Brand: Status InstrumentsThe SEM1801XTC/18022XTC Din rail temperature transmitter accepts thermocouple temperature sensors and converts the sensor output over a configured range to a standard industrial (4-20 mA) transmission signal.
Two versions are available; single or dual channel ATEX / IECEx approved for hazardous areas.
PC configuration allows the user to select TC type, Range, Filter, units, linearisation and Burnout direction, without requiring calibration equipment.
Additionally, the user may read live process data when connected to the PC (in the safe area), this allows for sensor offset, and output alignment calibration, where the user can enter values to match the actual process and therefore reducing system errors.
Features- K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W)
- UKEX, ATEX And IECEx Approved
- Single And Dual Channel Versions
- Sensor Offset And Output Alignment
- Isolation Input To Output
Specifications
Brand
Accuracy
- (mA Output/2,000) or 5 µA whichever is greater, Drift 1 µA/°C
- ± 0.1 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error) - for K, J, E, N, L, U, B, C, D, W, R, S Thermocouples
- ± 0.2 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error) - for T Thermocouple
- Cold Junction: ± 0.05° C/°C
- Cold Junction: ± 0.2° C (± 0.36° F)
Ambient Temperature Range
- Configuration Ambient: 10° to 30° C (50° to 86° F)
Approvals & Certifications
- ATEX - CE II 1 GD Ex ia IIC T4 Ga Ex iaD 20 T135° C Da Tamb: -40° to 70° C (-40° to 158° F)
- CE BS EN 61326
- IEC Ex
Burn-Out
- Downscale - 3.8 mA
- Up Scale - 21.5 mA
Communication
- Baud Rate: 1,200 bit/sec
- USB 2.0
Current
- 2-Wire 4-20 mA Current Loop
Electrical Connectors
- Screw Terminals 2.5 mm, Max.
Environmental Protection
- IP65
Humidity
- 10 to 90 % Relative Humidity, Non-Condensing
Isolation
- Input to Output 500 Vdc
Operating Temperature
- -40° to 70° C (-40° to 158° F)
Output
- 2-Wire 4-20 mA Current Loop
Output Load
- Maximum
Power
- < 1 W Full Power Per Channel
Power Supply Effect
- Loop Effect: ± 0.2 µA/V
Response Time
- 500 milliseconds
- Start Up 5 seconds
- Update 160 milliseconds
Sensor, Probe Type
- Standard TC: C (W5) Thermocouple
- Standard TC: D (W3) Thermocouple
- Standard TC: E Thermocouple
- Standard TC: G (W) Thermocouple
- Standard TC: J Thermocouple
- Standard TC: K Thermocouple
- Standard TC: L Thermocouple
- Standard TC: N Thermocouple
- Standard TC: R Thermocouple
- Standard TC: S Thermocouple
- Standard TC: T Thermocouple
- Standard TC: U Thermocouple
Storage Temperature
- -50° to 70° C (-58° to 158° F)
Supply Voltage
- Loop Supply: 10-30 Vdc Per Channel
System Requirements
- Equipment: PC Running Windows® XP or Later
- Equipment: USB Configurator
Temperature Range
- Cold Junction: -40° to 85° C (-40° to 185° F)
Thermal Drift
- Thermocouple Offset 0.1° C/°C
- Thermocouple Offset: 0.05° C/°C of Span
Update Time
- Warm-Up: 2 minutes