Yodify Product Library
Instantly add the LMT200 External Mount Magnetostrictive Level Transmitter and 50,000+ more product series to your store or catalog
Book Your Demo and See How
or create your store
LMT200 External Mount Magnetostrictive Level Transmitter
Brand: ABB GroupThe LMT Series of level transmitters is a modular range of field mounted, advanced microprocessor-based electronic transmitters, utilizing multiple sensor technologies.
Accurate and reliable measurement of liquid level and interface are provided in even the most difficult and hazardous industrial environments.
Features- Calibrated from the factory
- High Accuracy: 0.01% of Full Scale or ±1.27 mm
- Never Requires Re-Calibration: Set It & Forget It
- Easy setup with waveform display
- Not affected by agitation, foam or emulsion layers
- No oscilloscope required
- Designed to Mount Externally to K-TEK KM26 or other
- Magnetic Level Gauge
- Superior Sensor (Patent #5,473,245)
- Local Indication with HMI Display
- Dual Compartment Housing with Separate Field Terminal Compartment
- Loop Powered to 15.24 m (50 ft) Probe Length
- Total and/or Interface Level Measurement
- Temperature Range: -195.5° to 426.6° C (-320° to 800° F) with options
- Field Replaceable / Upgradable Electronics Module
- Built-in RFI / EMI Filter
- Digital Communications
- Online Self-verification
- Options:
- Two Level Indications
- Glass Viewing Window
- 316 Stainless Steel Enclosure
- Built-in surge protection
1 - 12 of 720 Part Numbers
LMT200.B4.S6.C1.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.B2.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Right Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C1.T1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121° C (–320° to 250 °F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Top Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D1.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D2.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Aluminum with 2 x NPT 1/2"
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
LMT200.B4.S6.C3.B1.D3.L2.H1-CS.SEH.TS.SC2.S1.STH.AV//GD1.M5.R3.
- Approvals - INMETRO, ATEX/IECEx Flameproof, Intrinsically Safe, No–sparking (Protection Type Marked by Customer)
- Probe Material - 316/L SS
- Probe Style and Probe Type - 3/4" NPS Sensor Well with 5/8" Rigid Probe for Cryogenic Services, –195.55° to 121.11° C (–320° to 250° F), with N2 Purge. See Temperature Chart for Full Selection Detail*
- Mounting Orientation - Bottom Left Connected Electronic Housing
- Housing - Stainless Steel with 2 x M20 x 1.5
- Display - With Through the Glass (TTG) Push Buttons, Display and Glass Cover
- Output - Single 4-20 mA + HART
- SIL Certification - SIL2 (HFT=0) and SIL3 (HFT=1) – Certified Acc. to IEC61508
- Sensor Probe Options - 90 Degree Bend Housing Extension (Maximum Probe Length 7.62 m/25 ft)
- Device Identification Plate - Add Stainless Steel Hang Tag, Custom Markings 4 Lines, 22 Characters Per Line
- Signal Cable Length - 10 m (Approx. 33 ft)
- Surge Protector - Surge/Transient Protector
- Special Other - Special Paint or Treatment on Housing
- Mounting Accessories - Mounted to Chamber with Vibration Isolators, Minimum 2 Assemblies and Additional Assemblies Per Additional 5 ft of Probe Length
- Certificate - None
- Drawings - Drawings for Approval Required Prior to Construction
- Documentation Language - English
- Calibration and Configuration - 3–point Calibration Verification Certificate, Default Values of 100, 50 and 0% of Span, or Customer Specified Points
- Measuring Length - Customized Insertion Length in inches
1 - 12 of 720 Part Numbers
Specifications
Brand
Accuracy
- ± 0.01 % of Full Scale or ± 1.27 mm, Whichever is Greater
