- Product Type - 9002/13-280-093-001
- Product Variant - Series 9002/13, Safety barriere potential: positive / diode return barrier potential: positive
- Title Product Variant Technical Data - 9002/13-280-093-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 14.000 mH
- Max. permissible external inductance L o for IIC - 2.200 mH
- Max. voltage U o - 28.00 V
158857
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 107.0 mA
- Max. power P o - 749.000 mW
- Max. resistance R max - 290.00 Ω
- Maximum output current I max - 82 mA
- Min. resistance R min - 269.00 Ω
- Nominal voltage U N - 24.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - Pos. poten. w/diode feedback
- Potential Ch 1 - positive potential
- potential CH 2 - Evaluation barrier +potential
- Rated operational voltage DC - 24.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Solenoid valves, horns, signal beacons, I / P converter, strain gauge supply
- Product Description - Dual-channel safety barrier
- Product Type - 9002/13-280-110-001
- Product Variant - Series 9002/13, Safety barriere potential: positive / diode return barrier potential: positive
- Title Product Variant Technical Data - 9002/13-280-110-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 9.600 mH
- Max. permissible external inductance L o for IIC - 1.350 mH
- Max. Voltage U o - 28.00 V
158860
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 25.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. resistance R max - 358.00 Ω
- Maximum output current I max - 69 mA
- Min. resistance R min - 321.00 Ω
- Nominal voltage U N - 25.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - positive potential
- Potential Ch 1 - positive potential
- potential CH 2 - positive potential
- Rated operational voltage DC - 6.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - 2-wire transmitter, conversion to 1 ... 5 V
- Product Description - Dual-channel safety barrier
- Product Type - 9002/11-280-293-021
- Product Variant - Series 9002/11; Potential: positive / positive
- Title Product Variant Technical Data - 9002/11-280-293-021 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 89.0 mA
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 14.000 mH
- Max. permissible external inductance L o for IIC - 2.200 mH
- Max. Power P o - 630.000 mW
- Max. voltage U o - 28.00 V
158864
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 25.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 89.0 mA
- Max. resistance R max - 358.00 Ω
- Maximum output current I max - 69 mA
- Min. resistance R min - 321.00 Ω
- Nominal voltage U N - 25.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - positive potential
- Potential Ch 1 - positive potential
- potential CH 2 - positive potential
- Rated operational voltage DC - 6.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - variable
- Product Description - Dual-channel safety barrier
- Product Type - 9002/11-280-293-001
- Product Variant - Series 9002/11; Potential: positive / positive
- Title Product Variant Technical Data - 9002/11-280-293-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 14.000 mH
- Max. permissible external inductance L o for IIC - 2.200 mH
- Max. Power P o - 630.000 mW
- Max. Voltage U o - 28.00 V
158873
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Nominal voltage - 24.00 V
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. power P o - 760.000 mW
- Max. resistance R max - 296.00 Ω
- Maximum output current I max - 91 mA
- Min. resistance R min - 264.00 Ω
- Nominal voltage U N - 24.00 V
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - positive potential
- Potential Ch 1 - positive potential
- potential CH 2 - positive potential
- Rated operational voltage DC - 24.00 V
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - 3-wire NPN inputs, e.g. proximity switches, encoders, photocells; field circuit floating
- Product Description - Dual-channel safety barrier
- Product Type - 9002/11-280-112-001
- Product Variant - Series 9002/11; Potential: positive / positive
- Title Product Variant Technical Data - 9002/11-280-112-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 109.0 mA
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 9.000 mH
- Max. permissible external inductance L o for IIC - 1.300 mH
- Max. Voltage U o - 28.00 V
158877
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +60 °C
- Ambient temperature max. - +60 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. power P o - 330.000 mW
- Max. resistance R max - 730.00 Ω
- Min. resistance R min - 657.00 Ω
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - star barrier
- Potential Ch 1 - star barrier
- potential CH 2 - star barrier
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Acceleration sensor
- Product Description - Dual-channel safety barrier
- Product Type - 9002/77-280-094-001
- Product Variant - Series 9002/77, Star barrier / star barrier
- Title Product Variant Technical Data - 9002/77-280-094-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. Current I o - 94.0 mA
