Model ASL Low Differential Pressure Transducer

Brand: Setra Systems, Inc

Setra’s Model ASL is the highest accuracy transducer for measuring low differential pressure in the AccuSense product line.

Its ±0.07% of Full Scale accuracy is calibrated using the "End Point Method" which improves linearity when compared to competitive transducers, which use the "Best Fit Straight Line Method" of calibration.

The ASL's calibration is tamper proof by utilizing a SecureCal calibration key which eliminates inadvertent adjustments, while allowing authorized users to adjust the sensor's calibration coefficients for a true sensor calibration.

The design of the ASL offers class leading overpressure capability and multiple pressure and electrical fittings to accommodate a wide range of applications.

Specifications

Accuracy

  • RSS: < ± 0.07 % of Full Scale

Applications

  • Exhaust Pressure
  • Filter Pressure
  • Industrial High Accuracy
  • Leak Detection Systems
  • Medical Instrumentation
  • Part Integrity Testing
  • Tests Stands
  • Wind Tunnels Measurement

Approvals & Certifications

  • CE
  • RoHS

Burst Pressure

  • psi: 0 to 300 (kPa: 0 to 2,000, bar: 0 to 20)

Cable Length

  • 3 feet (1 metre)

Circuit Protection

  • Miswiring: Reverse Excitation Protection

Consumption

  • Current Consumption: < 23 mA (5 Vdc & 10 Vdc Versions)

Electrical Connectors

  • 6-Conductor Shielded Cable
  • 6-Pin Male Bayonet Connector

Enclosure, Body Material

  • Stainless Steel

Environmental Protection

  • IP65
  • IP66
  • NEMA 4X

Excitation Voltage

  • 15-30 Vdc (10 Vdc Output)
  • 9-30 Vdc (5 Vdc & 4-20 mA Output)

Hysteresis

  • < ± 0.03 % of Full Scale

Line Pressure

  • Maximum

Line Pressure Effect

  • 2 % of Full Scale / psig: 100 (kPa: 689.5, bar: 6.895)

Materials of Construction

  • 630 Stainless Steel

Media

  • Dry Gas

Non-Linearity

  • End Point: < ± 0.03 % of Full Scale

Non-Repeatability

  • < ± 0.02 % of Full Scale

NPT Connection

  • 1/8” NPT Female
  • 1/8” NPT Male

Operating Temperature

  • -40° to 85° C (-40° to 124° F)

Output

  • Signal Output: 0-10 Vdc, 4-Wire
  • Signal Output: 0-5 Vdc
  • Signal Output: 4-20 mA, 2-Wire

Pressure Range

  • Inches WC: 0 to 40
  • mbar: 0 to 100
  • psi: 0 to 1

Response Time

  • < 10 milliseconds for Voltage Output
  • < 100 milliseconds for Current Output

SAE Connection

  • 7/16”-20 SAE Male

Stability

  • Long Term Stability: < 0.15 % of Full Scale Per Year

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Temperature Effect

  • Thermal Total Error Band: < ± 0.25 % of Full Scale - Typical
  • Thermal Total Error Band: < ± 0.5 %, Max.

Temperature Range

  • Temperature Calibrated: -20° to 60° C (-4° to 140° F)

Tolerance

  • Span Setting Tolerance & Zero Offset Tolerance: < ± 0.1 % of Full Scale - Typical

Update Time

  • Within ± 0.02 % of Full Scale after 15 minutes

Zero Offset

  • Zero Offset Positive Effect: < 0.1 %/G
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more