Repeatability
- ± 0.005 % of Full Scale or 0.315 mm (0.012 in), Whichever is Greater
Non-Linearity
- ± 0.01 % of Full Scale or 0.86 mm (0.034 in), Whichever is Greater
Measuring Span
- Minimum 76.2 mm (3.0 in)
Process Pressure
- Up to 165.48 bar (2,400 psig)
- Standard -1 to 124.1 bar (-14.7 to 1,800 psig)
Process Temperature
- -195.5° to 426.6° C (-320° to 800° F)
Communication
- FOUNDATION Fieldbus
- HART
Enclosure/Body Material
- Enclosure: Cast Low Copper Aluminum with Powder Coat
- Enclosure: 316/L Stainless Steel
Supply Voltage
- 9.0-32 Vdc for FOUNDATION Fieldbus
- 12-43 Vdc for 4-20 mA HART Loop Powered
Ambient Temperature
- -40° to 85° C (-40° to 185° F)
Humidity
- 0 to 100 % Relative Humidity
Remote Transmitter
- Standard Remote Distances of 5 m (16 ft), 10 m (33 ft), 20 m (66 ft), 30 m (98 ft)
Environmental Protection
- IP66, NEMA 4X
Certifications & Approvals
- SIL 2/3
- FM
- KOSHA
- EAC
- ATEX/IECEx
- NEPSI
- INMETRO
Material of Construction
- Sensor Tube: 316/L Stainless Steel
Probe Length
- 304.8 mm to 15.24 m (1 to 50 ft)
- 90 Degree Probes (SEH Option) 304.8 mm to 7.62 m (1 to 25 ft)
Mounting
- Stainless Steel Clamps for KM26 Magnetic Level Gauge Chamber Included, Optional Vibration Isolation Mounts
Electrical Connection
- Two M20 x 1.5 or Two 1/2” FNPT, Adapters and Bus Connectors Also Available
Damping
- Field Adjustable 0.1 to 60 s
- Oil & Gas
- Chemicals
- Refineries
- Power Generation
Documentation
Data Sheets
- Version matrix - LMT | Magnetostrictive Technical description pdf
- Driver LMT Magnetostrictive FF LMT100, LMT200, LMT300 Level Transmitter Technical Description pdf
- Driver LMT Magnetostrictive HART Supplement Info Driver pdf
- LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER data sheet pdf 13.1 MB
Product Manuals
- LMT Series Magnetostrictive level transmitter LMT100 & 200 models Commissioning Instructions pdf
- LMT Series Magnetostrictive level transmitter LMT100 & 200 models Operating Instructions-Hart.pdf
- LMT Series Safety manual for magnetostrictive level transmitter safety manual pdf
- LMT100 and LMT200 Magnetostrictive level transmitters Foundation Fieldbus operation instruction pdf
Bulletin
Certifications
- Certificate - ATEX IS FM17ATEX0062X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - ATEX nA ic FM17ATEX0063X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - ATEX XP FM17ATEX0064X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - CRN | LMT100 (PMU Warminster) pdf
- Certificate - FMC FM17CA0124X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - FMUS XP IS FM17US0243X | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - IECEx XP IS FME 17.0004X 1 | LMT100 LMT200 HART FF PA (PMU Warminster & Shanghai) pdf
- Certificate - LMT | Registration 1A9D Device 02 HART pdf
- Certificate - LMT 100 & LMT200 | Registration FDI 01.00.00 HART pdf
- Certificate - LMT Series | NEPSI Ex d GYJ21.3373X | Shanghai & Warminster | expires 10.2026 pdf
- Certificate - LMT Series | NEPSI nA ic GYJ21.3374X | Shanghai & Warminster | expires 10.2026 pdf
- Certificate - LMT100 & LMT200 | EAC EMC | EN & RU pdf
- Certificate - LMT100 & LMT200 | EAC Ex | EN & RU | Warminster pdf
- Certificate - LMT100 & LMT200 | Kazakhstan Metrology | PMU Warminster EN & RU pdf
- Certificate - LMT100 & LMT200 | PESO Exd | EN | Warminster pdf
- Certificate - LMT100 & LMT200 HART | INMETRO DNV 18.0080 | PMU Warminster & Shanghai pdf
- Certificate - SIL CERT 968 FSP 1559.00 18 LMT100 LMT200 LMT300 HART (PMU Warminster & Shanghai) pdf
- LTM100 and LMT200 FF Registration Certificate pdf
- LTM100 and LMT200 Magnetostrictive level transmitter certificate pdf
- Certificate - LMT Series | NEPSI ex ia GYJ21.3372X | Shanghai & Warminster | expires 10.2026 pdf