Brand: R. STAHL AG

Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
Features
  • Corrosion-resistant, GRP Ex d enclosure
  • Max sound output 115 dB(A) @ 1 m
  • 2 stage alarm, independently selectable 2nd stage
  • Each with 32 selectable tones in accordance with international regulations
  • Independent tone selection using a DIL switch for each pitch
  • IP66 rated as standard
  • Monitoring facility (DC voltages only)

1 - 12 of 16 Part Numbers
205206
205206
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.300 A
  • Rated operational voltage DC - 24.00 - 24.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0191 X
  • ATEX gas certificate - Baseefa 08 ATEX 0191 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIB T6 Gb
  • Gas explosion protection IECEx - Ex d IIB T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0062X
  • IECEX gas certificate - IECEx BAS 08.0062X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/B-D-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/B-D-EN-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205207
205207
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.160 A
  • Rated operational voltage DC - 48.00 - 48.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0191 X
  • ATEX gas certificate - Baseefa 08 ATEX 0191 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIB T6 Gb
  • Gas explosion protection IECEx - Ex d IIB T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0062X
  • IECEX gas certificate - IECEx BAS 08.0062X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/B-F-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/B-F-EN-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205208
205208
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.045 A
  • Rated operational voltage AC - 230.00 - 230.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0191 X
  • ATEX gas certificate - Baseefa 08 ATEX 0191 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIB T6 Gb
  • Gas explosion protection IECEx - Ex d IIB T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0062X
  • IECEX gas certificate - IECEx BAS 08.0062X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/B-N-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/B-N-EN-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205209
205209
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.300 A
  • Rated operational voltage DC - 24.00 - 24.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-D-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/C-D-EN-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205214
205214
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.045 A
  • Rated operational voltage AC - 230.00 - 230.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-N-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/C-N-EN-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205216
205216
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.045 A
  • Rated operational voltage AC - 230.00 - 230.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-N-EN-RN-ME-00-00-00
  • Title Product Variant Technical Data - YA90/C-N-EN-RN-ME-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205217
205217
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.045 A
  • Rated operational voltage AC - 230.00 - 230.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificate EAC - TS RU S-DE.AA71.B.00033
  • Certificates - EAC (TehnoP), India (PESO), Russian Federation (TPB SER)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T85 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection EAC - 1 Ex d IIC T6 Gb X
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-N-RU-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/C-N-RU-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205365
205365
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +66 °C
  • Ambient temperature max. - +66 °C
  • Ambient temperature min. - -60 °C
  • Service temperature max. - +66 °C
  • Service temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 2x1/2"NPT adaptor M20x1/2"NPT
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.500 A
  • Rated operational voltage DC - 24.00 - 24.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 66 °C
  • Application range (zones) - 1, 2, 21, 22
  • Certificates - Canada / USA (UL), India (PESO)
  • Languages of the documentation - English, German
  • NEC 500 gas explosion protection - Class I, Div. 2,
  • NEC 500 zones - Class I, Div. 2
  • NEC 500_2 gas explosion protection - Group A,B,C,D
  • NEC 502 gas explosion protection - Class II, Div. 2
  • Zone NEC 500_2 - Class II, Div. 2

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-D-UL-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/C-D-UL-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
205366
205366
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +66 °C
  • Ambient temperature max. - +66 °C
  • Ambient temperature min. - -60 °C
  • Service temperature max. - +66 °C
  • Service temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 2x1/2"NPT adaptor M20x1/2"NPT
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.130 A
  • Rated operational voltage AC - 115.00 - 115.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 66 °C
  • Application range (zones) - 1, 2, 21, 22
  • Certificates - Canada / USA (UL), India (PESO)
  • Languages of the documentation - English, German
  • NEC 500 gas explosion protection - Class I, Div. 2,
  • NEC 500 zones - Class I, Div. 2
  • NEC 500_2 gas explosion protection - Group A,B,C,D
  • NEC 502 gas explosion protection - Class II, Div. 2
  • Zone NEC 500_2 - Class II, Div. 2

