Yodify Product Library
Instantly add the AP3203 Omnidirectional Hotwire Probe and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

AP3203 Omnidirectional Hotwire Probe

Brand: Delta OHM S.R.L.

Omnidirectional hotwire probe.

1 - 3 of 3 Part Numbers
AP3203
AP3203
Probe Stem Ø 8 mm, Length 230 mm. Cable Length 2 Metres. Equipped With SICRAM Module.
Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0…+80 °C. Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module.
Sensor: NTC 10 kΩ
Resolution: 0.01 m/s
Accuracy: ± (0.05 + 5% measure) m/s
Temperature drift@ 20 °C: 0.06 %/°C
Long term stability: 0.12 °C/year
Connection 8-pole female DIN45326 connector
Protection dimensions Ø=80 mm
In combination with the data loggers HD32.1 and HD32.3TCA, the probe is used for calculating the following indices:
  • PMV – Predicted Average Rating
  • PPD – Dissatisfied percentage
  • TU – Turbulence
  • DR – Draught rate
The probe is also used for calculating Mean radiant temperature.
AP3203.2
AP3203.2
Probe Stem Ø 8 mm, Length 230 mm.
Measuring range: air speed 0.02 ÷ 5 m/s, temperature 0…+80 °C. Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module.
Sensor: NTC 10 kΩ
Resolution: 0.01 m/s
Accuracy: ± (0.05 + 5% measure) m/s
Temperature drift@ 20 °C: 0.06 %/°C
Long term stability: 0.12 °C/year
Connection 8-pole female DIN45326 connector
Protection dimensions Ø=80 mm
In combination with the data loggers HD32.1 and HD32.3TCA, the probe is used for calculating the following indices:
  • PMV – Predicted Average Rating
  • PPD – Dissatisfied percentage
  • TU – Turbulence
  • DR – Draught rate
The probe is also used for calculating Mean radiant temperature.
AP3203F
AP3203F
Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module. For Cold Environments
Measuring range: air speed 0.02 ÷ 5 m/s, temperature -30…+30 °C. Probe stem Ø 8 mm, length 230 mm. Cable length 2 metres. Equipped with SICRAM module.
In combination with the data logger HD32.1, the probe is used for calculating the following indices:
  • IREQ – Required insulation
  • DLE – Exposure time limit
  • RT – Required recovery time
  • WCI – Wind Chill Index
  • PMV – Predicted Average Rating
  • PPD – Dissatisfied percentage
  • DR – Draught rate
The probe is also used for calculating Mean radiant temperature.

1 - 3 of 3 Part Numbers
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more