Yodify Product Library
Instantly add the OEM Oxygen Transmitter EMD-485D/485M/482D and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

OEM Oxygen Transmitter EMD-485D/485M/482D

Brand: Southland Sensing Ltd

he EMD-485D/485M/482D oxygen transmitter is designed primarily for OEM users who are looking to integrate this unit into a larger system such as an Inert Glovebox System or Nitrogen / Oxygen generator.  

This unit is also popular among universities due to its low cost and ease of use.

The OEM platform is configurable for Trace, Percent or Purity applications and comes with a variety of sensor, sensor housing options and electronics options. 

 The enclosure is designed for indoor installations.

The analyzer comes factory selected to one of the following ranges: 0 – 10 ppm, 0 – 100 ppm, 0 – 1000 ppm, 0 – 1 %, 0 – 5%, 0 – 10%, 0 – 25%, 0 – 100%.  

A second range is loaded via toggle switch to allow for ambient air calibration.

The oxygen sensor is based on the galvanic electrochemical fuel cell principal and is manufactured in house under a strict quality procedure.  

The sensors are self contained and minimal maintenance is required – no need to clean electrodes or add electrolyte.  

The precision sensors offer excellent performance, accuracy and stability while maximizing the expected life.

The unit can be configured for 2-wire loop applications (12 – 24V DC Loop), 6-wire applications (12 – 24V DC Input, 4 – 20mA, 0 – 1V DC and 0 – 10V DC output) or MODBUS ASCII.
Features
  • Well Suited for OEM Installations
  • Precision Fuel Cell Oxygen Sensor Technology
  • Trace or Percent Configuration
  • Measure Oxygen from 0.1ppm to 100%
  • 4 - 20mA, 0 - 1V DC, 0 - 10V DC Outputs
  • Updated Microprocessor Based Design
  • Cost Effective, Compact & Low Maintenance
  • Bi-Directional RD485 MODBUS ASCII
  • Updated Microprocessor Based Design
  • Seamlessly integrates with PLC & DCS Systems

1 - 3 of 3 Part Numbers
EMD-482
EMD-482
OEM Oxygen Transmitter, 2-wire loop
EMD-485
EMD-485
OEM Oxygen Transmitter, 6-wire
EMD-485M
EMD-485M
OEM Oxygen Transmitter, 6-wire, MODBUS RS485 ASCII
1 - 3 of 3 Part Numbers

Specifications

Accuracy

  • < 1 % Full Scale Range

Calibration

  • 2 - 3 months or as needed

Classification

  • General Purpose

Dimensions (PCB)

  • 3.25 x 2.00 inch

Display

  • Optional

Temperature

  • 0° to 50° C

Temperature Compensation

  • Integral

Output

  • EMD-482: 4-20 mA
  • EMD-485M: 4-20 mA, 0-1 Vdc, 0-10 Vdc

Sensor Housing

  • Optional, H6 or H3

Flow Sensitivity

  • 0.5 - 5.0 SCFH

Sensor Type

  • Precision Fuel Cell

Warranty

  • 12 Months Sensor
  • 12 Months Electronics

  • Inert Glove Box Systems 
  • Nitrogen and O2 PSA Generators 
  • Laboratories & Universities 
  • Beverage Grade CO2 Monitoring 
  • Air Separation Plants & Many Others

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more