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-L-UL-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/.-.-UL
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
206661
206661
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.300 A
  • Rated operational voltage DC - 24.00 - 24.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificate EAC - TS RU S-DE.AA71.B.00033
  • Certificates - EAC (TehnoP), India (PESO), Russian Federation (TPB SER)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection EAC - Ex tb IIIC T85 °C Db X
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection EAC - 1 Ex d IIC T6 Gb X
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-D-RU-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/C-D-RU-RN-ST-00-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
206770
206770
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.080 A
  • Rated operational voltage AC - 115.00 - 115.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-L-EN-RN-ST-00-00-00
  • Title Product Variant Technical Data - YA90/.-.-EN
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Weight - 4.500 kg
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
211497
211497
R. STAHL Audible Signalling Device Sounder in Flameproof Enclosure
Corrosion-resistant, GRP Ex d enclosure

Max sound output 115 dB(A) @ 1 m

2 stage alarm, independently selectable 2nd stage

Each with 32 selectable tones in accordance with international regulations

Independent tone selection using a DIL switch for each pitch

IP66 rated as standard

Monitoring facility (DC voltages only)

Acoustic Data

  • Pitch - 2
  • Sound pressure level - max. 115 dB(A) @ 1m
  • Tone selection - via DIL switch

Ambient Conditions

  • Ambient temperature - -60 °C ... +60 °C
  • Ambient temperature max. - +60 °C
  • Ambient temperature min. - -60 °C

Components

  • Drilled holes - 2 x M20
  • Screw connections - Can be ordered as accessories
  • Stopping plug - 1 x M20 x 1.5, 1 x dust cap
  • Stopping plug material - Brass

Electrical Data

  • Rated operational current - 0.300 A
  • Rated operational voltage DC - 24.00 - 24.00 V
  • Tolerance - -10.0 - 10.0 %

Explosion Protection

  • Ambient temperature °C - -60 - 60 °C
  • Application range (zones) - 1, 2, 21, 22
  • ATEX dust certificate - Baseefa 08 ATEX 0189 X
  • ATEX gas certificate - Baseefa 08 ATEX 0189 X
  • Certificates - ATEX (BAS), Brazil (ULB), China (CQST), IECEx (BAS), India (PESO), Korea (KGS)
  • Dust explosion protection ATEX - II 2 D Ex tb IIIC TT85 °C Db
  • Dust explosion protection IECEx - Ex tb IIIC TT85 °C Db
  • Gas explosion protection ATEX - II 2 G Ex d IIC T6 Gb
  • Gas explosion protection IECEx - Ex d IIC T6 Gb
  • IECEX dust certificate - IECEx BAS 08.0061X
  • IECEX gas certificate - IECEx BAS 08.0061X
  • Languages of the documentation - English, German

General

  • Functional Description - Yodalex range Directional audible signal designed for use in hazardous or harsh environments.
  • Highlights - Corrosion-resistant, GRP Ex d enclosure Max sound output 115 dB(A) @ 1 m 2 stage alarm, independently selectable 2nd stage Each with 32 selectable tones in accordance with international regulations Independent tone selection using a DIL switch for each pitch IP66 rated as standard Monitoring facility (DC voltages only)
  • Product Description - Audible signalling device Sounder In flameproof enclosure
  • Product Type - YA90/C-D-EN-RN-ST-TL-00-00
  • Title Product Variant Technical Data - YA90/C-D-EN-RN-ST-TL-00-00 Sounder
  • WebCode - YA90A

Mechanical Data

  • Degree of protection IP (IEC 60529) - IP66
  • Enclosure colour - red (RAL 3001)
  • Enclosure material - Polyester (GRP), Glass fibre reinforced
  • Height - 210.000 mm
  • Length - 210.000 mm
  • Material mounting parts - 1.4404 stainless steel
  • Trumpet material - ABS, flame retardant
  • Width - 325.000 mm

Mounting / Installation

  • Connection type - Screw terminal
1 - 12 of 16 Part Numbers

Documentation

Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more