- Max. permissible external capacitance C o for IIB - 0.650 μF
- Max. permissible external capacitance C o for IIC - 0.083 μF
- Max. permissible external inductance L o for IIB - 30.000 mH
- Max. permissible external inductance L o for IIC - 10.100 mH
- Max. voltage U o - 28.00 V
158881
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C
- Ambient temperature max. - +50 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 148.0 mA
- Max. resistance R max - 180.00 Ω
- Min. resistance R min - 159.00 Ω
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - star barrier
- Potential Ch 1 - star barrier
- potential CH 2 - star barrier
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Voltage sources such as thermocouple, strain gauge signal
- Product Description - Dual-channel safety barrier
- Product Type - 9002/77-220-296-001
- Product Variant - Series 9002/77, Star barrier / star barrier
- Title Product Variant Technical Data - 9002/77-220-296-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 1.140 μF
- Max. permissible external capacitance C o for IIC - 0.165 μF
- Max. permissible external inductance L o for IIB - 7.200 mH
- Max. permissible external inductance L o for IIC - 1.350 mH
- Max. Power P o - 810.000 mW
- Max. voltage U o - 22.00 V
158885
For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more
Compact, space-saving devices that are easy to install on a DIN rail
Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
Ambient Conditions
- Ambient temperature - -20 °C ... +50 °C
- Ambient temperature max. - +50 °C
- Ambient temperature min. - -20 °C
- Relative humidity max. - 95% on average, no condensation
- Storage temperature - -20 °C ... +75 °C
- Storage temperature max. - +75 °C
- Storage temperature min. - -20 °C
- Temperature influence - ≤ 0,25 %/10K
Auxiliary power
- Power supply - Controlled, nominal voltage
Electrical Data
- Channel - 1 2 1 + 2
- Leakage current I leck for U N - ≤ 2 µA
- Leakage current I leck for U N 2 - (Unless specified otherwise)
- Max. current I o - 73.0 mA
- Max. power P o - 400.000 mW
- Max. resistance R max - 358.00 Ω
- Min. resistance R min - 321.00 Ω
- Number of channels - 2
- Ohmic current limiting using frequency - ≤ 50 kHz
- Ohmic current limiting using frequency >= 50 mA - ≤ 100 kHz
- Potential - star barrier
- Potential Ch 1 - star barrier
- potential CH 2 - star barrier
Explosion Protection
- Application range (zones) - 2, 22
- ATEX dust certificate - PTB 01 ATEX 2053 X
- ATEX gas certificate - PTB 01 ATEX 2053 X
- Certificate EAC - TS RU C-DE.ГБ04.B.00651
- Certificates - ATEX (PTB), Brazil (ULB), Canada (CSA), China (CQST), EAC (STV), IECEx (PTB), India (PESO), Korea (KGS), USA (FM), USA (UL)
- Dust explosion protection ATEX - II (1) D [Ex ia Da] IIIC
- Dust explosion protection EAC - [Ex ia Da] IIIC
- Dust explosion protection IECEx - [Ex ia Da] IIIC
- Ex interface zone - 0, 1, 2, 20, 21, 22
- Further information - see respective certificate and operating instructions
- Gas explosion protection ATEX - II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc
- Gas explosion protection EAC - 2 Ex nA [ia Ga] IIC T4 Gc X
- Gas explosion protection IECEx - Ex nA [ia Ga] IIC/IIB T4 Gc
- IECEX dust certificate - IECEx PTB 08.0057X
- IECEX gas certificate - IECEx PTB 08.0057X
- Installation - in Zone 2, Division 2 and in safe area
General
- Functional Description - The 9002 series INTRINSPAK two-channel safety barriers enable the intrinsically safe operation of virtually all field devices. The comprehensive portfolio and the combination of safety barriers cover a wide variety of signals. The devices are incredibly robust and require very little space. The back-up fuse is a convenient feature as it is standardised for all variants.
- Highlights - For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more Compact, space-saving devices that are easy to install on a DIN rail Quick to install as barriers can be simultaneously snapped onto rail and connected to PE
- Particularly suitable for - Voltage sources such as thermocouple, strain gauge signal
- Product Description - Dual-channel safety barrier
- Product Type - 9002/77-220-146-001
- Product Variant - Series 9002/77, Star barrier / star barrier
- Title Product Variant Technical Data - 9002/77-220-146-001 safety barrier
- WebCode - 9002A
Mechanical Data
- Clamping range max. - 1.50 mm²
- Connection cross-section - 4.0 mm²
- Degree of protection (IP) - IP40
- Enclosure material - Polyamide 6GF
- Length - 12.000 mm
- Mounting depth - 72.000 mm
- Number of connection terminals - 4
- Terminal degree of protection (IP) - IP20
- Type of connection cable - Finely stranded, solid
- Weight - 0.110 kg
- Width - 103.000 mm
Mounting / Installation
- Connection type - 2 PA
Safety Data
- Max. permissible external capacitance C o for IIB - 1.140 μF
- Max. permissible external capacitance C o for IIC - 0.165 μF
- Max. permissible external inductance L o for IIB - 26.000 mH
- Max. permissible external inductance L o for IIC - 7.000 mH
- Max. Voltage U o - 22.00 V