Yodify Product Library
Add the LMT200 External Mount Magnetostrictive Level Transmitter to your store or catalog
Book Your Demo and See How
or create your store
LMT200 External Mount Magnetostrictive Level Transmitter
Brand: ABB GroupThe LMT Series of level transmitters is a modular range of field mounted, advanced microprocessor-based electronic transmitters, utilizing multiple sensor technologies.
Accurate and reliable measurement of liquid level and interface are provided in even the most difficult and hazardous industrial environments.
Features- Calibrated from the factory
- High Accuracy: 0.01% of Full Scale or ±1.27 mm
- Never Requires Re-Calibration: Set It & Forget It
- Easy setup with waveform display
- Not affected by agitation, foam or emulsion layers
- No oscilloscope required
- Designed to Mount Externally to K-TEK KM26 or other
- Magnetic Level Gauge
- Superior Sensor (Patent #5,473,245)
- Local Indication with HMI Display
- Dual Compartment Housing with Separate Field Terminal Compartment
- Loop Powered to 15.24 m (50 ft) Probe Length
- Total and/or Interface Level Measurement
- Temperature Range: -195.5° to 426.6° C (-320° to 800° F) with options
- Field Replaceable / Upgradable Electronics Module
- Built-in RFI / EMI Filter
- Digital Communications
- Online Self-verification
- Options:
- Two Level Indications
- Glass Viewing Window
- 316 Stainless Steel Enclosure
- Built-in surge protection
1 - 12 of 720 Part Numbers
LMT200.B4.S6.C1.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
1 - 12 of 720 Part Numbers
Specifications
Brand
Accuracy
- ± 0.01 % of Full Scale or ± 1.27 mm, Whichever is Greater
Repeatability
- ± 0.005 % of Full Scale or 0.315 mm (0.012 in), Whichever is Greater
Non-Linearity
- ± 0.01 % of Full Scale or 0.86 mm (0.034 in), Whichever is Greater
Measuring Span
- Minimum 76.2 mm (3.0 in)
Process Pressure
- Up to 165.48 bar (2,400 psig)
- Standard -1 to 124.1 bar (-14.7 to 1,800 psig)
Process Temperature
- -195.5° to 426.6° C (-320° to 800° F)
Communication
- FOUNDATION Fieldbus
- HART
Enclosure/Body Material
- Enclosure: Cast Low Copper Aluminum with Powder Coat
- Enclosure: 316/L Stainless Steel
Supply Voltage
- 9.0-32 Vdc for FOUNDATION Fieldbus
- 12-43 Vdc for 4-20 mA HART Loop-Powered
Ambient Temperature
- -40° to 85° C (-40° to 185° F)
Humidity
- 0 to 100 % RH
Remote Transmitter
- Standard Remote Distances of 5 m (16 ft), 10 m (33 ft), 20 m (66 ft), 30 m (98 ft)
Environmental Protection
- IP66, NEMA 4X
Certifications & Approvals
- SIL 2/3
- FM
- KOSHA
- EAC
- ATEX/IECEx
- NEPSI
- INMETRO
Material of Construction
- Sensor Tube: 316/L Stainless Steel
Probe Length
- 304.8 mm to 15.24 m (1 to 50 ft)
- 90 Degree Probes (SEH Option) 304.8 mm to 7.62 m (1 to 25 ft)
Mounting
- Stainless Steel Clamps for KM26 Magnetic Level Gauge Chamber Included, Optional Vibration Isolation Mounts
Electrical Connection
- Two M20 x 1.5 or Two 1/2" FNPT, Adapters and Bus Connectors Also Available
Damping
- Field Adjustable 0.1 to 60 s
- Oil & Gas
- Chemicals
- Refineries
- Power Generation
Documentation
Data Sheets
- Version matrix - LMT | Magnetostrictive Technical description pdf
- Driver LMT Magnetostrictive FF LMT100, LMT200, LMT300 Level Transmitter Technical Description pdf
- Driver LMT Magnetostrictive HART Supplement Info Driver pdf
- LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER data sheet pdf 13.1 MB
Product Manuals
- LMT Series Magnetostrictive level transmitter LMT100 & 200 models Commissioning Instructions pdf
- LMT Series Magnetostrictive level transmitter LMT100 & 200 models Operating Instructions-Hart.pdf
- LMT Series Safety manual for magnetostrictive level transmitter safety manual pdf
- LMT100 and LMT200 Magnetostrictive level transmitters Foundation Fieldbus operation instruction pdf
Bulletin
Certifications
- Certificate - ATEX IS FM17ATEX0062X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - ATEX nA ic FM17ATEX0063X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - ATEX XP FM17ATEX0064X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - CRN | LMT100 (PMU Warminster) pdf
- Certificate - FMC FM17CA0124X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - FMUS XP IS FM17US0243X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - IECEx XP IS FME 17.0004X 1 | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - LMT | Registration 1A9D Device 02 HART pdf
- Certificate - LMT 100 & LMT200 | Registration FDI 01.00.00 HART pdf
- Certificate - LMT Series | NEPSI Ex d GYJ21.3373X | Shanghai & Warminster | expires 10.2026 pdf
- Certificate - LMT Series | NEPSI nA ic GYJ21.3374X | Shanghai & Warminster | expires 10.2026 pdf
- Certificate - LMT100 & LMT200 | EAC EMC | EN & RU pdf
- Certificate - LMT100 & LMT200 | EAC Ex | EN & RU | Warminster pdf
- Certificate - LMT100 & LMT200 | Kazakhstan Metrology | PMU Warminster EN & RU pdf
- Certificate - LMT100 & LMT200 | PESO Exd | EN | Warminster pdf
- Certificate - LMT100 & LMT200 HART | INMETRO DNV 18.0080 | PMU Warminster & Shanghai pdf
- Certificate - SIL CERT 968 FSP 1559.00 18 LMT100 LMT200 LMT300 HART (PMU Warminster & Shanghai) pdf
- LTM100 and LMT200 FF Registration Certificate pdf
- LTM100 and LMT200 Magnetostrictive level transmitter certificate pdf
- Certificate - LMT Series | NEPSI ex ia GYJ21.3372X | Shanghai & Warminster | expires 10.2026 pdf
- Certificate - LMT100 & LMT200 | PESO Exi | EN | Warminster pdf