Yodify Product Library
Add the LMT200 External Mount Magnetostrictive Level Transmitter to your store or catalog  
Book Your Demo and See How
or create your store

LMT200 External Mount Magnetostrictive Level Transmitter

Brand: ABB Group

The LMT Series of level transmitters is a modular range of field mounted, advanced microprocessor-based electronic transmitters, utilizing multiple sensor technologies.

Accurate and reliable measurement of liquid level and interface are provided in even the most difficult and hazardous  industrial environments.
Features
  • Calibrated from the factory
  • High Accuracy: 0.01% of Full Scale or ±1.27 mm
  • Never Requires Re-Calibration: Set It & Forget It
  • Easy setup with waveform display
  • Not affected by agitation, foam or emulsion layers
  • No oscilloscope required
  • Designed to Mount Externally to K-TEK KM26 or other
  • Magnetic Level Gauge
  • Superior Sensor (Patent #5,473,245)
  • Local Indication with HMI Display
  • Dual Compartment Housing with Separate Field Terminal Compartment
  • Loop Powered to 15.24 m (50 ft) Probe Length
  • Total and/or Interface Level Measurement
  • Temperature Range: -195.5° to 426.6° C (-320° to 800° F) with options
  • Field Replaceable / Upgradable Electronics Module
  • Built-in RFI / EMI Filter
  • Digital Communications
  • Online Self-verification
  • Options:
    • Two Level Indications
    • Glass Viewing Window
    • 316 Stainless Steel Enclosure
    • Built-in surge protection

1 - 12 of 720 Part Numbers
LMT200.B4.S6.C1.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
External Mount Magnetostrictive Level Transmitter
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing  - Aluminum with 2 x M20 x 1.5
  • Display  - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output  - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length  - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Aluminum with 2 x NPT 1/2"
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Stainless Steel with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B2.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Right Connected Electronic Housing
  • Housing - Aluminum with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B2.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Right Connected Electronic Housing
  • Housing - Aluminum with 2 x NPT 1/2"
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.B2.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Right Connected Electronic Housing
  • Housing - Stainless Steel with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.T1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Top Left Connected Electronic Housing
  • Housing - Aluminum with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.T1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Top Left Connected Electronic Housing
  • Housing - Aluminum with 2 x NPT 1/2"
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C1.T1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Top Left Connected Electronic Housing
  • Housing - Stainless Steel with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C3.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Aluminum with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C3.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Aluminum with 2 x NPT 1/2"
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
LMT200.B4.S6.C3.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
  • Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
  • Probe Material - 316/L SS
  • Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
  • Mounting Orientation - Bottom Left Connected Electronic Housing
  • Housing - Stainless Steel with 2 x M20 x 1.5
  • Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
  • Output - Single 4-20 mA + HART
  • SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
  • Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
  • Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
  • Signal Cable Length - 10 m (Approx. 33 ft)
  • Surge Protector - Surge/Transient Protector
  • Special Other - Special Paint or Treatment on Housing
  • Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
  • Certificate - None
  • Drawings - Drawings for Approval Required Prior to Construction
  • Documentation Language - English
  • Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
  • Measuring Length - Customized Insertion Length in inches
1 - 12 of 720 Part Numbers

Specifications

Brand

Accuracy

  • ± 0.01 % of Full Scale or ± 1.27 mm, Whichever is Greater

Repeatability

  • ± 0.005 % of Full Scale or 0.315 mm (0.012 in), Whichever is Greater

Non-Linearity

  • ± 0.01 % of Full Scale or 0.86 mm (0.034 in), Whichever is Greater

Measuring Span

  • Minimum 76.2 mm (3.0 in)

Process Pressure

  • Up to 165.48 bar (2,400 psig)
  • Standard -1 to 124.1 bar (-14.7 to 1,800 psig)

Process Temperature

  • -195.5° to 426.6° C (-320° to 800° F)

Communication

  • FOUNDATION Fieldbus
  • HART

Enclosure/Body Material

  • Enclosure: Cast Low Copper Aluminum with Powder Coat
  • Enclosure: 316/L Stainless Steel

Supply Voltage

  • 9.0-32 Vdc for FOUNDATION Fieldbus
  • 12-43 Vdc for 4-20 mA HART Loop-Powered

Ambient Temperature

  • -40° to 85° C (-40° to 185° F)

Humidity

  • 0 to 100 % RH

Remote Transmitter

  • Standard Remote Distances of 5 m (16 ft), 10 m (33 ft), 20 m (66 ft), 30 m (98 ft)

Environmental Protection

  • IP66, NEMA 4X

Certifications & Approvals

  • SIL 2/3
  • FM
  • KOSHA
  • EAC
  • ATEX/IECEx
  • NEPSI
  • INMETRO

Material of Construction

  • Sensor Tube: 316/L Stainless Steel

Probe Length

  • 304.8 mm to 15.24 m (1 to 50 ft)
  • 90 Degree Probes (SEH Option) 304.8 mm to 7.62 m (1 to 25 ft)

Mounting

  • Stainless Steel Clamps for KM26 Magnetic Level Gauge Chamber Included, Optional Vibration Isolation Mounts

Electrical Connection

  • Two M20 x 1.5 or Two 1/2" FNPT, Adapters and Bus Connectors Also Available

Damping

  • Field Adjustable 0.1 to 60 s

  • Oil & Gas
  • Chemicals
  • Refineries
  • Power Generation

Documentation