Yodify Product Library
Instantly add the Reversing Starter Max. 7.5 kW / 400 V Series 8510 and 50,000+ more product series to your store or catalog  
Book Your Demo and See How
or create your store

Reversing Starter Max. 7.5 kW / 400 V Series 8510

Brand: R. STAHL AG

The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. 

This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. 

It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
Features
  • Type-tested standard components
  • For outputs up to 7.5 kW/400 W
  • Corrosion-resistant enclosure material
  • Combined device results in minimized wiring expenditure

1 - 9 of 9 Part Numbers
145881
145881
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-..0
  • Title Product Variant Technical Data - 8510/132-08-334-..0 cont.-type rever
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217766
217766
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 24 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-010
  • Title Product Variant Technical Data - 8510/132-08-334-010 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217767
217767
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 42 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-020
  • Title Product Variant Technical Data - 8510/132-08-334-020 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217768
217768
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 110 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-030
  • Title Product Variant Technical Data - 8510/132-08-334-030 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217769
217769
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 500 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-060
  • Title Product Variant Technical Data - 8510/132-08-334-060 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217770
217770
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 230 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-130
  • Title Product Variant Technical Data - 8510/132-08-334-130 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217771
217771
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 240 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-140
  • Title Product Variant Technical Data - 8510/132-08-334-140 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217772
217772
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 400 V AC 50/60 Hz
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-160
  • Title Product Variant Technical Data - 8510/132-08-334-160 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
217773
217773
R. STAHL Reversing Starter Combination
Type-tested standard components



For outputs up to 7.5 kW/400 W



Corrosion-resistant enclosure material



Combined device results in minimised wiring expenditure

Ambient Conditions

  • Ambient temperature - -20 °C ... +40 °C
  • Ambient temperature max. - +40 °C
  • Ambient temperature min. - -20 °C

Electrical Data

  • Auxiliary contacts - 4 (4 NO)
  • Main contacts - 3-pole (3 NOs)
  • Rated actuating voltage - 24 V DC
  • Switching capacity - 7,5 kW / 400 V

Explosion Protection

  • Application range (zones) - 1, 2
  • ATEX firedamp certificate - DMT 00 ATEX E 073 U
  • ATEX gas certificate - DMT 00 ATEX E 073 U
  • Certificates - ATEX (BVS), Brazil (ULB), Canada (FM), IECEx (BVS), USA (FM)
  • Firedamp protection ATEX - I M2 Ex de I
  • Firedamp protection IECEx - Ex de I
  • Gas explosion protection ATEX - II 2 G Ex de IIC
  • Gas explosion protection IECEx - Ex de IIC
  • IECEx firedamp certificate - IECEx BVS 07.0029U
  • IECEX gas certificate - IECEx BVS 07.0029U

General

  • Functional Description - The R. STAHL Series 8510 relay reversing contactor is a type-tested standard component which switches outputs in accordance with AC3. This module is available in outputs up to 7.5 kW and is designed for voltages up to 400 V. It can be fitted in Ex e enclosures using an anti-vibration screw connection, easily accessible terminals simplify installation.
  • Highlights - Type-tested standard components For outputs up to 7.5 kW/400 W Corrosion-resistant enclosure material Combined device results in minimised wiring expenditure
  • Product Description - Reversing starter combination
  • Product Type - 8510/132-08-334-210
  • Title Product Variant Technical Data - 8510/132-08-334-210 Reversing contactor
  • WebCode - 8510I

Mechanical Data

  • Connection terminals finely-stranded max. - 6.00 mm²
  • Connection terminals min. - 1.50 mm²
  • Connection terminals of auxiliary contact finely stranded max. - 1.50 mm²
  • Connection terminals of auxiliary contact min. - 0.75 mm²
  • Connection terminals of auxiliary contact solid max. - 2.50 mm²
  • Connection terminals solid max. - 10.00 mm²
  • Degree of protection (IP) - IP20
  • Depth - 168.000 mm
  • Enclosure material - Epoxy resin
  • Height - 130.000 mm
  • Type of connection cable - Finely stranded, solid
  • Weight - 2.900 kg
  • Width - 115.000 mm
1 - 9 of 9 Part Numbers
Instantly populate your store or catalog 
CREATE YOUR SITE
or book a demo with the Yodify Team
show more