Yodify Product Library
Instantly add the Solenoid Operated Unloading Relief Valve and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
Solenoid Operated Unloading Relief Valve
Brand: Parker - Fluid Control DivisionParker’s solenoid operated unloading relief valves are a combination of a solenoid unloader and system relief in a single valve and cavity; capable of flows up to 60 lpm (16 gpm) and pressures to 280 bar (4000 psi).
Parker’s solenoid operated unloading relief valve provides cost and space savings by combining a solenoid operated unloader valve and a system relief into a single cartridge valve and cavity.
By utilizing a pilot operated design, this valve is capable of handling flows up to 60 lpm (16 gpm) and pressures as high as 280 bar (4000 psi).
This valve is ideal for unloading circuits and allows pumps to unload to the tank at low pressure when no current is applied to the coil, therefore reducing power consumption and heat generation.
Once current is applied, the valve will act as standard relief and can be used in several applications within mobile or industrial hydraulic systems.
Additional Technical Insight
Parker’s AS04G2 provides cost and space savings by combining a solenoid operated unloader valve and a system relief into a single 10-2 cavity.
By utilizing a pilot operated design, the AS04G2 is capable of handling flows up to 16 GPM and pressures as high as 4000 psi.
When no current is applied to the coil, pump flow is allowed to unload to the tank at low pressure therefore reducing power consumption and heat generation.
Once current is applied, the valve will prevent the pump from unloading to tank as long as the pressure remains below the mechanically set maximum pressure.
Parker HCS offers four standard pressure settings, and can provide customer specific tamper-proof fixed settings upon request.
The full 100-4000 psi max pressure range can be achieved by ordering any of the pre-set adjustable versions and adjusting the setting in the application.
The common cavity design enables this valve to offer design flexibility in many applications.
It can be integrated into manifolds, mounted in-line with standard line-bodies, or sandwich mount into a D03 stack using our Cartpak BD03-PT stackable body.
By utilizing Parker’s IP69K Super Coil technology, the AS04G2 can be used in a wide range of environmental conditions
Features- Two functions in one valve
- Integral 250 micron pilot flow filter
- All external parts zinc plated
- Factory set relief pressure or adjustable option
- Hardened, precision ground parts for durability
1 - 12 of 20 Part Numbers
AS04G2T14N
AS04G2T14V
AS04G2T20N
AS04G2T20V
AS04G2T22N
AS04G2T22V
AS04G2T27N
AS04G2T27V
AS04G2TN
AS04G2TV
AS04G2Z14N
AS04G2Z14V
1 - 12 of 20 Part Numbers
Specifications
Coil Type
- ⅝” Super Coil High Watt (CAP)
Weight
- 0.45 kg / 0.98 lbs
Standard Setting Pressure
- 1800 - 4000 psi / 124 - 276 bar
Flow Direction
- Nose to Side (1 - 2)
Function
- Relieving
Coil Nut Torque
- Finger Tight
Type / Configuration
- Normally Open
Pressure Range Adjustment
- 100 - 4000 psi (6.9 - 276 bar)
Installation Torque
- 50 Nm / 37 lbs/ft
Maximum Inlet Pressure
- 4000 psi / 276 bar
Maximum Tank Pressure
- 1000 psi / 70 bar
Seal Material
- Nitrile, Fluorocarbon
Minimum Pressure Differential
- 100 psi / 6.9 bar
Operating Temperature
- -30°F to +250°F, -15°F to +400°F
- -34°C to +121°C, -26°C to +204°C
Rated Fluid Viscosity
- Mineral-based or Synthetic with Lubricating Properties at Viscosities of 45-2000 SSU (6 to 420 cSt)
Rated Flow
- 16 gpm / 60 Lpm
Reseat Pressure
- 90% of Cracking Pressure
Adjustment Type
- Tamper Resistant, Push & Turn
Filtration Ratings
- ISO 4406: 1999 Code 18/16/13
Valve Material
- All Parts Steel. All Operating Parts Hardened Steel
Cavity Size
- C10-2
Leak Rate
- 5 cc/min for Every 100 psi of Setting
- Pump Unloader
- System Relief
- Markets:
- Agriculture
- Construction
- Material Handling
- Miscellaneous Industrial
- Miscellaneous Manufacturing
- Miscellaneous Mobile