Series 608 Intrinsically Safe Differential Pressure Transmitter
Brand: Dwyer Instruments, LLCThe Dwyer Series 608 Differential Pressure Transmitters convert positive, negative (vacuum), or differential pressures of clean, dry air or other non-conductive, noncorrosive gases into a standard two wire, 4-20 mA output signal.
The use of an ultrathin silicon diaphragm enables precision measurement of differential pressures as low as 0.1 Inches WC while withstanding high static working pressures up to 100 psig (6.89 bar).
The Series 608 transmitters are FM approved intrinsically safe for use in the specified hazardous locations when used with an approved intrinsic safety barrier.
The rugged NEMA 4X, stainless steel housing makes this transmitter ideal for use in industrial and process plant environments.
Features- High accuracy at low pressure ranges provides exceptional measurement for insuring tight-control and minimizing costly out of specification conditions
- Intrinsically safe for use in the specified hazardous locations meets specifications where pressure transmission and safety cannot be compromised
- NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
1 - 12 of 24 Part Numbers
608-00
608-00B
608-01
608-01B-NISTCAL-PT1
- Pressure Range - Inches WC: 0 to ± 0.25
- Certificates - NIST Traceable Calibration Certificate
608-02-NISTCAL-PT1
- Pressure Range - Inches WC: 0 to 0.5
- Certificates - NIST Traceable Calibration Certificate
608-02B
608-03-NISTCAL-PT1
- Pressure Range - Inches WC: 0 to 1
- Certificates - NIST Traceable Calibration Certificate
608-03B
1 - 12 of 24 Part Numbers
Specifications
Brand
Accuracy
- ± 0.25 % of Full Scale
- ± 0.5 % of Full Scale
Approvals & Certifications
- FM
Compensated Temperature
- -18° to 71° C (0° to 160° F)
Consumption
- 4-20 mA
Diaphragm Material
- Silicone
Electrical Connectors
- Screw Terminal
- Two 1/2” NPT Female Conduit
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP66
- NEMA 4X
Loop Resistance
- DC: 0 to 1045 ohms, Max.
Media
- Clean / Dry Air
- Compatible & Combustible Gases
NACE & NIST
- NIST
NPT Connection
- 1/4” NPT Female
Output
- 4-20 mA (Direct Current)
Power Requirement
- 12-36 Vdc (2-Wire)
Pressure Range
- Inches WC: 0 to 25
Pressure Type
- Differential
Response Time
- 250 milliseconds
Span & Zero Adjustments
- Potentiometers for Zero & Span
Stability
- ± 0.5 % of Full Scale Output/Year
Temperature Effect
- 0.25 % Accuracy: ± 0.01 % of Full Scale/°F
- 0.5 % Accuracy: ± 0.02 % of Full Scale/°F
Temperature Range
- -28° to 85° C (-20° to 185° F)
- Lab Fume Hood Control
- Clean Room Applications
- Flow Measurements & Controls
- Filter Monitoring
- Furnace Draft Measurement
- Process Control